Pediatr Rheumatol Online J
August 2021
Background: To describe a case of pediatric sarcoidosis which initially presented as papillary conjunctivitis before manifesting as bilateral lacrimal gland swelling without other known systemic involvement.
Case Presentation: A 10-year-old female presented to the pediatric ophthalmology clinic with complaints of bilateral eyelid swelling, tearing and itching for approximately 1 month. Her history and exam were most consistent with allergic conjunctivitis, for which she was started on a standard topical regimen.
Background: The recently released GoCheck Kids iPhone photoscreening app is designed to detect amblyopia risk factors (ARFs) in young children and includes remote review of images captured by smartphone. We aimed to evaluate the system's accuracy in detecting AAPOS guidelines ARFs.
Methods: Patients 6 months through 6 years of age at Medical University of South Carolina were recruited for this prospective study.
J Pediatr Ophthalmol Strabismus
March 2018
Purpose: The GoCheck Kids smartphone photoscreening app (Gobiquity Mobile Health, Scottsdale, Arizona, USA), introduced in 2014, is marketed to pediatricians with little published validation. We wished to evaluate the GoCheck Kids Screener for accuracy in detecting amblyopia risk factors (ARF) using 2013 American Association for Pediatric Ophthalmology and Strabismus guidelines.
Design: Validity assessment.
Purpose: To determine whether the Spot Vision Screener effectively detects amblyopia risk factors (ARFs) in patients with developmental disability using the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS).
Methods: Children with developmental disability presenting for complete pediatric ophthalmologic examination were prospectively enrolled between June 2012 and March 2016. The following data were analyzed: presence of ARFs according to the AAPOS guidelines, refraction, eye alignment, and other ocular pathology.
Purpose: To evaluate the use of the Spot Vision Screener (Spot; Welch Allyn, Skaneateles Falls, New York, USA) for detection of amblyopia risk factors in children aged 6 months to 3 years, as defined by the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus.
Design: Reliability analysis.
Methods: In this study, children seen from June 1, 2012, to April 30, 2016 were tested with the Spot during a routine visit.
J Pediatr Ophthalmol Strabismus
May 2017
Purpose: To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population.
Methods: Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings.
Background: The Spot Vision Screener, a new automated screener designed for use in schools and pediatric offices, refers children for strabismus based on the device's measurement of "gaze." We sought to evaluate its ability to detect manifest strabismus of ≥8(Δ) in primary position, which criteria is specified by the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus for detection of amblyopia risk factors by automated vision screeners.
Methods: In this prospective study, new and returning patients seen in the pediatric ophthalmology clinic underwent screening with the Spot Vision Screener (version 1.
Purpose: To evaluate the updated Spot Vision Screener (PediaVision, Welch Allyn, Skaneateles Falls, NY) in detecting amblyopia risk factors using 2013 guidelines of American Association for Pediatric Ophthalmology and Strabismus (AAPOS).
Methods: In this prospective study, patients seen from June 2012 to November 2013 were tested with the Spot prior to examination by a pediatric ophthalmologist who was masked to test results. The following data were analyzed: age, subject testability, examination findings, and systemic and ocular pathology.
Background And Purpose: The double Maddox rod is a commonly used instrument to test for cyclotorsion in the clinical setting. This paper assesses the ability of patients without torsional complaint to accurately demonstrate torsional status with varying degrees of induced hypertropia as tested by double Maddox rod.
Methods: Thirty-seven orthophoric subjects underwent double Maddox rod testing with vertical prism of 3(Δ), 10(Δ), 16(Δ), 20(Δ), and 30(Δ).
Purpose: To compare refractive data and testability of Spot (PediaVision) and Plusoptix A09 (Plusoptix, Inc) photoscreeners and to compare each device with traditional cycloplegic retinoscopy.
Design: Prospective, interventional case series.
Methods: After informed consent, patients underwent testing with the Spot and Plusoptix photoscreeners before their examination by a pediatric ophthalmologist masked to the results.