Purpose: Contrast-enhanced CT (CECT) may be performed immediately following microwave liver ablation for assessment of ablative margins. However, practices and protocols vary among institutions. Here, we compare a standardized bolus-tracked biphasic CECT protocol and compare this with a single venous phase fixed delay protocol for ablation zone (AZ) assessment.
View Article and Find Full Text PDFRationale And Objectives: Intratumoral heterogeneity means single site tumor biopsy might not be representative. Here we develop and optimize an MRI-informed robotic multiregional 'smart' biopsy technique in retroperitoneal and pelvic sarcomas (RPS). We also explore the relationship between imaging and histological biomarkers.
View Article and Find Full Text PDFBackground: Directly-injected therapies (DIT) include a broad range of agents within a developing research field in cancer immunotherapy, with encouraging clinical trial results in various tumour subtypes. Currently, the majority of such therapies are only available within clinical trials; however, more recently, talimogene laherparepvec (T-VEC, Imlygic) has been approved as the first oncolytic virus therapy in the USA and Europe. Our institution contributes to multiple different trials exploring the efficacy of DIT, the majority of which are performed by oncologists in clinic.
View Article and Find Full Text PDFRectal tumors extending beyond the total mesorectal excision (TME) plane (beyond-TME) require particular multidisciplinary expertise and oncologic considerations when planning treatment. Imaging is used at all stages of the pathway, such as local tumor staging/restaging, creating an imaging-based "roadmap" to plan surgery for optimal tumor clearance, identifying treatment-related complications, which may be suitable for radiology-guided intervention, and to detect recurrent or metastatic disease, which may be suitable for radiology-guided ablative therapies. Beyond-TME and exenterative surgery have gained acceptance as potentially curative procedures for advanced tumors.
View Article and Find Full Text PDFPurpose: This study aimed to assess the image quality of apparent diffusion coefficient (ADC) maps derived from conventional diffusion-weighted MRI and fractional intracellular volume maps (FIC) from VERDICT MRI (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) in patients from the INNOVATE trial. The inter-reader agreement was also assessed.
Methods: Two readers analysed both ADC and FIC maps from 57 patients enrolled in the INNOVATE prospective trial.
Aberrant glycosylation is a universal feature of cancer cells, and cancer-associated glycans have been detected in virtually every cancer type. A common change in tumour cell glycosylation is an increase in α2,6 sialylation of N-glycans, a modification driven by the sialyltransferase ST6GAL1. ST6GAL1 is overexpressed in numerous cancer types, and sialylated glycans are fundamental for tumour growth, metastasis, immune evasion, and drug resistance, but the role of ST6GAL1 in prostate cancer is poorly understood.
View Article and Find Full Text PDFInvest Radiol
December 2023
Objectives: Whole-body magnetic resonance imaging (WB-MRI) has been demonstrated to be efficient and cost-effective for cancer staging. The study aim was to develop a machine learning (ML) algorithm to improve radiologists' sensitivity and specificity for metastasis detection and reduce reading times.
Materials And Methods: A retrospective analysis of 438 prospectively collected WB-MRI scans from multicenter Streamline studies (February 2013-September 2016) was undertaken.
Int J Comput Assist Radiol Surg
October 2023
Purpose: Radiofrequency ablation (RFA) is a curative treatment option for small lung metastases, which conventionally involves multiple freehand manipulations until the treating electrode is satisfactorily positioned. Stereotactic and robotic guidance has been gaining popularity for liver ablation, although has not been established in lung ablation. The purpose of this study is to determine the feasibility, safety, and accuracy of robotic RFA for pulmonary metastases, and compare procedures with a conventional freehand cohort.
View Article and Find Full Text PDFPurpose: To compare the results of a novice with those of experienced interventional radiologists (IRs) for stereotactic radiofrequency ablation (SRFA) of malignant liver tumors in terms of safety, technical success, and local tumor control.
Methods: A database, including all SRFA procedures performed in a single center between January 2011 and December 2018 was retrospectively analyzed. A total of 39 ablation sessions performed by a novice IR were compared to the results of three more experienced IRs.
Prostate cancer is the most common cancer in men and it is estimated that over 350,000 men worldwide die of prostate cancer every year. There remains an unmet clinical need to improve how clinically significant prostate cancer is diagnosed and develop new treatments for advanced disease. Aberrant glycosylation is a hallmark of cancer implicated in tumour growth, metastasis, and immune evasion.
View Article and Find Full Text PDFBackground: Magnetic resonance imaging (MRI) can be used to target tumour components in biopsy procedures, while the ability to precisely correlate histology and MRI signal is crucial for imaging biomarker validation. Robotic MRI/computed tomography (CT) fusion biopsy offers the potential for this without in-gantry biopsy, although requires development.
Methods: Test-retest T1 and T2 relaxation times, attenuation (Hounsfield units, HU), and biopsy core quality were prospectively assessed (January-December 2021) in a range of gelatin, agar, and mixed gelatin/agar solutions of differing concentrations on days 1 and 8 after manufacture.
A shift in radiology to a data-driven specialty has been unlocked by synergistic developments in imaging biomarkers (IB) and computational science. This is advancing the capability to deliver "virtual biopsies" within oncology. The ability to non-invasively probe tumour biology both spatially and temporally would fulfil the potential of imaging to inform management of complex tumours; improving diagnostic accuracy, providing new insights into inter- and intra-tumoral heterogeneity and individualised treatment planning and monitoring.
View Article and Find Full Text PDFObjective: A commercially available CT-guided robot offers enhanced abilities in planning, targeting, and confirming accurate needle placement. In this short communication, we describe our first UK experience of robotic interventional oncology procedures.
Methods: We describe the device, discuss installation, operation, and report upon needle insertion success, accuracy (path deviation; PD and tip deviation; TD), number of adjustments, complications, and procedural success.
Purpose: To assess the technical outcome and local tumor control of multi-probe stereotactic radiofrequency ablation (SRFA) in a large series of patients. Furthermore, to determine factors accounting for adverse outcomes.
Material And Methods: Between 2003 and 2018, 865 patients were treated by SRFA for 2653 primary and metastatic liver tumors with a median tumor size of 2.
Background: Radiofrequency ablation (RFA) is subject to "heat-sink" effects, particularly for treatment of tumors adjacent to major vessels.
Methods: In this retrospective study, 104 patients with 137 tumors (40 HCC, 10 ICC and 54 metastatic liver tumors) close to (≤1 cm from) the hepatic venous confluence underwent stereotactic RFA (SRFA) between June 2003 and June 2018. Median tumor size was 3.
Multiparametric magnetic resonance imaging (mpMRI) of the prostate is used by radiologists to identify, score, and stage abnormalities that may correspond to clinically significant prostate cancer (CSPCa). Automatic assessment of prostate mpMRI using artificial intelligence algorithms may facilitate a reduction in missed cancers and unnecessary biopsies, an increase in inter-observer agreement between radiologists, and an improvement in reporting quality. In this work, we introduce AutoProstate, a deep learning-powered framework for automatic MRI-based prostate cancer assessment.
View Article and Find Full Text PDFThere are several forms of kava () products available for human consumption, and many factors are known to influence their chemical compositions and therefore their pharmacological properties. Because of the increased popularity of kava intake, a rigorous characterization of their content diversity is prerequisite, particularly due to its known potential to cause hepatotoxicity. To understand the composition diversity of kavalactones and flavokavains in commercial kava products, we developed a UPLC-MS/MS-based analytical method for the quantification of six kavalactones (kavain, dihydrokavain, methysticin, dihydromethysticin, yangonin and desmethoxyyangonin) and two flavokavains (flavokavains A and B) and analyzed their contents in 28 different kava products in the form of capsules, tinctures, traditional aqueous suspensions and dried powders.
View Article and Find Full Text PDFPurpose: To evaluate safety, local oncological control, long-term outcome and potential prognostic factors of stereotactic RFA (SRFA) for the treatment of BCLMs.
Methods: Between July 2003 and December 2019, 42 consecutive female patients with median age 54.0 years were treated with SRFA at our institution for 110 BCLMs in 48 ablation sessions.
Objectives: To assess the frequency of major complications after multi-probe stereotactic radiofrequency ablation (SRFA) in a large cohort of patients over 15 years and to elucidate risk factors for adverse events.
Materials And Methods: A retrospective study was carried out between July 2003 and December 2018. Seven hundred ninety-three consecutive patients (median 65.
Background: To evaluate the efficacy, safety and overall clinical outcome of multiprobe SRFA as a treatment for recurrent colorectal liver metastases after hepatic resection (HR).
Methods: A retrospective, single center study carried out between 2006 and 2018. 64 consecutive patients with recurrent or new CRLM after previous HR were treated by SRFA for 217 lesions (median size 2.