Biomed Instrum Technol
June 2019
Effective personal protective equipment (PPE) is critically important to preventing the spread of infectious diseases. Appropriate test systems and test soils are needed to adequately evaluate PPE. ASTM test method F903, which specifies the test method setup also used in ASTM F1670/F1670M-17a and ASTM F1671/F1671M-13, has been used for decades to test liquid penetration resistance of fabrics.
View Article and Find Full Text PDFPersonal protective equipment (PPE), such as gowns used in the latest Ebola outbreak in Western Africa, are critical in preventing the spread of deadly diseases. Appropriate test systems and test soils are needed to adequately evaluate PPE. ASTM F903, , has been used for decades to test fabrics' resistance to liquid penetration.
View Article and Find Full Text PDFBackground: One-way valves used in day use devices (used on multiple patients throughout a day without reprocessing between patients) are intended to reduce the potential for cross-contamination between patients resulting from the backflow of patient fluids. One-way valves are typically designed to withstand high levels of back pressure before failure; however, they may not be explicitly designed as a means of infection control as used in medical device applications.
Methods: Five different medical grade one-way valves were placed in low pressure configurations.
Unlabelled: Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices.
View Article and Find Full Text PDFCardiovasc Ultrasound
July 2012
Background: Ultrasound (US) imaging can be enhanced using gas-filled microbubble contrast agents. Strong echo signals are induced at the tissue-gas interface following microbubble collapse. Applications include assessment of ventricular function and virtual histology.
View Article and Find Full Text PDFThe objective of this study was to establish a reasonably simple and reliable method to measure very low concentrations of polyhexamethylene biguanide (PHMB) in multipurpose contact lens solutions (MPSs). By using a weak cation exchange solid phase extraction cartridge to extract the PHMB from MPS, followed by HPLC analysis using an evaporative light scattering detector, low levels (0.1 ppm) of PHMB were detected.
View Article and Find Full Text PDFCount sheets, when placed in contact with surgical instruments during steam sterilization, can transfer ink to the instruments. To explore whether this poses a safety concern, stainless steel instruments were placed on top of completely inked paper and subjected to steam sterilization, extracted, and tested for cytotoxicity. Preprinted labels were examined in a similar fashion.
View Article and Find Full Text PDF