Materials (Basel)
November 2023
Statement Of Problem: The extraction of fractured abutment screws can be a difficult challenge to overcome.
Purpose: To compare the removal capacity, dental implant connection damage, and time required to remove the fractured abutment screws between three drilling techniques and a conventional method.
Materials And Methods: A total of 180 prefabricated screw-retained abutments were intentionally fractured in internal connection dental implants after being subjected to a cyclic load and a static compression load.
J Clin Med
February 2023
Background And Purpose: Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology.
Methods: A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed.
Background: It is necessary to know the behavior of different attachment systems to be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de-insertion cycles) was determined , evaluating two overdenture attachment systems (Locator® and OT Equator®).
Material And Methods: The study used an implant replica compatible with the abutments of both systems.
Purpose: To quantify the rate of maintenance interventions of mandibular prostheses: complete dentures and overdentures retained by two implants, with either internal hex or external hex connections.
Materials And Methods: This study analyzed patients with edentulous mandibles treated with distinct treatment protocols: a control group received complete dentures; a second group received Locator-retained overdentures supported by two external hex connection implants; and a third group received overdentures supported by internal hex connection implants. All of the maintenance interventions associated with the prosthetic treatment after delivery were recorded (starting from 2000 until the final assessment in 2012).
Statement Of Problem: Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.
Purpose: The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.
Material And Methods: This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80).
Background: For implant-supported hybrid prostheses, high mastication forces and reduced acrylic resin thickness over a metal substructure often cause failures arising from tooth or resin fractures. To assay fracture resistance of artificial teeth and resin in implant-supported hybrid prostheses in relation to the titanium structure and retention design supporting teeth.
Material And Methods: 40 specimens bearing incisors were divided into four groups according to the titanium structure supporting the teeth and the type of load force applied: Group I (Control; n=10): Application of static loading to ten incisors set over a metal structure with internal retention.
Background: This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures).
Material And Methods: This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire.