Publications by authors named "Edson J L Moreira"

The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min.

View Article and Find Full Text PDF

The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group).

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the dentists' knowledge and practice regarding HIV positive individuals' oral care in Rio de Janeiro State.

Methods: Dentists from Rio de Janeiro State (n = 242) answered an electronic questionnaire on biosafety procedures, oral manifestations of AIDS, and knowledge of HIV infection. Collected information was stratified by gender, and data were analyzed using Chi-square and t tests.

View Article and Find Full Text PDF

The aim of the present study was to evaluate the cyclic fatigue of two anatomic finishing files: XP-Endo Finisher and XP-Clean. Roughness pattern and the micro-hardness of the files were also assessed. Instruments were subjected to cyclic fatigue resistance measuring the time to fracture in an artificial stainless-steel canal with a 60° angle and a 5-mm radius of curvature.

View Article and Find Full Text PDF

Objectives: This study aimed to compare four final irrigation protocols (passive ultrasonic irrigation [PUI], EndoVac, Self-Adjusting File [SAF] and EasyClean) on the removal of accumulated hard-tissue debris (AHTD) from mesial canals of mandibular molars through microcomputed tomographic (micro-CT) analysis.

Materials And Methods: Forty mesial roots of mandibular molars presenting isthmuses type I or III were scanned in a micro-CT device and instrumented up to Reciproc R40 instrument. After the completion of canal preparations, root canals of each group were submitted to a final rinse using 20 mL of solution (16 mL of 5.

View Article and Find Full Text PDF

Objectives: This study evaluated the amount of remaining root canal filling materials after retreatment procedures performed by undergraduate students using manual, rotary, and reciprocating techniques through micro-computed tomographic analysis. The incidence of instrument fracture and the instrumentation time were also evaluated.

Materials And Methods: Thirty maxillary single rooted teeth were prepared with Reciproc R25 files and filled with gutta-percha and AH Plus sealer by the continuous wave of condensation technique.

View Article and Find Full Text PDF

Objectives: To evaluate the cyclic fatigue using severely curved canals and torsional resistance of ProDesign R (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil), Reciproc Blue (VDW, Munich, Germany), and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating instruments MATERIALS AND METHODS: Twenty instruments of the ProDesign R (25/0.06) system, 20 instruments of the Reciproc Blue (25/0.08v) system, and 20 instrument of the WaveOne Gold (25/0.

View Article and Find Full Text PDF

Introduction: The aim of this randomized clinical trial was to evaluate the influence of rotary or reciprocating retreatment techniques on the incidence, intensity, duration of postoperative pain, and medication intake.

Methods: After power analysis calculations, 65 patients who needed endodontic retreatment were randomly assigned to 1 of 2 groups according to the instrumentation system used: Mtwo (VDW, Munich, Germany) or Reciproc (VDW). Retreatments were performed in a single visit by an endodontic specialist.

View Article and Find Full Text PDF

Purpose: To evaluate dentists' professional experience and knowledge of emergency management of tooth avulsion injuries in Rio de Janeiro, Brazil.

Materials And Methods: A total of 100 questionnaires were evaluated. The first part of the questionnaire consisted of questions regarding personal information.

View Article and Find Full Text PDF

Introduction: This study evaluated the influence of different features of canal curvature geometry on the number of cycles to fracture of a rotary nickel-titanium endodontic instrument subjected to a cyclic fatigue test.

Methods: BioRaCe BR4C instruments (FKG Dentaire, La Chaux-de Fonds, Switzerland) were tested in 4 grooves simulating curved metallic artificial canals, each one measuring 1.5 mm in width, 20 mm in total length, and 3.

View Article and Find Full Text PDF

Introduction: The aim of the present study was to assess the bond strength of root fillings in oval-shaped canals prepared with the self-adjusting file (SAF) system.

Methods: A careful specimen selection resulted in 2 equal groups, each consisting of 12 extracted mandibular canines with oval canals that had vital pulps before extraction. One group was subjected to the SAF protocol, and the other group underwent conventional protocol, which was the ProTaper system with syringe-needle irrigation.

View Article and Find Full Text PDF

Introduction: This study compared the torsional properties of 2 stainless steel endodontic pathfinding instruments: C-Pilot (VDW, Munich, Germany) and C(+) files (Maillefer/Dentsply, Ballaigues, Switzerland). Stainless steel conventional K-type instruments (KCC(+), VDW) were used as controls.

Methods: File sizes 10 were subjected to a torsional assay in clockwise rotation.

View Article and Find Full Text PDF

Objectives: This study evaluated the effects of curvature location along an artificial canal on cyclic fatigue (CF) of an Mtwo rotary instrument, verifying the number of cycles to fatigue fracture (NCF) and morphologic characteristics of the fractured instruments.

Study Design: CF testing of instruments was performed in artificial canals with curvature radii of 10 mm and arc lengths of 11 mm. Mtwo rotary instruments size 40, 0.

View Article and Find Full Text PDF

Introduction: This study evaluated the influence of electropolishing surface treatment on the number of cycles to fracture of BioRace rotary nickel-titanium endodontic instruments.

Methods: BioRace size BR5C instruments with or without electropolishing surface treatment were used in an artificial curved canal under rotational speed of 300 rpm until fracture. Fractured surfaces and the helical shafts of fractured instruments were analyzed by scanning electron microscopy (SEM).

View Article and Find Full Text PDF

Objective: This study evaluated the number of cycles to fracture of ProTaper Universal S2 instruments when subjected to static and dynamic cyclic fatigue tests.

Study Design: ProTaper Universal S2 instruments were used until fracture in an artificial curved canal under rotational speed of 300 rpm in either a static or a dynamic test model. Afterward, the length of the fractured segments was measured and fractured surfaces and helical shafts analyzed by scanning electron microscopy (SEM).

View Article and Find Full Text PDF

The purpose of this study was to evaluate the flexibility, shape, and surface finishing of stainless steel (SS) and nickel-titanium (NiTi) finger spreaders as well as to compare the load required to insert these spreaders along a gutta-percha point adapted to the apical segment of curved or straight artificial canals. Instrument flexibility was investigated by using a universal testing machine in the cantilever-flexibility test. Scanning electron microscopy (SEM) was used to examine the shape and surface finishing of different sizes of SS and NiTi finger spreaders.

View Article and Find Full Text PDF

Introduction: This in vitro study aimed to investigate the antibacterial effects of photodynamic therapy (PDT) with methylene blue (MB) or toluidine blue (TB) (both at 15 microg/mL) as a supplement to instrumentation/irrigation of root canals experimentally contaminated with Enterococcus faecalis.

Methods: Seventy extracted teeth had their root canals contaminated with an endodontic strain of E. faecalis for 7 days, instrumented with nickel-titanium instruments and irrigated either with 2.

View Article and Find Full Text PDF

Introduction: During the preparation of curved canals, rotary nickel-titanium (NiTi) instruments are subjected to cyclic fatigue, which can lead to instrument fracture. Although several factors may influence the cyclic fatigue resistance of instruments, the role of the rotational speed remains uncertain. This study was intended to evaluate the effects of rotational speed on the number of cycles to fracture of rotary NiTi instruments.

View Article and Find Full Text PDF

The present work evaluated the influence of the curved segment length of artificial root canals (the arc) and the number of cycles necessary to fracture engine-driven nickel-titanium endodontic instruments. ProTaper F3 25-mm files at 250 rpm were used in two artificial canals. The artificial canals were made of stainless steel with an inner diameter of 1.

View Article and Find Full Text PDF