This paper presents the development, analysis, and application of chirped fiber Bragg gratings (CFBGs) for dynamic and static measurements of beams of different materials in the single-cantilever configuration. In this case, the beams were numerically analyzed using the finite-element method (FEM) for the assessment of the natural frequencies and vibration modes of the beam for the dynamic analysis of the structural element. Furthermore, the static numerical analysis was performed using a load at the free end of the beam, where the maximum strain and its distribution along the beam were analyzed, especially in the region at which the FBG was positioned.
View Article and Find Full Text PDFThis paper presents the development, analysis and application of a fiber Bragg grating (FBG) array for two-dimensional (2D) shape reconstruction in a cantilever beam. The structural elements made of Pinus wood and Nylon 6.0 were numerically analyzed using the finite element method for the strain distribution when constant loading is applied at the free end of the beam.
View Article and Find Full Text PDFWhen a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection.
View Article and Find Full Text PDFIntroduction: The Polo da Alta Sorocabana Laboratory in Presidente Prudente, SP, in partnership with other research institutions, conducted studies related to bats from the western region of the State of Sao Paulo, Brazil. Thus, certain situations were investigated, including: a) isolation of the rabies virus from 2006 to 2008; b) identification of respective antigenic variants; and c) characterization of daytime shelters of Desmodus rotundus vampire bats.
Methods: Samples for examination originated from nonhematophagous bats forwarded to the laboratory and subjected to direct fluorescent antibody test and mouse inoculation test.
Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment.
View Article and Find Full Text PDFObjectives: The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length.
Material And Methods: Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation.
Using the monoclonal antibody technique, the Clinical and Molecular Virology Laboratory of the Institute of Biomedical Sciences of the University of São Paulo typed 18 rabies virus samples from non-hematophagous bats of several species from the region of Presidente Prudente, SP, Brazil. Among these samples, 15 (82.3%) were defined as variant 3 (compatible with samples isolated from Desmodus rotundus bats) and three (16.
View Article and Find Full Text PDFObjectives: In cantilevered implant-supported complete prosthesis, the abutments' different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis.
Material And Methods: A circular steel master cast with five perforations containing implant replicas (Theta 3.
Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. In this study, the many clinical variations present in an implant-supported prosthesis were analyzed by a 3-dimensional finite-element method. The anterior segment of a human mandible treated with 5 implants supporting a curved beam was created to perform the tests.
View Article and Find Full Text PDFA survey of the Trypanosoma vivax genome was carried out by the genome sequence survey (GSS) approach resulting in 1,086 genomic sequences. A total of 455 high-quality GSS sequences were generated, consisting of 331 non-redundant sequences distributed in 264 singlets and 67 clusters in a total of 135.5 Kb of the T.
View Article and Find Full Text PDF