Introduction: Up to one-third of ischemic strokes remained cryptogenic despite extensive investigations. Atrial fibrillation may be detected in a significant proportion of patients with embolic stroke of undetermined source, particularly after the introduction of implantable loop recorder in clinical practice.

Methods: We retrospectively included all the consecutive patients with embolic stroke of undetermined source referred to our units in the period November 2013 to December 2018 and in which an implantable loop recorder was positioned within 6 months from stroke event.

View Article and Find Full Text PDF

Introduction: Atrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO).

View Article and Find Full Text PDF

Tricuspid regurgitation is increasingly recognized as a clinically significant valvular condition. The role of multiple pacemaker and implantable cardiac defibrillator leads in distortion of the valve structure and the risk of trauma to the valve and subvalvular apparatus with lead extraction contribute to the development of tricuspid regurgitation (TR). There is a clinical imperative to better understand the optimal way to diagnose lead-related TR, risk factors for the development of TR, and optimal strategies to mitigate this problem.

View Article and Find Full Text PDF

Introduction: Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position.

View Article and Find Full Text PDF

The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement.

View Article and Find Full Text PDF

Background: Bileaflet mitral valve prolapse (biMVP) is associated with frequent ventricular ectopy (VE) and malignant ventricular arrhythmia. We examined the effect of mitral valve (MV) surgery on VE burden in biMVP patients.

Methods: We included 32 consecutive patients undergoing MV surgery for mitral regurgitation secondary to biMVP between 1993 and 2012 at Mayo Clinic who had available pre- and post-operative Holter monitoring data.

View Article and Find Full Text PDF

Purpose: Optimal atrial pacemaker lead position and fixation mechanism have not been determined with regard to effect on complications. We aimed to determine the association between atrial lead-related complications and varying atrial lead tip positions and lead fixation mechanisms.

Methods: All patients who underwent dual-chamber pacemaker implant between 2004 and 2014 were retrospectively reviewed for atrial lead tip position and fixation type.

View Article and Find Full Text PDF

Introduction: Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation.

View Article and Find Full Text PDF

Although great strides have been made in the areas of ventricular pacing, it is still appreciated that dyssynchrony can be malignant, and that appropriately placed pacing leads may ameliorate mechanical dyssynchrony. However, the unknowns at present include: 1. The mechanisms by which ventricular pacing itself can induce dyssynchrony; 2.

View Article and Find Full Text PDF

Introduction: The dominant location of electrical triggers for initiating atrial fibrillation (AF) originates from the muscle sleeves inside pulmonary veins (PVs). Currently, radiofrequency ablation (RFA) is performed outside of the PVs to isolate, rather than directly ablate these tissues, due to the risk of intraluminal PV stenosis.

Methods: In 4 chronic canine experiments, we performed direct PV muscle sleeve RFA ± postablation drug-coated balloon (DCB) treatment with paclitaxel/everolimus.

View Article and Find Full Text PDF

Background: Cardiac implantable electronic devices (CIEDs) are commonly associated with transvenous lead-related thrombi that can cause pulmonary embolism (PE).

Methods And Results: We retrospectively evaluated all patients with transvenous CIED leads implanted at Mayo Clinic Rochester between 1 January 2000, and 25 October 2010. Pulmonary embolism outcomes during follow-up were screened using diagnosis codes and confirmed with imaging study reports.

View Article and Find Full Text PDF

Background: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients.

Methods: We included 44 patients (mean age: 13.

View Article and Find Full Text PDF

Transcatheter ablation procedures have been traditionally performed under fluoroscopic guidance. However, x-ray exposure is afflicted by the risk of developing malignancies as well as other deterministic effects of radiation. For this reason, radiation doses in the interventional laboratory should be reduced "As Low As Reasonably Achievable", with respect to the safety of the patients and the medical staff.

View Article and Find Full Text PDF

Objective: To investigate a potential relationship between implantable cardioverter defibrillator (ICD) therapies and daily geomagnetic activity (GMA) recorded in a large database.

Patients And Methods: The ALTITUDE database, derived from the Boston Scientific LATITUDE remote monitoring system, was retrospectively analyzed for the frequency of ICD therapies. Daily GMA was expressed as the planetary K-index and the integrated A-index and was graded as levels I (quiet), II (unsettled), III (active), and IV (storm).

View Article and Find Full Text PDF

Background: Prior cardiac surgery, especially the presence of coronary artery bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, therefore, mapping and ablation. We evaluated the feasibility and safety of EpiAcc in patients with a prior cardiac operation.

Methods And Results: We retrospectively analyzed all patients who underwent EpiAcc for ablation for ventricular tachycardia or symptomatic premature ventricular complexes between 2004 and 2013 at Mayo Clinic, Rochester, MN.

View Article and Find Full Text PDF

Background: This case-series highlights strategies used for successful epicardial access in challenging cases. Percutaneous epicardial access has become a valuable tool for mapping and ablating arrhythmias. However, this technique can be especially difficult in certain circumstances and is frequently avoided.

View Article and Find Full Text PDF

Pulmonary vein isolation is an established therapeutic procedure for symptomatic atrial fibrillation (AF). This approach involves ablation of atrial tissue just outside the pulmonary veins. However, patient outcomes are limited because of a high rate of arrhythmia recurrence.

View Article and Find Full Text PDF

Background: Simultaneous multipolar ablation catheters have been proposed to simplify pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (AF). Recently, a new multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™, Biosense Webster Inc., Diamond Bar, CA, USA) combining both 3-dimensional electroanatomic mapping and multipolar open-irrigated ablation capability has been developed.

View Article and Find Full Text PDF

Background: Neurocardiogenic syncope (NCS) is a common and sometimes debilitating disorder, with no consistently effective treatment. NCS is due to a combination of bradycardia and vasodilation leading to syncope. Although pacemaker devices have been tried in treating the bradycardic aspect of NCS, no device-based therapy exists to treat the coexistent vasodilation that occurs.

View Article and Find Full Text PDF

Aims: Atrial tachycardias are common after repair of atrial septal defect (ASD). Although ablation has shown promising results in the short and mid-term follow-up, little data regarding the very long-term success exist. Our aim was to assess very long-term follow-up in patients who have undergone electroanatomic-guided radiofrequency (RF) ablation of late-onset atrial arrhythmias after ASD surgery.

View Article and Find Full Text PDF

Introduction: Outflow tract ventricular arrhythmia (OTVA) can be complicated to target for ablation when originating from either the periaortic or pulmonary valve (PV) region. Both sites may present with a small R wave in lead V1. However, the utility of lead I in distinguishing these arrhythmia locations is unknown.

View Article and Find Full Text PDF

Introduction: An increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation-related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.

Methods: We searched the Mayo Clinic MV surgical database over a 19-year period (1993-2012) and the electrophysiologic procedures database over a 23-year period (1990-2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.