Publications by authors named "E Vano"

The use of radiological procedures has enormously advanced cardiology. People with heart disease are exposed to ionizing radiation. Exposure to ionizing radiation increases lifetime cancer risk with a dose-proportional hazard according to the linear no-threshold model adopted for radioprotection purposes.

View Article and Find Full Text PDF

Dose management systems (DMS) are an essential tool for quality assurance and optimising patient radiation exposure. For radiologists and medical physicists, they are important for managing many radiation protection tasks. In addition, they help fulfil the requirements of Directive 2013/59/EURATOM regarding the electronic transmission of dosimetric data and the detection of unintended patient exposures.

View Article and Find Full Text PDF

Dual-energy CT (DECT) imaging has broadened the potential of CT imaging by offering multiple postprocessing datasets with a single acquisition at more than one energy level. DECT shows profound capabilities to improve diagnosis based on its superior material differentiation and its quantitative value. However, the potential of dual-energy imaging remains relatively untapped, possibly due to its intricate workflow and the intrinsic technical limitations of DECT.

View Article and Find Full Text PDF

The purpose of this article is to describe the activities developed within the framework "Regional Workshop on Optimization of Protection in Pediatric Interventional Radiology in Latin American and Caribbean countries," developed between October 16th and 19th of the year 2023 in the city of San José, Costa Rica. The workshop was carried out as part of a joint work between the Pan American Health Organization (PAHO) and the World Health Organization (WHO), in cooperation with the International Atomic Energy Agency (IAEA). The main objective of the regional workshop was to gather the experiences and future work planning among participants in the Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean (OPRIPALC) program.

View Article and Find Full Text PDF

Interventional radiology is a clinical practice with important benefits for patients, but which involves high radiation doses. The optimisation of radiation protection (RP) for paediatric interventional cardiology is a priority for both patients and staff. The use of diagnostic reference levels (DRLs) has been proposed by the International Commission on Radiological Protection to improve RP in imaging procedures.

View Article and Find Full Text PDF