Publications by authors named "E Ryba"

A new configuration for a thermoluminescent dosimetric card has been developed through collaboration between the Institute of Nuclear Physics in Kraków and several commercial dosimetric companies. The card is based on high-sensitivity LiF:Mg,Cu,P circular pellets (MCP-N) welded inside synthetic foils. The basic configuration consists of two pellets of 3.

View Article and Find Full Text PDF

One lesson learned from the Chernobyl accident was that the spatial distribution of far-field contamination was strongly non-uniform due to local variation of atmospheric conditions, such as wind direction, rain etc. An environmental monitoring system using highly sensitive thermoluminescent LiF:Mg,Cu,P (MCP-N) detectors has been completed and field-tested. The system consists of 3000 MCP-N detectors in 1000 TLD cards (three TLDs per card), two Mikrolab automatic TL readers, heating ovens, and specially developed software which includes a database for rapid evaluation of results.

View Article and Find Full Text PDF

starting by 6 h following diazepam injection and returning to approximately control values by 24 h. In situ hybridization showed elevated FGF-2 mRNA labeling in the hippocampal formation, mostly in the pyramidal layer of the CA1 and CA2 subfields and in the dentate gyrus hilar region. These results indicate that diazepam treatment up-regulates FGF-2 expression in select regions of the brain and suggest that GABA may promote neuroplasticity in concert with FGF-2.

View Article and Find Full Text PDF

A new cryosurgical device was developed in an attempt to overcome problems of current systems. It incorporates a mixed-fluid J-T stage, thereby reducing working pressure. This allows incorporation of an oil-free compressor to circulate the mixture and eliminates the need for coolant replenishment.

View Article and Find Full Text PDF

Background: Bioprostheses preserved with glutaraldehyde, both porcine and pericardial, have been available as second-generation prostheses for valve replacement surgery. The performance with regard to structural valve deterioration with the Carpentier-Edwards supra-annular (CE-SAV) porcine bioprosthesis and the Carpentier-Edwards Perimount (CE-P) pericardial bioprosthesis (Baxter Healthcare Corp, Edwards Division, Santa Ana, Calif) was evaluated to determine whether there was a difference in mitral valve replacement.

Methods: The CE-SAV bioprosthesis was implanted in 1266 overall mitral valve replacements (isolated mitral, 1066; mitral in multiple, 200) and the CE-P bioprosthesis in 429 overall mitral valve replacements (isolated mitral, 328; mitral in multiple, 101).

View Article and Find Full Text PDF