Publications by authors named "E Rapisarda"

Muonic atom spectroscopy-the measurement of the x rays emitted during the formation process of a muonic atom-has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom.

View Article and Find Full Text PDF

Statement Of Problem: Different technologies have been used to fabricate trial restorations. However, studies investigating the accuracy of trial restorations fabricated with different techniques in comparison with the initial 3-dimensional virtual design are lacking.

Purpose: The purpose of this clinical study was to evaluate completely digital workflows for managing the esthetic outcome through the production of trial restorations with 2 different technologies: stereolithography apparatus (SLA 3D) and computer-aided design and computer-aided manufacturing (CAD-CAM).

View Article and Find Full Text PDF

The β decay of ^{208}Hg into the one-proton hole, one neutron-particle _{81}^{208}Tl_{127} nucleus was investigated at CERN-ISOLDE. Shell-model calculations describe well the level scheme deduced, validating the proton-neutron interactions used, with implications for the whole of the N>126, Z<82 quadrant of neutron-rich nuclei. While both negative and positive parity states with spin 0 and 1 are expected within the Q_{β} window, only three negative parity states are populated directly in the β decay.

View Article and Find Full Text PDF

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s.

View Article and Find Full Text PDF

Objectives: To compare the percentage of voids in matched-taper single-cone fillings with GuttaFlow Bioseal or BioRoot RCS root canal sealers, using micro-computed tomography.

Materials And Methods: Forty-eight single-rooted mandibular premolars were prepared using rotary files and randomly allocated into 2 groups (n = 24), wherein the canals were filled with a matched-taper single gutta-percha cone and one of the two sealers: Group 1, GuttaFlow Bioseal and Group 2, BioRoot RCS. The specimens were scanned with micro-CT before and after root canal filling.

View Article and Find Full Text PDF