Publications by authors named "Dustin Gress"

Background: While many clinical computed tomography (CT) protocols use helical scanning, the traditional method for measuring the volume CT Dose Index (CTDI) requires modifying the helical protocol to perform a single axial rotation. This modification can present challenges and mismatched settings across various scanner models.

Purpose: This study investigates the generalizability of a helical methodology for estimating CTDI across a diverse range of participants, CT scanner models, and protocol parameters.

View Article and Find Full Text PDF

Objective: This study sought to determine consensus opinions from subspecialty radiologists and imaging physicists on the relative importance of image quality features in CT.

Methods: A prospective survey of subspecialty radiologists and medical physicists was conducted to collect consensus opinions on the relative importance of 10 image quality features: axial sharpness, blooming, contrast, longitudinal sharpness, low-contrast axial sharpness, metal artifact, motion, noise magnitude, noise texture, and streaking. The survey was first sent to subspecialty radiologists in volunteer leadership roles in the ACR and RSNA, thereafter relying on snowball sampling.

View Article and Find Full Text PDF

The historic and ongoing evolution of the practice, technology, terminology, and implementation of programs related to quality in the medical radiological professions has given rise to the interchangeable use of the terms Quality Management (QM), Quality Assurance (QA), and Quality Control (QC) in the vernacular. This White Paper aims to provide clarification of QM, QA, and QC in medical physics context and guidance on how to use these terms appropriately in American College of Radiology (ACR) Practice Parameters and Technical Standards, generalizable to other guidance initiatives. The clarification of these nuanced terms in the radiology, radiation oncology, and nuclear medicine environments will not only boost the comprehensibility and usability of the Medical Physics Technical Standards and Practice Parameters, but also provide clarity and a foundation for ACR's clinical, physician-led Practice Parameters, which also use these important terms for monitoring equipment performance for safety and quality.

View Article and Find Full Text PDF

Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed.

View Article and Find Full Text PDF

Objective: To examine dose-response associations between use of specific social media sites and the use of electronic cigarettes (e-cigarettes) and traditional cigarettes.

Methods: This was a cross-sectional study of 298 first-year college students enrolled in the fall 2019 semester at a large state university. Heckman selection and Probit model were used to estimate associations between use of specific social media sites and e-cigarette/traditional cigarette use.

View Article and Find Full Text PDF

Background: Although Pinterest has become a popular platform for distributing influential information that shapes users' behaviors, the role of recipes pinned on Pinterest in these behaviors is not well understood.

Objective: This study aims to explore the patterns of food ingredients and the nutritional content of recipes posted on Pinterest and to examine the factors associated with recipes that engage more users.

Methods: Data were collected from Pinterest between June 28 and July 12, 2020 (207 recipes and 2818 comments).

View Article and Find Full Text PDF

Purpose: The deformable nature of the liver can make focal treatment challenging and is not adequately addressed with simple rigid registration techniques. More advanced registration techniques can take deformations into account (eg, biomechanical modeling) but require segmentations of the whole liver for each scan, which is a time-intensive process. We hypothesize that fully convolutional networks can be used to rapidly and accurately autosegment the liver, removing the temporal bottleneck for biomechanical modeling.

View Article and Find Full Text PDF

The purpose of this study was to investigate whether systematic bias in attenuation measurements occurs among CT scanners made by four major manufacturers and the relevance of this bias regarding opportunistic screening for osteoporosis. Data on attenuation measurement accuracy were acquired using the American College of Radiology (ACR) accreditation phantom and were evaluated in a blinded fashion for four CT manufacturers (8500 accreditation submissions for manufacturer A; 18,575 for manufacturer B; 8278 for manufacturer C; and 32,039 for manufacturer D). The attenuation value for water, acrylic (surrogate for trabecular bone), and Teflon (surrogate for cortical bone; Chemours) materials for an adult abdominal CT technique (120 kV, 240 mA, standard reconstruction algorithm) was used in the analysis.

View Article and Find Full Text PDF

Purpose: Grid artifacts occur in digital mammography when synchronization between the grid assembly and generator is not achieved, including when malfunctions occur in the grid assembly or generator subsystems. Such artifacts are not explicitly monitored or evaluated by existing mammography quality control programs. In this study, we developed an automated method for quantifying the presence of grid artifacts in two-dimensional (2D) digital mammography images and assessed its utility as a supplement to existing quality control programs.

View Article and Find Full Text PDF

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States.

View Article and Find Full Text PDF

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States.

View Article and Find Full Text PDF

The American Association of Physicists in Medicine (AAPM) and the Society of Nuclear Medicine and Molecular Imaging (SNMMI) recognized the need for a review of the current state of nuclear  medicine physics training and the need to explore pathways for improving nuclear medicine physics training opportunities. For these reasons, the two organizations formed a joint AAPM/SNMMI Ad Hoc Task Force on Nuclear Medicine Physics  Training. The mission of this task force was to assemble a representative group of stakeholders to:• Estimate the demand for board-certified nuclear medicine physicists in the next 5-10 years,• Identify the critical issues related to supplying an adequate number of physicists who have received the appropriate level of training in nuclear medicine physics, and• Identify approaches that may be considered to facilitate the training of nuclear medicine physicists.

View Article and Find Full Text PDF

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States.

View Article and Find Full Text PDF

Purpose: The aims of this study were to measure the effectiveness of a multidisciplinary CT dose optimization committee and estimate its costs and to describe a radiation stewardship quality improvement initiative in one CT department at a medium-sized community hospital system that used a participatory design committee methodology.

Methods: A CT dose optimization committee was conceived, funded, and formed, consisting of the following stakeholders: radiologists, technologists, consultant medical physicists, and an administrator. Volume CT dose index (CTDIvol) and repeat rate were monitored for 1 month, for one scan type, during which iterative protocol adjustments were made through committee interaction.

View Article and Find Full Text PDF