Background: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components.
Methods: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components.
Early diagnosis and treatment of surgical wound infection can be challenging. This is especially relevant in the management of periprosthetic joint infection: early detection is key to success and reducing morbidity, mortality and resource use. 'Smart' dressings have been developed to detect parameters suggestive of infection.
View Article and Find Full Text PDFBackground: The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center.
View Article and Find Full Text PDFPurpose: Obesity is prevalent, with nearly one-third of the world's population being classified as obese. In patients with high body mass index (BMI)/body mass undergoing total knee arthroplasty (TKA), there is an increase in strain placed on the implant fixation interfaces. As such, component fixation is a potential concern when performing TKA in the obese patient.
View Article and Find Full Text PDFIntroduction: Biological disease-modifying antirheumatic drugs (bDMARDs) have revolutionised the treatment of inflammatory arthritis (IA). However, many people with IA still require planned orthopaedic surgery to reduce pain and improve function. Currently, bDMARDs are withheld during the perioperative period due to potential infection risk.
View Article and Find Full Text PDFBackground: Stiffness is a common complication following total knee arthroplasty. Manipulation under anesthesia (MUA) is an intervention that can potentially improve range of motion (ROM). Continuous passive motion (CPM) therapy has been utilized to enhance post-MUA ROM, but its effectiveness remains debated.
View Article and Find Full Text PDFBackground: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years).
Methods: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019).
Background: A recent National Joint Registry report suggests a higher local complication risk for dual-mobility (DM) total hip arthroplasty (THA) compared to conventional articulation THA. This report may be subject to data heterogeneity with multiple confounders. Controlling for these factors by matching demographic characteristics may give different results.
View Article and Find Full Text PDFPatients undergoing planned or unplanned orthopaedic procedures involving their upper or lower extremity can prevent them from safe and timely return to driving, where they commonly ask, 'Doctor, when can I drive?' Driving recommendations after such procedures are varied. The current evidence available is based on a heterogenous data set with varying degrees of sample size and markedly differing study designs. This instructional review article provides a scoping overview of studies looking at return to driving after upper or lower extremity surgery in both trauma and elective settings and, where possible, to provide clinical recommendations for return to driving.
View Article and Find Full Text PDFStrategies Trauma Limb Reconstr
January 2023
Introduction: Knee joint distraction (KJD) is a potential technique for cartilage regeneration in young patients with osteoarthritis of the knee. Static distraction has been utilised typically; however, a significant proportion of patients complain of knee stiffness post-distractor removal. The use of a hinged distractor may reduce the duration and severity of post-treatment knee stiffness by maintaining the range of motion during distraction.
View Article and Find Full Text PDFBackground Preoperative templating aids the surgeon in estimating implant size and placement. Calibration markers are used to set the correct magnification of digital images before templating. Improper marker placement or complete absence can lead to inaccuracy or an inability to calibrate images altogether.
View Article and Find Full Text PDFBackground: This article focuses on clinical implementation of smart knee implants for total knee replacement and the future development of smart implant technology. With the number of total knee replacements undertaken growing worldwide, smart implants incorporating embedded sensor technology offer opportunity to improve post-operative recovery, reducing implant failure rates, and increasing overall patient satisfaction.
Methods: A literature review on smart implants, historical prototypes, current clinically available smart implants, and the future potential for conventional implant instrumentation with embedded sensors and electronics was undertaken.
Background: Total knee arthroplasty requires effective rehabilitation to achieve optimal results, but institutions often rely on unsupervised home exercises due to cost constraints. Wearable sensors have become increasingly popular as a potential method of monitoring patients remotely to ensure efficacy and compliance. This review assesses the current evidence for their use in remotely monitored rehabilitation following knee arthroplasty.
View Article and Find Full Text PDFUse of articular antibiotic-eluting cement spacers during two-stage revision arthroplasty for prosthetic joint infection (PJI) is a long-established and proven adjunctive technique during first-stage surgery. Articular spacers come in many forms, either static or dynamic. The authors present an instructional review of current evidence regarding their use.
View Article and Find Full Text PDFBackground: Biologic disease-modifying anti-rheumatic drugs (bDMARDs) are effective in treating inflammatory diseases and have been increasingly utilized over the past decade. Patients who receive bDMARDs have been shown to be at an increased risk for surgical site infection following surgical procedures. The severe consequences of infection following orthopaedic surgery have led to the practice of withholding bDMARDs perioperatively; however, there has been no definitive evidence showing a clear benefit of withholding the use of bDMARDs, and in doing so, patients may be at an increased risk for higher disease activity.
View Article and Find Full Text PDFPurpose: To consolidate the evidence from the available literature and undertake a meta-analysis to provide a reference for physicians to make evidence-based recommendations to their patients regarding the return to driving after hip or knee arthroscopic procedures.
Methods: A systematic review was conducted using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. The OVID, Embase, and Cochrane databases were searched through June 2020 for articles containing keywords and/or MeSH (Medical Subject Headings) terms "hip arthroscopy" and "knee arthroscopy" in conjunction with "total brake response time" or "reaction time" in the context of automobile driving.
Background And Objective: Surgical drains are widely utilized in hepatopancreaticobiliary surgery to prevent intra-abdominal collections and identify postoperative complications. Surgical drain monitoring ranges from simple-output measurements to specific analysis for constituents such as amylase. This systematic review aimed to determine whether surgical drain monitoring can detect postoperative complications and impact on patient outcomes.
View Article and Find Full Text PDFBackground: There is limited evidence available on return to driving for patients undergoing knee arthroplasty (KA). Primarily, surgeons have used brake reaction time as a surrogate measure of safe return to driving. The purpose of this study was to review existing literature and provide guidance on the recovery of braking performance following knee arthroplasty.
View Article and Find Full Text PDFBackground/objective: Advice given to patients on driving resumption after total hip arthroplasty (THA) is inconsistent. Due to a lack of clear guidelines, surgeons' recommendations range between 4-8 weeks after surgery to resume driving. Delays in driving return can have detrimental social and economic impact.
View Article and Find Full Text PDFPurpose: The purpose of this study was to perform a systematic review and meta-analysis to compare clinical and patient-reported outcome measures of medially stabilised (MS) TKA when compared to other TKA designs.
Methods: The Preferred Reporting Items for Systematic Review and Meta-Analyses algorithm was used. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and EMCARE databases were searched to June 2020.
Purpose: Accurately predicting implant size for hemiarthroplasties offers an important contribution to theatre efficiency and patients' intraoperative care. However, pre-operative sizing using templating of implants in hip fracture patients requiring a hemiarthroplasty is often difficult due to non-standard radiographs, absence of a calibration marker, poor marker placement, variable patient position, and in many institutions a lack of templating facilities. In patients who have previously undergone a hemiarthroplasty on the contralateral side, surgeons can use the contralateral implant size for pre-operative planning purposes.
View Article and Find Full Text PDFIt is well recognised that acetabular cup orientation influences patient function and implant survival post-THR. Reliable intra-operative determination of cup orientation remains a challenge. We describe the design and testing of a novel mechanical inclinometer to measure intra-operative acetabular cup inclination.
View Article and Find Full Text PDF