This study assesses radiation doses in cone beam computed tomography (CBCT) procedures in Sri Lanka, with the goal of establishing initial diagnostic reference levels (DRLs). Data from 1162 retrospective scans across four institutions were analyzed, and the medians of the pooled dose distribution for seven clinical indication categories were presented as the DRL values. The proposed DRLs based on clinical indications are 1013 mGy·cm2 for pathological conditions including cysts, tumors, and lesions, 1307 mGy·cm2 for implant planning, 1266 mGy·cm2 for presurgery assessment, and 1585 mGy·cm2 for evaluation of sinus and nasal pathology, temporomandibular disorder, and facial trauma.
View Article and Find Full Text PDFJ Radiol Prot
July 2023
This study represents the first national survey conducted in Sri Lanka to establish national diagnostic reference levels (NDRLs) for screening and diagnostic acquisitions in digital mammography (2D-DM) and digital breast tomosynthesis (DBT). Additionally, the study investigated the relationship between average glandular dose (AGD) and compressed breast thickness (CBT) and introduced a novel concept called dose range bands (DRBs) as a tool for optimizing radiation dose in mammography. DICOM metadata was used to extract dose data and exposure parameters from women undergoing either screening (350) or diagnostic (750) DM.
View Article and Find Full Text PDFIn head and neck computed tomography (CT) imaging, the optimisation of radiation dose is crucial due to the presence of radio-sensitive organs. This study aimed to evaluate the radiation dose in multi-slice CT for head and neck examinations. Volume CT dose index, dose length product and effective dose (E) were assessed for 10 head and neck CT scans performed on 292 adult patients (mean age 49.
View Article and Find Full Text PDFThe present survey evaluated the level of awareness of radiological protection concepts and imaging parameters among Sri Lankan radiographers for the first time. The data were collected using an electronic questionnaire of 22 questions on demographic data, awareness of radiation protection concepts and imaging parameters. Only 84 out of 122 (68.
View Article and Find Full Text PDFThis study aimed to establish dose reference level (NDRLSSDE) based on size-specific dose estimate (SSDE) derived using effective diameter (Deff) for adult chest and abdomen computed tomography (CT) procedures and to explore the feasibility of drivingDeffusing the product of tube current and time (mAs). In this retrospective study, dose data, scan parameters and patient body dimensions at the mid-slice level from 14 CT units (out of 63 total) were extracted. Additionally, the mAs values of the axial slice at the same-location where the diameter measurements were made (mAs) were recorded.
View Article and Find Full Text PDFIntroduction: The paediatric radiation dose has never been studied in Sri Lanka, nor has a national diagnostic reference level (NDRL) established. Therefore, the primary aim of this study was to propose diagnostic reference levels (DRL) and achievable dose (AD) values for paediatric CT examinations based on size.
Methods: A total of 658 paediatric (0-15 years) non-contrast-enhanced (NC) studies of head, chest and abdomen regions performed during six months in two dedicated paediatric hospitals (out of the three such institutions in the country) were included.
The main purpose of this study was to establish for the first time national diagnostic reference levels (NDRLs) for common computed tomography (CT) procedures in Sri Lanka. Patient morphometric data, exposure parameters and dose data such as volume CT dose index (CTDIvol) and dose-length product (DLP) were collected from 5666 patients who underwent 22 types of procedure. The extreme dose values were filtered before analysis to ensure that the data come from standard size patients.
View Article and Find Full Text PDFThis study aimed to evaluate the collimation practices and quantify the overexposure due to extensive X-ray field area. The study was carried out in four digital X-ray units (including one paediatric X-ray unit). A total of 749 X-ray projections (555 adult and 194 paediatric) were evaluated.
View Article and Find Full Text PDF