Publications by authors named "Duewer D"

Recombinant adeno-associated virus (AAV) is one of the main viral vector-based gene therapy platforms. AAV is a virus consisting of a ≈25 nm diameter capsid with a ≈4.7 kb cargo capacity.

View Article and Find Full Text PDF

Biopharmaceuticals such as monoclonal antibodies are required to be rigorously characterized using a wide range of analytical methods. Various material properties must be characterized and well controlled to assure that clinically relevant features and critical quality attributes are maintained. A thorough understanding of analytical method performance metrics, particularly emerging methods designed to address measurement gaps, is required to assure methods are appropriate for their intended use in assuring drug safety, stability, and functional activity.

View Article and Find Full Text PDF

The measurement of polydisperse protein aggregates and particles in biotherapeutics remains a challenge, especially for particles with diameters of ≈ 1 µm and below (sub-micrometer). This paper describes an interlaboratory comparison with the goal of assessing the measurement variability for the characterization of a sub-micrometer polydisperse particle dispersion composed of five sub-populations of poly(methyl methacrylate) (PMMA) and silica beads. The study included 20 participating laboratories from industry, academia, and government, and a variety of state-of-the-art particle-counting instruments.

View Article and Find Full Text PDF
Article Synopsis
  • The Vitamin D External Quality Assessment Scheme (DEQAS) sends human serum samples to over 1000 global participants to measure total serum 25-hydroxyvitamin D levels four times a year.
  • A study was conducted to determine if shipping these samples at ambient temperature affects the reliability of various 25(OH)D assays compared to shipping them frozen.
  • Results showed significant differences for four specific assays when samples were shipped ambiently, but all 14 LC-MS/MS assays showed no significant differences, indicating they remained stable during shipping at room temperature.
View Article and Find Full Text PDF

Vitamin C is a necessary micronutrient that is involved in many biological processes. In preserved human plasma and serum, vitamin C is most meaningfully analyzed as total ascorbic acid (TAA). From 1993 through 2015, the National Institute of Standards and Technology (NIST) coordinated 40 interlaboratory studies (ILS) devoted to improving the between-participant comparability of TAA measurements.

View Article and Find Full Text PDF
Article Synopsis
  • dPCR is highlighted as an effective method for measuring DNA concentration by amplifying target sequences in separate reaction partitions and determining their signal levels.
  • Converting double-stranded DNA (dsDNA) to single-stranded DNA (ssDNA) before this process may lead to an overestimation of concentrations, prompting the need to accurately assess ssDNA levels in samples.
  • Various techniques were evaluated for estimating ssDNA proportions, with the endonuclease-based approach proving the most accurate, though differences in ssDNA content were observed depending on the assay used, possibly due to variations in GC content.
View Article and Find Full Text PDF

The National Institute of Standards and Technology (NIST), formerly the National Bureau of Standards, was established by the US Congress in 1901 and charged with establishing a measurement foundation to facilitate US and international commerce. This broad language provides NIST with the ability to establish and implement its programs in response to changes in national needs and priorities. This review traces some of the changes in NIST's reference material programs over time and presents the NIST Material Measurement Laboratory's current approach to promoting accuracy and metrological traceability of chemical measurements and validation of chemical measurement processes.

View Article and Find Full Text PDF
Article Synopsis
  • * Seventy-six laboratories from various sectors around the world participated, submitting 103 reports using different analytical methods to examine glycan distributions.
  • * The study revealed significant diversity in results, with up to 48 glycan compositions identified by individual labs, highlighting the need for standardization in glycosylation analysis methods.
View Article and Find Full Text PDF

Metrological traceability for organic chemical measurements is a documented unbroken chain of calibrations with stated uncertainties that ideally link the measurement result for a sample to a primary calibrator in appropriate SI units (e.g., mass fraction).

View Article and Find Full Text PDF

The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference.

View Article and Find Full Text PDF

Droplet digital PCR (ddPCR) is being advocated as a reference method to measure rare genomic targets. It has consistently been proven to be more sensitive and direct at discerning copy numbers of DNA than other quantitative methods. However, one of the largest obstacles to measuring microRNA (miRNA) using ddPCR is that reverse transcription efficiency depends upon the target, meaning small RNA nucleotide composition directly effects primer specificity in a manner that prevents traditional quantitation optimization strategies.

View Article and Find Full Text PDF

Digital polymerase chain reaction (dPCR) end point platforms directly estimate the number of DNA target copies per reaction partition, λ, where the partitions are fixed-location chambers (cdPCR) or aqueous droplets floating in oil (ddPCR). For use in the certification of target concentration in primary calibrant certified reference materials (CRMs), both λ and the partition volume, V, must be metrologically traceable to some accessible reference system, ideally, the International System of Units (SI). The fixed spatial distribution of cdPCR chambers enables real-time monitoring of PCR amplification.

View Article and Find Full Text PDF

Polymerase chain reaction (PCR) multiplexed assays perform best when the input quantity of template DNA is controlled to within about a factor of √2. To help ensure that PCR assays yield consistent results over time and place, results from methods used to determine DNA quantity need to be metrologically traceable to a common reference. Many DNA quantitation systems can be accurately calibrated with solutions of DNA in aqueous buffer.

View Article and Find Full Text PDF

A number of scoring systems for proficiency testing and interlaboratory comparison are in use by the metrology community. The choice of scoring system for a given study is often based on the study coordinator's experience and anecdotal knowledge, perhaps attributable to a historic lack of detailed and formal explanation about the foundation of these systems. This has influenced the development of new scoring systems, some of them departing from the well-established hypothesis testing theory.

View Article and Find Full Text PDF

Polymerase chain reaction (PCR) end-point limiting dilution techniques, collectively termed "digital PCR (dPCR)", have been proposed as providing a potentially primary method for DNA quantification. We are evaluating several commercially available dPCR systems for use in certifying mass concentration in human genomic DNA reference materials. To better understand observed anomalies among results from chamber- and droplet-dPCR (cdPCR and ddPCR) systems, we have developed a graphical tool for evaluating and documenting the performance of PCR assays in real-time cdPCR systems: the ogive plot, the cumulative distribution of crossing threshold values.

View Article and Find Full Text PDF

The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems.

View Article and Find Full Text PDF

Studies of climate change increasingly recognize the diverse influences of hydrocarbons in the atmosphere, including roles in particulates and ozone formation. Measurements of key nonmethane hydrocarbons (NMHCs) suggest atmospheric mole fractions ranging from low picomoles per mol (ppt) to nanomoles per mol (ppb), depending on location and compound. To accurately establish mole fraction trends and to relate measurement records from many laboratories and researchers, it is essential to have accurate, stable, calibration standards.

View Article and Find Full Text PDF

The National Institute of Standards and Technology administers quality assurance programs devoted to improving measurements of nutrients and related metabolites in foods, dietary supplements, and serum and plasma samples. These programs have been developed in collaboration with the National Institutes of Health to assist measurement communities in their efforts to achieve accurate results that are comparable among different laboratories and over time. Targeted analytes include micronutrients, botanical markers, nutritional elements, contaminants, fatty acids, and vitamin D metabolites.

View Article and Find Full Text PDF

The Consultative committee for amount of substance-metrology in chemistry (CCQM)-K80 Key Comparison directly assessed the equivalence of many of the world's higher-order value-assigned materials (HOVAMs) for creatinine in human serum. This 2009 international study compared the certified values and uncertainties of the materials using measurements made under repeatability conditions. The study evaluated 17 materials submitted by 6 national metrology institutes (NMIs).

View Article and Find Full Text PDF

Several recent international comparison studies used a relatively novel experimental design to evaluate the measurement capabilities of participating organizations. These studies compared the values assigned by each participant to one or more qualitatively similar materials with measurements made on all of the materials by one laboratory under repeatability conditions. A statistical model was then established relating the values to the repeatability measurements; the extent of agreement between the assigned value(s) and the consensus model reflected the participants' measurement capabilities.

View Article and Find Full Text PDF

A suite of three green tea-containing Standard Reference Materials (SRMs) has been issued by the National Institute of Standards and Technology (NIST): SRM 3254 Camellia sinensis (Green Tea) Leaves, SRM 3255 Camellia sinensis (Green Tea) Extract, and SRM 3256 Green Tea-Containing Solid Oral Dosage Form. The materials are characterized for catechins, xanthine alkaloids, theanine, and toxic elements. As many as five methods were used in assigning certified and reference values to the constituents, with measurements carried out at NIST and at collaborating laboratories.

View Article and Find Full Text PDF

Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program.

View Article and Find Full Text PDF

The National Institute of Standards and Technology (NIST) has established a Dietary Supplement Laboratory Quality Assurance Program (DSQAP) in collaboration with the National Institutes of Health Office of Dietary Supplements. Program participants measure concentrations of active and/or marker compounds as well as nutritional and toxic elements in food and dietary supplements distributed by NIST. Data are compiled at NIST, where they are analyzed for accuracy relative to reference values and concordance among the participants.

View Article and Find Full Text PDF