Deep learning is a powerful tool that became practical in 2008, harnessing the power of Graphic Processing Unites, and has developed rapidly in image, video, and natural language processing. There are ongoing developments in the application of deep learning to medical data for a variety of tasks across multiple imaging modalities. The reliability and repeatability of deep learning techniques are of utmost importance if deep learning can be considered a tool for assisting experts, including physicians, radiologists, and sonographers.

View Article and Find Full Text PDF

Medical segmentation is an important but challenging task with applications in standardized report generation, remote medicine and reducing medical exam costs by assisting experts. In this paper, we exploit time sequence information using a novel spatio-temporal recurrent deep learning network to automatically segment the thyroid gland in ultrasound cineclips. We train a DeepLabv3+ based convolutional LSTM model in four stages to perform semantic segmentation by exploiting spatial context from ultrasound cineclips.

View Article and Find Full Text PDF

Sonographic features associated with margins, shape, size, and volume of thyroid nodules are used to assess their risk of malignancy. Automatically segmenting nodules from normal thyroid gland would enable an automated estimation of these features. A novel multi-output convolutional neural network algorithm with dilated convolutional layers is presented to segment thyroid nodules, cystic components inside the nodules, and normal thyroid gland from clinical ultrasound B-mode scans.

View Article and Find Full Text PDF

We applied sub-Hertz analysis of viscoelasticity (SAVE) to differentiate breast masses in pre-biopsy patients. Tissue response during external ramp-and-hold stress was ultrasonically detected. Displacements were used to acquire tissue viscoelastic parameters.

View Article and Find Full Text PDF

Two-dimensional (2D) ultrasound shear wave elastography (SWE) has been widely used for soft tissue properties assessment. Given that shear waves propagate in three dimensions (3D), extending SWE from 2D to 3D is important for comprehensive and accurate stiffness measurement. However, implementation of 3D SWE on a conventional ultrasound scanner is challenging due to the low volume rate (tens of Hertz) associated with limited parallel receive capability of the scanner's hardware beamformer.

View Article and Find Full Text PDF

Objectives: To evaluate the predictive performance of comb-push ultrasound shear elastography for the differentiation of reactive and metastatic axillary lymph nodes.

Methods: From June 2014 through September 2018, 114 female volunteers (mean age 58.1±13.

View Article and Find Full Text PDF

Tumor angiogenesis plays an important role during breast tumor growth. However, conventional Doppler has limited sensitivity to detect small blood vessels, resulting in a large overlap of Doppler features between benign and malignant tumors. An ultrasensitive ultrasound microvessel imaging (UMI) technique was recently developed.

View Article and Find Full Text PDF
Article Synopsis
  • A new computer-aided tool using the Multi U-net algorithm was developed to automatically detect and segment breast masses in clinical ultrasound scans of 258 female patients deemed suspicious.
  • The tool achieved impressive results with a mean Dice coefficient of 0.82, a true positive fraction of 0.84, and a very low false positive fraction of 0.01, indicating its reliability.
  • This algorithm operates without requiring an initial seed and can segment images in real time (13-55 ms per image), making it competitive with traditional methods and significantly better than earlier versions of the U-net algorithm.
View Article and Find Full Text PDF

Rationale And Objectives: Low specificity of traditional ultrasound in differentiating benign from malignant thyroid nodules leads to a great number of unnecessary (ie, benign) fine-needle aspiration biopsies that causes a significant financial and physical burden to the patients. Ultrasound shear wave elastography is a technology capable of providing additional information related to the stiffness of tissues. In this study, quantitative stiffness values acquired by ultrasound shear wave elastography in two different imaging planes were evaluated for the prediction of malignancy in thyroid nodules.

View Article and Find Full Text PDF

Quantification of liver elasticity is a major application of shear wave elasticity imaging (SWEI) to non-invasive assessment of liver fibrosis stages. SWEI measurements can be highly affected by ultrasound image quality. Ultrasound harmonic imaging has exhibited a significant improvement in ultrasound image quality as well as for SWEI measurements.

View Article and Find Full Text PDF

Objectives: To investigate the correlation between 2-dimensional (2D) ultrasound shear wave elastography (SWE) and magnetic resonance elastography (MRE) in liver stiffness measurement and the diagnostic performance of 2D SWE for liver fibrosis when imaging from different intercostal spaces and using MRE as the reference standard.

Methods: Two-dimensional SWE was performed on 47 patients. One patient was excluded from the study.

View Article and Find Full Text PDF

Purpose Or Objective: To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE) for classification of breast masses.

Materials And Methods: CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF) beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy.

View Article and Find Full Text PDF

Objectives: Magnetic resonance elastography (MRE) has excellent performance in detecting liver fibrosis and is becoming an alternative to liver biopsy in clinical practice. Ultrasound techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force also have shown promising results for liver fibrosis staging. The objective of this study was to compare ultrasound-based shear wave measurement to MRE.

View Article and Find Full Text PDF

In clinical practice, an overwhelming majority of biopsied thyroid nodules are benign. Therefore, there is a need for a complementary and noninvasive imaging tool to provide clinically relevant diagnostic information about thyroid nodules to reduce the rate of unnecessary biopsies. The goal of this study was to evaluate the feasibility of utilizing comb-push ultrasound shear elastography (CUSE) to measure the mechanical properties (i.

View Article and Find Full Text PDF

Shear wave speed can be used to assess tissue elasticity, which is associated with tissue health. Ultrasound shear wave elastography techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force are becoming promising alternatives to biopsy in liver fibrosis staging. However, shear waves generated by such methods are typically very weak.

View Article and Find Full Text PDF

Objectives: Abnormal gastric accommodation to a meal results in dyspepsia. Current methods to measure gastric volume (GV) are invasive or involve ionizing radiation. The aims of this study were to compare fasting and postprandial (PP) GVs measured by (99m)Tc-single photon emission computed tomography (SPECT) and 3-dimensional ultrasound (3D-US) in adults, to assess the performance characteristics of 3D-US measurement of GV during fasting and postprandially, and to develop normative data of GVs in 24 healthy adolescents.

View Article and Find Full Text PDF

Purpose: To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions.

Materials And Methods: Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant study. US strain imaging was performed prospectively for 89 breast lesions in 88 patients.

View Article and Find Full Text PDF