Publications by authors named "Du Chixin"

Several factors influence axial length in children with myopia treated using overnight orthokeratology. To identify these factors, this retrospective study collected axial length and corneal aberration data on 78 eyes before and 1-year after orthokeratology. Patients were divided according to axial elongation (cut-off, 0.

View Article and Find Full Text PDF

Purpose: Myopia treatment using orthokeratology (ortho-k) slows myopia progression. However, it is not equally effective in all patients. We aimed to predict the treatment effect of ortho-k using a machine-learning-assisted (ML) prediction model.

View Article and Find Full Text PDF

Myopia is a leading cause of visual impairment in young people worldwide. It sometimes increases the risk of blindness and reduces life quality. Previous reports have revealed the treatment effects of defocus-incorporated multiple segments (DIMS) and topical atropine (ATP) on myopia control.

View Article and Find Full Text PDF

Myopia is one of the main causes of visual impairment worldwide. Preventing myopia and providing myopia-related interventions are of paramount importance. Based on a thorough review of the available literature, we conclude that red light irradiation can produce hyperopia, resulting in myopia prevention and control.

View Article and Find Full Text PDF

Objectives: This randomized, single-blind, clinical trial compared the effectiveness of multifocal soft contact lenses (MFSCLs), orthokeratology contact lenses (Ortho-kCLs), and single vision spectacles (SVSs) for myopia control.

Methods: Sixty-six eligible Chinese subjects, aged 7 to 15 years old with cycloplegic refraction measurements between -1.00 and -8.

View Article and Find Full Text PDF

Purpose: To evaluate the global scientific output of research on ocular chronic Graft versus host disease (cGVHD) and explore the current status and trends in this field over the past decade by bibliometric analysis.

Methods: The bibliometric search was performed in the Web of Science Core Collection (WoSCC) database. VOSviewer v.

View Article and Find Full Text PDF

Motion contrast optical coherence tomography angiography (OCTA) entails a precise identification of dynamic flow signals from the static background, but an intermediate region with voxels exhibiting a mixed distribution of dynamic and static scatterers is almost inevitable in practice, which degrades the vascular contrast and connectivity. In this work, the static-dynamic intermediate region was pre-defined according to the asymptotic relation between inverse signal-to-noise ratio (iSNR) and decorrelation, which was theoretically derived for signals with different flow rates based on a multi-variate time series (MVTS) model. Then the ambiguous voxels in the intermediate region were further differentiated using a shape mask with adaptive threshold.

View Article and Find Full Text PDF
Article Synopsis
  • Genetic factors, particularly mutations in the major intrinsic protein (MIP) gene, play a crucial role in the development of cataracts, which this study focuses on at both DNA and protein levels.
  • A systematic review of multiple databases revealed 29 mutations in the MIP gene linked to congenital cataract, predominantly causing changes in the MIP protein structure, yet a direct link between these genetic mutations and lens morphology was not established.
  • The findings suggest that specific single-base mutations and polymorphisms in the MIP gene may contribute significantly to the onset of both congenital and age-related cataracts, offering important insights for future clinical research and studies.
View Article and Find Full Text PDF

Background: To determine the repeatability of measurements of ocular surface vessel density in normal and diseased eyes using optical coherence tomography angiography (OCTA).

Methods: Ten normal eyes, 10 pinguecula eyes, and 10 pterygium eyes of 30 volunteers were subjected to OCTA (AngioVue Imaging System, Optovue, Inc.).

View Article and Find Full Text PDF

Amino acids in human tears play certain physiological roles and their determination is challenging due to complicated chemical properties. This study described a fast and sensitive method for the simultaneous determination of 15 amino acids (AAs) in tears by hydrophilic interaction liquid chromatography and quadrupole orbitrap mass spectrometry (HILIC-Q-Orbitrap-MS). Amino acids in tears were extracted by methanol, and then cleaned up with a solid phase extraction (SPE) cartridge.

View Article and Find Full Text PDF

Purpose: To investigate the density of conjunctival blood vessels in normal eyes and in eyes with pinguecula or pterygium.

Methods: In this cross-sectional study, the conjunctival blood vessel density of 15 normal eyes, 15 pinguecula eyes, and 15 pterygium eyes of 43 healthy adults was assessed using optical coherence tomography angiography with an anterior segment lens adapter. The nasal surface of each eye (3 × 3 mm) was scanned 3 times to a depth of 800 μm.

View Article and Find Full Text PDF

Purpose: To investigate the influence of phenylephrine and tropicamide on anterior segment biometry with ultralong scan depth optical coherence tomography (UL-OCT) during accommodation.

Methods: In this study, 20 left eyes of healthy volunteers with a mean ± standard deviation age of 31.05 ± 5.

View Article and Find Full Text PDF

Tear is an accessible fluid for exploring biomarkers of dry eye disease. This study describes a fast proteomic method by LC-Q-orbitrap-MS analysis with in-strip digestion and investigates the tear proteome of dry eye patients. Schirmer's strips were used for collection of tear fluid from patients.

View Article and Find Full Text PDF
Article Synopsis
  • The mouse model is a key tool for studying myopia, with current induction techniques categorized into three main types: glued devices, glued and sutured devices, and skull-mounted apparatuses.
  • Each technique has its own pros and cons regarding stability, safety, and complexity, indicating a need for refinement in myopia induction methods.
  • The pilot study introduces a new head-mounted spectacle frame apparatus that simplifies the surgical attachment process and demonstrates effective myopia induction, improved safety, and compatibility with form deprivation for future research.
View Article and Find Full Text PDF

NaCl based solutions were applied as osmotic stress agents to alter the hydration state of the mouse eye. Full-eye responses to these osmotic challenges were monitored in vivo using a custom-built optical coherence tomography (OCT) with an extended imaging range of 12.38 mm.

View Article and Find Full Text PDF

The purpose of this study was to investigate the clinical characteristic and visual outcome of siderosis bulbi with retained intraocular foreign body (IOFB) and to validate the predictive value of the Ocular Trauma Score (OTS) in siderosis bulbi. Certain numerical values rendered to the OTS variables at present were summated (Table 1) and converted into 5 OTS categories as performed in the OTS study. The prognostic value of OTS was first assessed in cases of siderosis bulbi resulting from a chemical reaction of retained IOFBs.

View Article and Find Full Text PDF

Posterior polymorphous corneal dystrophy (PPCD) is an extremely rare, bilateral, and inherited disorder, which affects the corneal endothelium and Descemet's membrane. Few PPCD cases in Chinese patients have been published so far. As far as we know, there are few studies which focused on the associations between PPCD and high myopia either.

View Article and Find Full Text PDF

Purpose: To compare the ocular trauma score (OTS) and the paediatric penetrating ocular trauma score (POTS) as prognostic model for visual outcome in paediatric traumatic cataract cases after penetrating eye injuries.

Methods: All children younger than 16 years with unilateral traumatic cataract following penetrating trauma between 2007 and 2012 were retrospectively reviewed. Univariate chi-square analysis was conducted to identify the variables associated with profound visual loss.

View Article and Find Full Text PDF

We report on a phase-based method for accurately measuring the ocular pulse in the anterior chamber in vivo. Using phase-sensitive optical coherence tomography with optimized scanning protocols and equations for compensating bulk motion and environmental vibrations, a high sensitivity of 0.9 μm/s minimal velocity is demonstrated at a wide detection band of 0 to 380 Hz.

View Article and Find Full Text PDF

Purpose: To measure by ultralong scan depth optical coherence tomography (UL-OCT) dimensional changes in the anterior segment of human eyes during accommodation.

Design: Evaluation of diagnostic test or technology.

Participants: Forty-one right eyes of healthy subjects with a mean age of 34 years (range, 22-41 years) and a mean refraction of -2.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the pattern of variations in tear osmolarity and tear meniscus volume in patients with dry eyes and in healthy control subjects over an 8-hr daytime period.

Methods: Ten normal subjects (5 men and 5 women with a mean age of 27±7 years) and 10 dry eye patients (4 men and 6 women with a mean age of 36±12 years) who had been diagnosed on the basis of having an ocular surface discomfort index >12 and a tear breakup time of <10 sec or Schirmer test score of <5 mm were included. The tear meniscus volumes of the participants were measured using ultrahigh resolution optical coherence tomography (OCT), and tear osmolarity was measured using the TearLab Osmolarity System.

View Article and Find Full Text PDF

Purpose: To measure vertical and horizontal thickness profiles of the central and peripheral corneal epithelium and determine if daytime changes occur.

Methods: Forty eyes of 20 normal subjects were imaged by ultrahigh resolution spectral domain optical coherence tomography to profile the corneal epithelial thickness from the edge of Bowman layer to the central cornea across the vertical and horizontal meridians. Measurements were made at 10:00 AM and again at 6 and 8 hours later.

View Article and Find Full Text PDF

Purpose: To investigate changes in anterior chamber depth (ACD) and the distance between the Visian implantable Collamer lens (ICL) and the crystalline lens during pharmacologic accommodation in high myopia.

Design: Prospective, comparative case series.

Participants: Thirty-three phakic eyes of 18 high myopic patients (range, -8.

View Article and Find Full Text PDF