Publications by authors named "Drobetz H"

Background: The operating theatre generates substantial waste, raising environmental concerns. This study quantified the waste generated during four common orthopaedic procedures and identified recyclable materials. It also assessed the associated carbon footprint to highlight opportunities for sustainable waste management.

View Article and Find Full Text PDF

Objectives: Distal femoral fractures are a significant injury sustained by low- and high-energy trauma. Common treatment practices are lateral locking plate or intramedullary nail fixation, with disadvantages including risk of non and malunion and limited post-operative weightbearing status. Combining both techniques as a nail-plate construct (NPC) theoretically achieves enhanced fixation to allow immediate weightbearing.

View Article and Find Full Text PDF

Background: It is unknown whether total wrist arthrodesis (TWA) should be performed with or without arthrodesis of the carpometacarpal joint (CMCJ). The aim of this study is to compare CMCJ-spanning TWA plates using 3D printed wrist arthrodesis model with and without arthrodesis of the CMCJ.

Methods: Total wrist arthrodesis plates mounted to 3D printed models were tested under a 4-N bending load at 4 Hz for 50 000 cycles, increased by 15% every 10 000 cycles until failure.

View Article and Find Full Text PDF

Importance: Distal radius fractures are common and are managed with or without surgery. Current evidence indicates surgical treatment is not superior to nonsurgical treatment at 12 months.

Objective: Does surgical treatment for displaced distal radius fractures in patients 60 years or older provide better patient-reported wrist pain and function outcomes than nonsurgical treatment at 24 months?

Design, Setting, And Participants: In this secondary analysis of a combined multicenter randomized clinical trial (RCT) and a parallel observational study, 300 patients were screened from 19 centers in Australia and New Zealand.

View Article and Find Full Text PDF

Background: The coronavirus (COVID-19) pandemic has affected the utilisation of emergency department (ED) services worldwide. The aim of this study was to assess the impact of COVID-19-related public health measures on orthopaedic presentations to a regional Australian hospital.

Methods: A case-control study was performed at a regional trauma hospital in New South Wales (NSW), Australia.

View Article and Find Full Text PDF

Importance: The burden of injury and costs of wrist fractures are substantial. Surgical treatment became popular without strong supporting evidence.

Objective: To assess whether current surgical treatment for displaced distal radius fractures provided better patient-reported wrist pain and function than nonsurgical treatment in patients 60 years and older.

View Article and Find Full Text PDF

The aim of our study was to investigate the cumulative effective dose of radiation resulting from medical imaging in orthopaedic patients with isolated extremity trauma. Deidentified radiology records of consecutive patients without age restriction with isolated extremity trauma requiring operative treatment at a regional hospital were reviewed retrospectively over a 1-year period, and the effective dose per patient for each study type of plain film X-ray, computed tomography, and operative fluoroscopy was used to calculate cumulative effective dose. Values were summarised as mean, ± standard deviation, maximum, and proportion with overdose (>20 mSv).

View Article and Find Full Text PDF

Background: The coronavirus disease outbreak in December 2019 rapidly spread around the world with profound effects on healthcare systems. In March 2020, all elective surgery and elective outpatient clinics were cancelled in our institution, a regional hospital in Northern New South Wales, Australia. With regard to orthopaedic fracture clinics, a telehealth system was implemented on an emergency basis for patient and staff safety to prevent disease transmission.

View Article and Find Full Text PDF

Background: We are performing a combined randomised and observational study comparing internal fixation to non-surgical management for common wrist fractures in older patients. This paper describes the statistical analysis plan.

Methods/design: A Combined Randomised and Observational Study of Surgery for Fractures In the distal Radius in the Elderly (CROSSFIRE) is a randomised controlled trial comparing two types of usual care for treating wrist fractures in older patients, surgical fixation using volar locking plates and non-surgical treatment using closed reduction and plaster immobilisation.

View Article and Find Full Text PDF

Aim: To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.

Methods: A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.

View Article and Find Full Text PDF

Unlabelled: Fractures of the distal radius are common and occur in all age groups. The incidence is high in older populations due to osteoporosis and increased falls risk. Considerable practice variation exists in the management of distal radius fractures in older patients ranging from closed reduction with cast immobilisation to open reduction with plate fixation.

View Article and Find Full Text PDF

Sacral fracture with spino-pelvic  dissociation is a rare and unstable injury caused by high-energy trauma, often with serious haemodynamic and neurological implications. Diagnosis is easily delayed or missed as it is often masked by severe associated injuries. Here, we present an unusual case of spino-pelvic dissociation sustained during a seizure episode in a young epileptic patient on long-term anticonvulsant therapy with previous thoracolumbar spinal arthrodesis.

View Article and Find Full Text PDF

Aim: To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.

Methods: A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate ( = 29), or another treatment modality ( = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk.

View Article and Find Full Text PDF

Aim: To review our outcomes and compare the results of the Less Invasive Stabilization System (LISS) to other implants for distal femur fracture management at a regional Australian hospital.

Methods: The LISS is a novel implant for the management of distal femur fractures. It is, however, technically demanding and treatment results have not yet been assessed outside tertiary centres.

View Article and Find Full Text PDF

Introduction: Currently available volar locking plates for the treatment of distal radius fractures incorporate at least two distal screw rows for fixation of the metaphyseal fragment and have a variable-angle locking mechanism which allows placement of the screws in various directions There is, however no evidence that these plates translate into better outcomes or have superior biomechanical properties to first generation plates, which had a single distal screw row and fixed-angle locking. The aim of our biomechanical study was to compare fixed-angle single-row plates with variable-angle multi-row plates to clarify the optimal number of locking screws.

Materials And Methods: Five different plate-screw combinations of three different manufacturers were tested, each group consisting of five synthetic fourth generation distal radius bones.

View Article and Find Full Text PDF

Introduction: Cervical spine radiography may be over-utilised in an emergency department setting. The Canadian C-Spine Rule has been developed to reduce unnecessary radiography. Our aim was to retrospectively determine the proportion of cervical spine radiographs requested through the emergency department for trauma patients that were clinically indicated, according to the Canadian C-Spine Rule.

View Article and Find Full Text PDF

Objectives:   Surgical site infection (SSI) following minor surgery contributes to patient morbidity and compromises cosmetic outcomes. The purpose of this study was to determine the incidence of and risk factors for SSI after dermatological surgery in general practice.

Methods:   A prospective, observational study which assessed infection among 972 patients was conducted in regional north Queensland, Australia.

View Article and Find Full Text PDF

Background: The current options for plate-screw combinations in volar locking distal radius plates used for the treatment of distal radius fractures are either plates with a single distal screw row or plates with multiple distal screw rows. Additionally, the screws themselves may have either fixed angle locking or polyaxial locking mechanisms. To date, there is no evidence or consensus regarding the optimal plate-screw combination.

View Article and Find Full Text PDF

Introduction: Volar fixed-angle plating is a popular treatment for unstable distal radius fractures. Despite the availability of plating systems for treating distal radius fractures, little is known about the mechanical properties of multidirectional fixed-angle plates. The aim of this study was to compare the primary fixation stability of three possible screw configurations in a distal extra-articular fracture model using a multidirectional fixed-angle plate with metaphyseal cancellous screws distally.

View Article and Find Full Text PDF

Background: Distal radius fractures represent the most common fractures in adult individuals. Volar fixed-angle plating has become a popular modality for treating unstable distal radius fractures. Most of the plates allow insertion of either threaded locking screws or smooth locking pegs.

View Article and Find Full Text PDF

Background: Though, volar fixed-angle plating has become increasingly popular to treat distal radius fractures no studies are available comparing the mechanical properties of different screw configurations to fix the plate to the shaft. The aim of the present study was to evaluate the effect of an additional locking screw directly proximal to the fracture site and to assess if such a screw might be protective against secondary loss of reduction after volar fixed-angle plating.

Methods: Ten Sawbones radii were used to simulate an extra-articular distal radius fracture model (AO/OTA 23-A3).

View Article and Find Full Text PDF

Objective: To determine the effectiveness of a single application of topical chloramphenicol ointment in preventing wound infection after minor dermatological surgery.

Design: Prospective randomised placebo controlled double blind multicentre trial.

Setting: Primary care in a regional centre in Queensland, Australia.

View Article and Find Full Text PDF

Purpose: Treatment of extension fractures of the distal radius with volar fixed-angle plates has become increasingly popular in the past 2 years. It has been observed clinically that placement of the distal screws as close as possible to the subchondral zone is crucial to maintain radial length after surgery. The purposes of this study were (1) to evaluate radial shortening after plating with regard to plate position and (2) to evaluate whether plate position has an influence on the strength and rigidity of the plate-screw construct.

View Article and Find Full Text PDF

We developed a locking screw plate system for the stabilisation of distal radial fractures, which can be inserted through a standard volar approach and in which the locking mechanism allows early post-operative mobilisation. Forty-nine patients with 50 fractures underwent surgical treatment; 66% were type C fractures. The mean follow-up was 26 months.

View Article and Find Full Text PDF

Introduction: We performed this study in order to assess epidemiology and current practice of treatment of severe traumatic brain injury in Austria. Our survey followed the methods of a study published by J. Ghajar et al in the USA in 1995 and we compared the results to the Brain Trauma Foundation's "Guidelines For The Management Of Severe Head Injury".

View Article and Find Full Text PDF