Background: Silicon-based micro-pillar substrates (MPS), as three-dimensional cell culture platforms with vertically aligned micro-patterned scaffolding structures, are known to facilitate high-quality growth and morphology of dorsal root ganglion (DRG) sensory neurons, promote neurite outgrowth and enhance neurite alignment. However, the electrophysiological aspects of DRG neurons cultured on silicon MPSs have not been thoroughly investigated, which is of greatest importance to ensure that such substrates do not disrupt neuronal homeostasis and function before their widespread adoption in diverse biomedical applications.
New Method: We conducted whole-cell patch-clamp recordings to explore the electrophysiological properties of DRG neurons cultured on MPS arrays, utilizing a custom-made upright patch-clamp setup.
Compound nerve action potentials (CNAPs) were used as a metric to assess the stimulation performance of a novel high-density, transverse, intrafascicular electrode in rat models. We show characteristic CNAPs recorded from distally implanted cuff electrodes. Evaluation of the CNAPs as a function of stimulus current and calculation of recruitment plots were used to obtain a qualitative approximation of the neural interface's placement and orientation inside the nerve.
View Article and Find Full Text PDFSpatially resolved transfection, intracellular delivery of proteins and nucleic acids, has the potential to drastically speed up the discovery of biologically active cargos, for instance for the development of cell therapies or new genome engineering tools. We recently demonstrated the use of a high-density microelectrode array for the targeted electrotransfection of cells grown on its surface, a process called High-Definition Electroporation (HD-EP). We also developed a framework based on Design of Experiments to quickly establish optimized electroporation conditions across five different electrical pulse parameters.
View Article and Find Full Text PDFBackground: The directionality analysis of the neurite outgrowths is an important methodology in neuroscience, especially in determining the behavior of neurons grown on silicon substrates.
New Method: Here we aimed to describe the methodology for quantification of the directionality of neurites based on the Fast Fourier Transform (FFT). We performed an image analysis case study that incorporates several software solutions and provides a rapid and precise technique to determine the directionality of neurites.
Intracellular delivery is critical for a plethora of biomedical applications, including mRNA transfection and gene editing. High transfection efficiency and low cytotoxicity, however, are often beyond the capabilities of bulk techniques and synonymous with extensive empirical optimization. Moreover, bulk techniques are not amenable to large screening applications.
View Article and Find Full Text PDFThe use of animals in neuroscience and biomedical research remains controversial. Policy is built around the "3R" principle of "Refining, Reducing and Replacing" animal experiments, and across the globe, different initiatives stimulate the use of animal-free methods. Based on an extensive literature screen to map the development and adoption of animal-free methods in Alzheimer's and Parkinson's disease research, we find that at least two in three examined studies rely on animals or on animal-derived models.
View Article and Find Full Text PDFDuring adult rodent life, newborn neurons are added to the olfactory bulb (OB) in a tightly controlled manner. Upon arrival in the OB, input synapses from the local bulbar network and the higher olfactory cortex precede the formation of functional output synapses, indicating a possible role for these regions in newborn neuron survival. An interplay between the environment and the piriform cortex in the regulation of newborn neuron survival has been suggested.
View Article and Find Full Text PDFJ Control Release
February 2021
Advances in gene editing and cell therapies have recently led to outstanding clinical successes. However, the lack of a cost-effective manufacturing process prevents the democratization of these innovative medical tools. Due to the common use of viral vectors, the step of transfection in which cells are engineered to gain new functions, is a major bottleneck in making safe and affordable cell products.
View Article and Find Full Text PDFWe present a compressive lens-free technique that performs tomographic imaging across a cubic millimeter-scale volume from highly sparse data. Compared with existing lens-free 3D microscopy systems, our method requires an order of magnitude fewer multi-angle illuminations for tomographic reconstruction, leading to a compact, cost-effective and scanning-free setup with a reduced data acquisition time to enable high-throughput 3D imaging of dynamic biological processes. We apply a fast proximal gradient algorithm with composite regularization to address the ill-posed tomographic inverse problem.
View Article and Find Full Text PDFJ Pharmacol Toxicol Methods
September 2020
Multi-electrode arrays, both active or passive, emerged as ideal technologies to unveil intricated electrophysiological dynamics of cells and tissues. Active MEAs, designed using complementary metal oxide semiconductor technology (CMOS), stand over passive devices thanks to the possibility of achieving single-cell resolution, the reduced electrode size, the reduced crosstalk and the higher functionality and portability. Nevertheless, most of the reported CMOS MEA systems mainly rely on a single operational modality, which strongly hampers the applicability range of a single device.
View Article and Find Full Text PDFObjective: Assessment of the relationship between the topographical organization of silicon micro-pillar surfaces (MPS) on guidance and neural alignment of adult spiral ganglion neurons (SGN) and use of the otosurgical approach as an alternative for the extraction and isolation of SGNs from adult guinea pigs.
Approach: SGNs from adult guinea pigs were isolated using conventional and otosurgical approach for in vitro cell culturing on MPS of various micro-pillar widths (1-5.6 µm) and spacing (0.
Lens-free holographic microscopy (LFHM) provides a cost-effective tool for large field-of-view imaging in various biomedical applications. However, due to the unit optical magnification, its spatial resolution is limited by the pixel size of the imager. Pixel super-resolution (PSR) technique tackles this problem by using a series of sub-pixel shifted low-resolution (LR) lens-free holograms to form the high-resolution (HR) hologram.
View Article and Find Full Text PDFCurr Pharm Des
November 2019
Neurodegenerative disorders are related to the progressive functional loss of the brain, often connected to emotional and physical disability and, ultimately, to death. These disorders, strongly connected to the aging process, are becoming increasingly more relevant due to the increase of life expectancy. Current pharmaceutical treatments poorly tackle these diseases, mainly acting only on their symptomology.
View Article and Find Full Text PDFThe skin is the largest and most exposed organ in the human body. Not only it is involved in numerous biological processes essential for life but also it represents a significant endpoint for the application of pharmaceuticals. The area of in vitro skin tissue engineering has been progressing extensively in recent years.
View Article and Find Full Text PDFThis study investigated micro-patterned, high-density complementary metal-oxide-semiconductor (CMOS) electrode array to be used as biologically permissive environment for organization, guidance and electrical stimulation of spiral ganglion neurons (SGN). SGNs extracted and isolated from cochleae of P5-P7 rat pups and adult guinea pigs were cultured 1, 4 and 7 days in vitro on glass coverslips (control) and CMOS electrode array. The cultures were analyzed visually and immunohistochemically for SGN presence, outgrowth, neurite alignment, neurite length, neurite asymmetry as well as the contact of a neuronal soma and neurites with the micro-electrodes.
View Article and Find Full Text PDFMicroelectrode arrays (MEAs) have proved to be useful tools for characterizing electrically active cells such as cardiomyocytes and neurons. While there exist a number of integrated electronic chips for recording from small populations or even single cells, they rely primarily on the interface between the cells and 2D flat electrodes. Here, an approach that utilizes residual stress-based self-folding to create individually addressable multielectrode interfaces that wrap around the cell in 3D and function as an electrical shell-like recording device is described.
View Article and Find Full Text PDFThe high rate of drug attrition caused by cardiotoxicity is a major challenge for drug development. Here, we developed a reflective lens-free imaging (RLFI) approach to non-invasively record cell deformation in cardiac monolayers with high temporal (169 fps) and non-reconstructed spatial resolution (352 µm) over a field-of-view of maximally 57 mm. The method is compatible with opaque surfaces and silicon-based devices.
View Article and Find Full Text PDFOptogenetic manipulations are widely used for investigating the contribution of genetically identified cell types to behavior. Simultaneous electrophysiological recordings are less common, although they are critical for characterizing the specific impact of optogenetic manipulations on neural circuits in vivo. This is at least in part because combining photostimulation with large-scale electrophysiological recordings remains technically challenging, which also poses a limitation for performing extracellular identification experiments.
View Article and Find Full Text PDFDeep Brain Stimulation (DBS) has evolved into a well-accepted add-on treatment for patients with severe Parkinsons disease as well as for other chronic neurological conditions. The focal action of electrical stimulation can yield better responses and it exposes the patient to fewer side effects compared to pharmaceuticals distributed throughout the body toward the brain. On the other hand, the current practice of DBS is hampered by the relatively coarse level of neuromodulation achieved.
View Article and Find Full Text PDFMany studies have shown that the topography of the substrate on which neurons are cultured can promote neuronal adhesion and guide neurite outgrowth in the same direction as the underlying topography. To investigate this effect, isotropic substrate-complementary metal-oxide-semiconductor (CMOS) chips were used as one example of microelectrode arrays (MEAs) for directing neurite growth of spiral ganglion neurons. Neurons were isolated from 5 to 7-day-old rat pups, cultured 1 day in vitro (DIV) and 4 DIV, and then fixed with 4% paraformaldehyde.
View Article and Find Full Text PDFDrug-induced cardiotoxicity poses a negative impact on public health and drug development. Cardiac safety pharmacology issues urged for the preclinical assessment of drug-induced ventricular arrhythmia leading to the design of several in vitro electrophysiological screening assays. In general, patch clamp systems allow for intracellular recordings, while multi-electrode array (MEA) technology detect extracellular activity.
View Article and Find Full Text PDFSmall soluble species of amyloid-beta (Aβ) formed during early peptide aggregation stages are responsible for several neurotoxic mechanisms relevant to the pathology of Alzheimer's disease (AD), although their interaction with the neuronal membrane is not completely understood. This study quantifies the changes in the neuronal membrane elasticity induced by treatment with the two most common Aβ isoforms found in AD brains: Aβ40 and Aβ42. Using quantitative atomic force microscopy (AFM), we measured for the first time the static elastic modulus of living primary hippocampal neurons treated with pre-aggregated Aβ40 and Aβ42 soluble species.
View Article and Find Full Text PDFModulation of a group of cells or tissue needs to be very precise in order to exercise effective control over the cell population under investigation. Optogenetic tools have already demonstrated to be of great value in the study of neuronal circuits and in neuromodulation. Ideally, they should permit very accurate resolution, preferably down to the single cell level.
View Article and Find Full Text PDF