Publications by authors named "Drakakis E"

Autism spectrum disorder (ASD) is a chronic neurological disorder with the severity directly linked to the diagnosis age. The severity can be reduced if diagnosis and intervention are early (age < 2 years). This work presents a novel ear-worn wearable EEG system designed to aid in the early detection of ASD.

View Article and Find Full Text PDF

The literature on voltammetry and electrochemical impedance spectroscopy (EIS) recognises the importance of using large-amplitude sinusoidal perturbations to better characterise electrochemical systems. To identify the parameters of a given reaction, various electrochemical models with different sets of values are simulated and compared against the experimental data to determine the best-fit set of parameters. However, the process of solving these nonlinear models is computationally expensive.

View Article and Find Full Text PDF

Background: Ablation of autonomic ectopy-triggering ganglionated plexuses (ET-GP) has been used to treat paroxysmal atrial fibrillation (AF). It is not known if ET-GP localisation is reproducible between different stimulators or whether ET-GP can be mapped and ablated in persistent AF. We tested the reproducibility of the left atrial ET-GP location using different high-frequency high-output stimulators in AF.

View Article and Find Full Text PDF

Aims: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS.

Methods And Results: Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts.

View Article and Find Full Text PDF

Introduction/aims: Fasciculations are an early clinical hallmark of amyotrophic lateral sclerosis (ALS), amenable to detection by high-density surface electromyography (HDSEMG). In conjunction with the Surface Potential Quantification Engine (SPiQE), HDSEMG offers improved spatial resolution for the analysis of fasciculations. This study aims to establish an optimal recording duration to enable longitudinal remote monitoring in the home.

View Article and Find Full Text PDF

Objective: We present Myolink, a portable, modular, low-noise electrophysiology amplifier optimized for high-density surface electromyogram (HD sEMG) acquisition.

Methods: Myolink consists of 4 modules. Each 10 × 8 cm module can concurrently acquire 32 unipolar electrode potentials at sampling rates of up to 8 kHz with 24-bit resolution.

View Article and Find Full Text PDF

Key Points: Amyotrophic lateral sclerosis (ALS) is an incurable neurodegenerative disorder of motor neurons, carrying a short survival. High-density motor unit recordings permit analysis of motor unit size (amplitude) and firing behaviour (afterhyperpolarization duration and muscle fibre conduction velocity). Serial recordings from biceps brachii indicated that motor units fired faster and with greater amplitude as disease progressed.

View Article and Find Full Text PDF

Delayed diagnosis of amyotrophic lateral sclerosis prevents early entry into clinical trials at a time when neuroprotective therapies would be most effective. Fasciculations are an early hallmark of amyotrophic lateral sclerosis, preceding muscle weakness and atrophy. To assess the potential diagnostic utility of fasciculations measured by high-density surface electromyography, we carried out 30-min biceps brachii recordings in 39 patients with amyotrophic lateral sclerosis, 7 patients with benign fasciculation syndrome, 1 patient with multifocal motor neuropathy and 17 healthy individuals.

View Article and Find Full Text PDF

Introduction: Prognostic uncertainty in amyotrophic lateral sclerosis (ALS) confounds clinical management planning, patient counseling, and trial stratification. Fasciculations are an early clinical hallmark of disease and can be quantified noninvasively. Using an innovative analytical method, we correlated novel fasciculation parameters with a predictive survival model.

View Article and Find Full Text PDF

Amyotrophic lateral sclerosis is a devastating neurodegenerative disease with a median survival of 3 years from symptom onset. Accessible and reliable biomarkers of motor neuron decline are urgently needed to quicken the pace of drug discovery. Fasciculations represent an early pathophysiological hallmark of amyotrophic lateral sclerosis and can be reliably detected by high-density surface electromyography.

View Article and Find Full Text PDF

Background: Traumatic Brain Injury (TBI) is a leading cause of fatality and disability worldwide, partly due to the occurrence of secondary injury and late interventions. Correct diagnosis and timely monitoring ensure effective medical intervention aimed at improving clinical outcome. However, due to the limitations in size and cost of current ambulatory bioinstruments, they cannot be used to monitor patients who may still be at risk of secondary injury outside the ICU.

View Article and Find Full Text PDF

Introduction: Fasciculations represent early neuronal hyperexcitability in amyotrophic lateral sclerosis (ALS). To aid calibration as a disease biomarker, we set out to characterize the daytime variability of fasciculation firing.

Methods: Fasciculation awareness scores were compiled from 19 ALS patients.

View Article and Find Full Text PDF

Background: It is widely accepted by the scientific community that bioelectrical signals, which can be used for the identification of neurophysiological biomarkers indicative of a diseased or pathological state, could direct patient treatment towards more effective therapeutic strategies. However, the design and realisation of an instrument that can precisely record weak bioelectrical signals in the presence of strong interference stemming from a noisy clinical environment is one of the most difficult challenges associated with the strategy of monitoring bioelectrical signals for diagnostic purposes. Moreover, since patients often have to cope with the problem of limited mobility being connected to bulky and mains-powered instruments, there is a growing demand for small-sized, high-performance and ambulatory biopotential acquisition systems in the Intensive Care Unit (ICU) and in High-dependency wards.

View Article and Find Full Text PDF

Objectives: Fasciculations are a clinical hallmark of amyotrophic lateral sclerosis (ALS). The Surface Potential Quantification Engine (SPiQE) is a novel analytical tool to identify fasciculation potentials from high-density surface electromyography (HDSEMG). This method was accurate on relaxed recordings amidst fluctuating noise levels.

View Article and Find Full Text PDF

Objective: Recording of local field potentials (LFPs) during deep brain stimulation (DBS) is necessary to investigate the instantaneous brain response to stimulation, minimize time delays for closed-loop neurostimulation and maximise the available neural data. To our knowledge, existing recording systems lack the ability to provide artefact-free high-frequency (>100 Hz) LFP recordings during DBS in real time primarily because of the contamination of the neural signals of interest by the stimulation artefacts.

Approach: To solve this problem, we designed and developed a novel, low-noise and versatile analog front-end (AFE) that uses a high-order (8th) analog Chebyshev notch filter to suppress the artefacts originating from the stimulation frequency.

View Article and Find Full Text PDF

Objectives: Fasciculations are a clinical hallmark of amyotrophic lateral sclerosis (ALS). Compared to concentric needle EMG, high-density surface EMG (HDSEMG) is non-invasive and records fasciculation potentials (FPs) from greater muscle volumes over longer durations. To detect and characterise FPs from vast data sets generated by serial HDSEMG, we developed an automated analytical tool.

View Article and Find Full Text PDF

Currently, there are no valid pre-operatively established biomarkers or algorithms that can accurately predict surgical and clinical outcome for patients with advanced epithelial ovarian cancer (EOC). In this study, we suggest that profiling of tumour parameters such as bioelectrical-potential and metabolites, detectable by electronic sensors, could facilitate the future development of devices to better monitor disease and predict surgical and treatment outcomes. Biopotential was recorded, using a potentiometric measurement system, in ex vivo paired non-cancerous and cancerous omental tissues from advanced stage EOC (n = 36), and lysates collected for metabolite measurement by microdialysis.

View Article and Find Full Text PDF

A quadrature synthetic aperture front-end receiver for B-mode ultrasound imaging is presented. The receiver targets small-scale imaging applications such as capsule endoscopy and low-cost portable devices. System complexity, area, power consumption, and cost are minimized using synthetic aperture beamforming (SAB), whereby signals are processed in a sequential manner using only a single channel.

View Article and Find Full Text PDF

Background: Point of care ultrasonography has been the focus of extensive research over the past few decades. Miniaturised, wireless systems have been envisaged for new application areas, such as capsule endoscopy, implantable ultrasound and wearable ultrasound. The hardware constraints of such small-scale systems are severe, and tradeoffs between power consumption, size, data bandwidth and cost must be carefully balanced.

View Article and Find Full Text PDF

This paper presents the first application specific integrated chip (ASIC) for the monitoring of patients who have suffered a Traumatic Brain Injury (TBI). By monitoring the neurophysiological (ECoG) and neurochemical (glucose, lactate and potassium) signals of the injured human brain tissue, it is possible to detect spreading depolarisations, which have been shown to be associated with poor TBI patient outcome. This paper describes the testing of a new 7.

View Article and Find Full Text PDF
Article Synopsis
  • This paper discusses a new method for storing clinical microdialysis samples using tubing, providing better options for delayed analysis compared to traditional sampling methods.
  • Samples stored in this tubing remain stable for up to 72 days when kept at -80 °C, allowing for consistent results over time.
  • The authors present a general model to help choose the right tubing parameters based on storage time and flow rate, ensuring effective performance without causing leaks in the microdialysis probe.
View Article and Find Full Text PDF

Recent studies have demonstrated that calcium is a widespread intracellular ion that controls a wide range of temporal dynamics in the mammalian body. The simulation and validation of such studies using experimental data would benefit from a fast large scale simulation and modelling tool. This paper presents a compact and fully reconfigurable cellular calcium model capable of mimicking Hopf bifurcation phenomenon and various nonlinear responses of the biological calcium dynamics.

View Article and Find Full Text PDF

Optical neuron stimulation arrays are important for both in-vitro biology and retinal prosthetic biomedical applications. Hence, in this work, we present an 8100 pixel high radiance photonic stimulator. The chip module vertically combines custom made gallium nitride μ LEDs with a CMOS application specific integrated circuit.

View Article and Find Full Text PDF