Objectives: Pancreatic adenocarcinoma is frequently associated with pain requiring opioid therapy. Opioids, however, have been implicated in causing tumor progression, ultimately shortening survival. We examined the impact of pain, opioid use, and the mu-opioid receptor (MOP-R) expression in tumor tissue on progression-free survival and overall survival of patients with metastatic pancreatic cancer.
View Article and Find Full Text PDFGraphene has been known to possess exceptional mechanical properties, including its extremely high Young's modulus and atomic layer thickness. Although there are several reported fiber optic pressure sensors using graphene film, a key question that is not well understood is how the suspended graphene film interacts with the backing air cavity and affects the sensor performance. Based on our previous analytical model, we will show that the sensor performance suffers due to the significantly reduced mechanical sensitivity by the backing cavity.
View Article and Find Full Text PDFPiston gauges or pressure balances are important primary standards for the realization of the SI unit of pressure, the pascal. Because of their long-term stability, they are also used as secondary or working standards in the dissemination of the pressure scale. The National Institute of Standards and Technology (NIST) operates and maintains a calibration service for these devices, and has recently undertaken a modernization effort.
View Article and Find Full Text PDFWe demonstrate a novel miniature multi-parameter sensing device based on a plasmonic interferometer fabricated on a fiber facet in the optical communication wavelength range. This device enables the coupling between surface plasmon resonance and plasmonic interference in the structure, which are the two essential mechanisms for multi-parameter sensing. We experimentally show that these two mechanisms have distinctive responses to temperature and refractive index, rendering the device the capability of simultaneous temperature and refractive index measurement on an ultra-miniature form factor.
View Article and Find Full Text PDFJ Res Natl Inst Stand Technol
May 2016
The National Institute of Standards and Technology (NIST) has redefined its gas pressure scale, up to 17 MPa, based on two primary standard piston gauges. The primary standard piston gauges are 35.8 mm in diameter and operate from 20 kPa to 1 MPa.
View Article and Find Full Text PDFWe used a capacitive technique to determine the radial clearance between the piston and cylinder of a gas piston gauge. This method determines the effective area of a piston gauge pressure standard, independent of calibration against another piston gauge or manometer, as long as the diameter of the piston is dimensionally measured. It also allows an independent determination of piston gauge distortion due to pressure.
View Article and Find Full Text PDFBackground: Approximately 4 million US travelers to developing countries are ill enough to seek health care, with 1500 malaria cases reported in the United States annually. The diagnosis of malaria is frequently delayed because of the time required to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful.
View Article and Find Full Text PDFBiochem Biophys Res Commun
June 2005
The beta-amyloids (abetas) are the major components of the plaque observed in the brains of patients with Alzheimer's disease. The conundrum is that although they are produced in everyone during the posttranslational processing in the endoplasmic reticulum (ER) of the amyloid precursor protein (APP), deposits are only observed in the elderly. Our work suggests that normals have a carrier protein(s) keeping them in solution.
View Article and Find Full Text PDF