Publications by authors named "Doreen Markewitz"

Portable photocatalytic air cleaners were investigated in 24 and 48 m(3) emission test chambers with regard to efficiency and by-product generation. For this purpose, formaldehyde, decane, 1,2-dichlorobenzene, toluene, α-pinene and heptanal were doped at sub-ppm concentration levels into the chambers individually and in mixtures. By way of specified test protocols, efficiencies could be distinguished but were strongly dependant on the choice of test compounds, especially on whether single or multi compound dosing was used, and on long-term effects.

View Article and Find Full Text PDF

Different analytical devices were tested and evaluated for their suitability of breath gas analysis by examining the physiological parameters and chemical substances in the exhaled breath of ten healthy probands during light cycling in dependence of methanol-rich nutrition. The probands exercised under normal breathing conditions on a bicycle ergometer. Breath air was exhaled into a glass cylinder and collected under steady-state conditions.

View Article and Find Full Text PDF