Purpose: To present outcomes of transurethral removal (TUR) of intravesical or intraurethral mesh after midurethral slings.
Materials And Methods: This was a retrospective chart review of 23 consecutive women: 20 with intravesical mesh and 3 with intraurethral mesh.
Results: To remove the mesh, transurethral resection with an electrode loop (TUR-E) was used in 16 women and transurethral resection with a holmium laser (TUR-H) was used in 7.