This paper presents a general framework for assessing imaging systems and image-analysis methods on the basis of therapeutic rather than diagnostic efficacy. By analogy to receiver operating characteristic (ROC) curves, it utilizes the Therapy Operating Characteristic or TOC curve, which is a plot of the probability of tumor control vs. the probability of normal-tissue complications as the overall level of a radiotherapy treatment beam is varied.
View Article and Find Full Text PDFImaging β rays in vivo will help to advance microdosimetry and radiopharmaceutical development. In an earlier paper [1], we reported a newly developed system capable of directly imaging high-energy electron emissions in small animals in vivo. In this paper, we have thoroughly characterized the performance of the system.
View Article and Find Full Text PDFSilicon double-sided strip detectors offer outstanding instrinsic spatial resolution with reasonable detection efficiency for iodine-125 emissions. This spatial resolution allows for multiple-pinhole imaging at low magnification, minimizing the problem of multiplexing. We have conducted imaging studies using a prototype system that utilizes a detector of 300-micrometer thickness and 50-micrometer strip pitch together with a 23-pinhole collimator.
View Article and Find Full Text PDFIn this paper, we consider a prototype of an adaptive SPECT system, and we use simulation to objectively assess the system's performance with respect to a conventional, non-adaptive SPECT system. Objective performance assessment is investigated for a clinically relevant task: the detection of tumor necrosis at a known location and in a random lumpy background. The iterative maximum-likelihood expectation-maximization (MLEM) algorithm is used to perform image reconstruction.
View Article and Find Full Text PDFThe authors have designed and constructed a small-animal adaptive SPECT imaging system as a prototype for quantifying the potential benefit of adaptive SPECT imaging over the traditional fixed geometry approach. The optical design of the system is based on filling the detector with the region of interest for each viewing angle, maximizing the sensitivity, and optimizing the resolution in the projection images. Additional feedback rules for determining the optimal geometry of the system can be easily added to the existing control software.
View Article and Find Full Text PDFIEEE Nucl Sci Symp Conf Rec (1997)
January 2007
We previously demonstrated the feasibility of using silicon double-sided strip detectors (DSSDs) for SPECT imaging of the activity distribution of iodine-125 using a 300-micrometer thick detector. Based on this experience, we now have developed fully customized silicon DSSDs and associated readout electronics with the intent of developing a multi-pinhole SPECT system. Each DSSD has a 60.
View Article and Find Full Text PDFWe have designed and built an inexpensive, high-resolution, tomographic imaging system, dubbed the multi-module, multi-resolution system, or M3R. Slots machined into the system shielding allow for the interchange of pinhole plates, enabling the system to operate over a wide range of magnifications and with virtually any desired pinhole configuration. The flexibility of the system allows system optimization for specific imaging tasks and also allows for modifications necessary due to improved detectors, electronics, and knowledge of system construction (e.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
January 2007
Evaluation of imaging hardware represents a vital component of system design. In small-animal SPECT imaging, this evaluation has become increasingly difficult with the emergence of multi-pinhole apertures and adaptive, or patient-specific, imaging. This paper will describe two methods for hardware evaluation using reconstructed images.
View Article and Find Full Text PDFThe first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.
View Article and Find Full Text PDFBackground: (99m)Tc-sestamibi (MIBI) and (99m)Tc-tetrofosmin (TF) are avid transport substrates recognized by the multidrug resistance (MDR) P-glycoprotein (Pgp). This study was designed to compare the properties of MIBI and TF in assessing the inhibition of Pgp by PSC833 in severe combined immunodeficient mice bearing MCF7 human breast tumors using SPECT imaging.
Methods: Animals with drug-sensitive (MCF/WT) and drug-resistant (MCF7/AdrR) tumors were treated by PSC833 and by carrier vehicle 1 h before imaging, respectively.
Proc SPIE Int Soc Opt Eng
February 2005
We have previously utilized lumpy object models and simulated imaging systems in conjunction with the ideal observer to compute figures of merit for hardware optimization. In this paper, we describe the development of methods and phantoms necessary to validate or experimentally carry out these optimizations. Our study was conducted on a four-camera small-animal SPECT system that employs interchangeable pinhole plates to operate under a variety of pinhole configurations and magnifications (representing optimizable system parameters).
View Article and Find Full Text PDFWe outline the design of a new small-animal PET system. This system employs modular scintillation cameras composed of nine PMTs coupled by a light guide to a monolithic NaI(Tl) scintillation crystal. The basic principles of the PET system are presented along with an overview of the electronics and position-estimation scheme.
View Article and Find Full Text PDFUnlabelled: (99m)Tc-Glucarate ((99m)Tc-GLA) is a novel infarct-avid imaging agent. The aim of this study was to evaluate the role of (99m)Tc-GLA for assessing the severity of myocardial ischemia-reperfusion injury in rat heart models exposed to varied durations of left coronary artery (LCA) occlusion with reperfusion using a high-resolution SPECT system, FASTSPECT. We also wanted to clarify whether a rapid sequence of 3-dimensional imaging with FASTSPECT can quantify uptake and washout kinetics of cardiovascular imaging agents in small-animal heart models.
View Article and Find Full Text PDFBackground And Aim: Previous studies have showed that 99mTc labelled glucarate (GLA) might be an agent for non-invasive detection of breast tumours. In xenografted BT20 breast tumours, GLA was found to have higher uptake than 99mTc sestamibi (MIBI). It is unclear whether GLA can localize in all cell line breast cancer xenografts, as well as breast tumours with multidrug resistance (MDR).
View Article and Find Full Text PDFFastSPECT II is a recently commissioned 16-camera small-animal SPECT imager built with modular scintillation cameras and list-mode data-acquisition electronics. The instrument is housed in a lead-shielded enclosure and has exchangeable aperture assemblies and adjustable camera positions for selection of magnification, pinhole size, and field of view. The calibration of individual cameras and measurement of an overall system imaging matrix (1 mm(3) voxels) are supported via a five-axis motion-control system.
View Article and Find Full Text PDFWe have developed a dual-modality CT/SPECT imaging system for small-animal imaging applications. The X-ray system comprises a commercially available micro-focus X-ray tube and a CCD-based X-ray camera. X-ray transmission measurements are performed based on cone-beam geometry.
View Article and Find Full Text PDFImaging recognition of multidrug-resistance by 99mTc-labeled sestamibi, tetrofosmin and furifosmin in mice bearing human breast tumors was evaluated using a high-resolution SPECT, FASTSPECT. Imaging results showed that the washout rates in drug-resistant MCF7/D40 tumors were significantly greater than that in drug-sensitive MCF7/S tumors. Furifosmin exhibited greater washout from both MCF7/S and MCF7/D40 than sestamibi, while tetrofosmin washout was greater than sestamibi in MCF7/D40 only.
View Article and Find Full Text PDFImaging is often used for the purpose of estimating the value of some parameter of interest. For example, a cardiologist may measure the ejection fraction (EF) of the heart to quantify how much blood is being pumped out of the heart on each stroke. In clinical practice, however, it is difficult to evaluate an estimation method because the gold standard is not known, e.
View Article and Find Full Text PDFUnlabelled: The purpose of this study was to develop an in vivo imaging protocol for a high-resolution stationary SPECT system, called FASTSPECT, in a rat heart model of ischemia-reperfusion (IR) and to compare 99mTc-sestamibi imaging and triphenyltetrazolium chloride (TTC) staining for reliability and accuracy in the measurement of myocardial infarcts.
Methods: FASTSPECT consists of 24 modular cameras and a 24-pinhole aperture with 1.5-mm spatial resolution and 13.
IEEE Nucl Sci Symp Conf Rec (1997)
November 2002
We have constructed a SPECT system for small animals that utilizes eight CdZnTe pixel detectors. The eight detectors are arranged in a single octagonal ring, where each views the object to be imaged through a single pinhole. Additional projections are obtained via rotation of the animal.
View Article and Find Full Text PDFWe have used an approximate method developed by Barrett, Wilson, and Tsui for finding the ensemble statistics of the Maximum Likelihood-Expectation Maximization algorithm to compute task-dependent figures of merit as a function of stopping point. For comparison, human-observer performance was assessed through conventional psychophysics.The results of our studies show the dependence of the optimal stopping point of the algorithm on the detection task.
View Article and Find Full Text PDF