Background: Emergency surgery has become an increasingly rare event after percutaneous coronary intervention (PCI). There have been no randomized trials evaluating whether cardiac surgery services on-site are essential for patient safety and optimal outcomes during and after PCI.
Study Design: The MASS COMM trial (ClinicalTrials.
Objectives: We conducted the "TAXUS Woman" analysis to assess the influence of sex on long-term outcomes after percutaneous coronary intervention using paclitaxel-eluting stents (PES) in a broad spectrum of patients.
Background: Previous studies indicate that the sex gap suggesting worse outcomes in women has narrowed. However, limited data are available on long-term sex-based outcomes with drug-eluting stents despite their extensive use in current practice.
Introduction: Interventional cardiology, with large numbers of complex procedures and potentially serious complications, stands out as an obvious discipline in which to apply simulation to help prevent medical errors. The objective of the study was to determine whether it is feasible to develop a valid and reliable evaluation approach using medical simulation to assess technical and cognitive skills of physicians performing coronary interventions.
Methods: Clinical case scenarios were developed by a committee of subject matter experts, who defined key decision nodes, such as stent positioning, and introduced unanticipated complications, such as coronary perforation.
Objectives: The aim of this study was to study the long-term clinical effects of routine angiographic follow-up and related reintervention after drug-eluting stenting.
Background: Prior stent trials have shown that protocol-mandated angiographic follow-up increases repeat interventions compared with clinical follow-up alone. The long-term clinical impact of this practice is unknown.
Objectives: The pivotal TAXUS IV (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent) trial evaluated the long-term safety and effectiveness of the paclitaxel-eluting stent (PES) compared with an otherwise identical bare-metal stent (BMS) in a relatively uncomplicated population of patients with a single de novo lesion in a native coronary vessel, treated between March and July 2002.
Background: Long-term follow-up is required to determine whether the early safety and efficacy of drug-eluting stents are maintained.
Methods: The primary end point of this prospective, randomized, double-blind trial was 9-month ischemia-driven target vessel revascularization (TVR) for PES versus the BMS control.
Background: Stent thrombosis (ST) is an uncommon but serious complication of drug-eluting and bare metal stents. To assess drug-eluting stent ST in contemporary practice, we analyzed 2-year data from the 7492-patient ARRIVE registry.
Methods And Results: Patients were enrolled at the initiation of percutaneous coronary intervention with no inclusion/exclusion criteria beyond use of the paclitaxel-eluting TAXUS stent.
Background: Although drug-eluting stents have become a mainstay of percutaneous coronary intervention, information about drug-eluting stents outcomes in elderly patients is limited. Data from the paclitaxel-eluting stent (PES) trials and registries were pooled to assess PES benefits relative to advancing patient age, including comparison with bare-metal stents.
Methods And Results: Data from 5 randomized trials (2271 patients with PES, 1397 patients with bare-metal stents) and from 2 postmarket registries (7492 patients with PES) were pooled separately.
Background: The TAXUS II trial was designed to evaluate the safety and efficacy of the commercialized slow-release (SR) and an investigation-only moderate-release (MR) polymer-based TAXUS paclitaxel-eluting stent compared with a bare-metal stent for the treatment of de novo coronary lesions.
Methods And Results: This prospective, randomized, double-blind, controlled trial enrolled 536 patients in 2 consecutive cohorts to compare TAXUS SR (n=131) and TAXUS MR (n=135) with an identical but uncoated bare-metal stent control (n=270). The present analysis reports final 5-year clinical outcomes of TAXUS II.
Aims: We report 2-year outcomes in a large unselected drug-eluting stent population (N=7,492) in the TAXUS Express2 ARRIVE post-market surveillance programme (101 U.S. sites).
View Article and Find Full Text PDFBackground: Although both sirolimus (CYPHER) and paclitaxel (TAXUS) drug-eluting stents have demonstrated efficacy and safety in clinical trials, human autopsy data have raised concerns about long-term healing and the potential for local inflammatory reactions.
Methods And Results: Overlapping stents (CYPHER drug-eluting stents, Bx SONIC bare metal stents, TAXUS drug-eluting stents, and Liberté bare metal stents) were implanted in noninjured coronary arteries of 58 domestic swine. Histopathological evaluation of proximal, overlapped, and distal stented segments was determined with emphasis on inflammation at 30, 90, and 180 days.
Objectives: We evaluated the relative contributions of drug-eluting stent-specific and background natural history-driven causes for adverse clinical events between 1 and 5 years, in the paclitaxel-eluting stent (PES) and bare-metal stent (BMS) cohorts of the TAXUS randomized clinical trial program.
Background: Prior studies have demonstrated that clinical events in the first year after BMS are predominantly stent-related but thereafter tend to be driven more by atherosclerotic activity outside the stented segment. It is not known whether the same is true for PES.
Objectives: The aim of this study was to assess the relative efficacy and safety of the second-generation TAXUS Liberté paclitaxel-eluting stent (PES) in patients with and without diabetes mellitus.
Background: Diabetic patients suffer from accelerated atherosclerosis and increased risk of restenosis after coronary interventions; however, prior data suggest that PES might blunt this effect, providing equal benefit in diabetic and nondiabetic patients.
Methods: A pooled analysis of all 4 TAXUS ATLAS studies was conducted that included 413 diabetic and 1,116 nondiabetic subjects treated with the TAXUS Liberté stent for de novo coronary lesions.
Objectives: The TAXUS ATLAS Small Vessel (SV) and Long Lesion (LL) multicenter studies compared the performance of the thin-strut (0.0038 inch) TAXUS Liberté 2.25-mm stent (Boston Scientific; Natick, Massachusetts) and the TAXUS Liberté 38-mm long stent (Boston Scientific; Natick, Massachusetts) with the earlier paclitaxel-eluting TAXUS Express (Boston Scientific) stent that has identical polymer, drug dosage, and release kinetics but different stent geometry and thicker struts (0.
View Article and Find Full Text PDFObjectives: This study was conducted to determine whether direct stenting with TAXUS Liberté is noninferior to stenting after pre-dilation.
Background: Direct stenting is performed in approximately 30% of patients, but data on clinical and angiographic outcomes with drug-eluting stents are limited.
Methods: The TAXUS ATLAS DIRECT STENT is a single-arm, multicenter study that enrolled patients with de novo coronary lesions visually estimated to be 10 to 28 mm in length in vessels 2.
We compared 1-year outcomes in patients treated with paclitaxel-eluting stents (PESs) or sirolimus-eluting stents (SESs) in "real-world" clinical practice. Clinical outcomes were evaluated in 1,558 consecutive, unselected, retrospectively collected patients treated with drug-eluting stents (DESs; PES = 816, SES = 742) at 19 United States centers. The primary end point was 1-year target vessel revascularization (TVR).
View Article and Find Full Text PDFLimited data are available on the relative effect of drug-eluting versus bare-metal stents on the requirement for subsequent coronary artery bypass grafting (CABG). The aim of this study was to evaluate the incidence and predictors of CABG after bare-metal and paclitaxel-eluting coronary stent implantation. A patient-level, pooled analysis was conducted of 2,736 patients from 3 double-blind, randomized trials comparing the slow-release paclitaxel-eluting Taxus stent with an otherwise identical bare-metal stent control in single de novo coronary lesions, with 5-year follow-up.
View Article and Find Full Text PDFPrevious observational studies have evaluated the utility of prolonged thienopyridine therapy in patients receiving drug-eluting stents, with conflicting results. A landmark analysis was therefore performed on the basis of the prospective, double-blind TAXUS-II SR, TAXUS-IV, and TAXUS-V trials. Of 2,736 randomized patients, 2,171 were event free at 1 year, of whom 964 (44.
View Article and Find Full Text PDFBackground: It is unclear how well the long-term safety and effectiveness of drug-eluting stents observed in tightly defined randomized controlled trials (RCT) translates to expanded use in routine practice.
Methods: The FDA-mandated TAXUS Express(2) ARRIVE 1 postmarket registry was designed to consecutively enroll patients receiving > or = 1 TAXUS stent in low-, medium-, and high-volume US sites (n = 50). All cardiac events plus an additional 20% sample of records were monitored and all endpoints were independently adjudicated.
Objective: The multicenter, single-arm CABERNET trial evaluated outcomes in high-surgical-risk patients with carotid artery stenosis treated with the NexStent plus FilterWire EX/EZ Emboli Protection System.
Background: For patients at high surgical risk, carotid artery stenting (CAS) offers a less invasive alternative to carotid endarterectomy (CEA).
Methods: The trial enrolled 454 high-surgical-risk patients with carotid stenosis by angiography > or = 50% for symptomatic patients and > or = 60% for asymptomatic patients.
Background: Treatment of saphenous vein graft (SVG) stenosis with percutaneous coronary intervention has a 15% to 20% incidence of major adverse cardiac events (MACE) within 30 days. Although MACE rates are reduced significantly by the use of embolic protection devices (EPDs), neither the level of baseline risk nor the benefit provided by EPDs has been well characterized.
Methods And Results: Data from 5 randomized controlled trials and 1 registry evaluating EPDs in SVG percutaneous coronary intervention (n=3958 patients) were pooled for analysis.
Background: Drug-eluting stents compared with bare metal stents (BMS) may increase late stent thrombosis (ST), although an accompanying increase in the rates of death and myocardial infarction (MI) has not been observed. We hypothesized that the prevention of restenosis-related adverse events by drug-eluting stents might offset some or all of the excess risk from ST.
Methods And Results: We analyzed a pooled patient-level database from 4 prospective, double-blind trials in which 3445 patients were randomized to paclitaxel-eluting stents or BMS.
Objectives: The goal of this research was to assess non-inferiority of the next-generation TAXUS Liberté stent (Boston Scientific Corp., Natick, Massachusetts) versus the TAXUS Express stent (Boston Scientific Corp.).
View Article and Find Full Text PDFCatheter Cardiovasc Interv
April 2007
New technologies introduced over the past three decades have transformed medical diagnosis and treatment, and significantly improved patient outcomes. These changes have been mediated by the introduction of new medical devices, particularly for the treatment of cardiovascular, orthopedic, and ophthalmic disorders. These devices, in turn, have created large markets and spawned a burgeoning medical device industry, including six Fortune 500 companies whose combined market capitalization now exceeds 400 billion dollars.
View Article and Find Full Text PDFIn 2005, the investigators described a "hybrid" cardiovascular interventional strategy combining percutaneous coronary intervention (PCI) for coronary artery disease (CAD) followed by valve surgery for patients with urgent complex CAD and valve disease to reduce morbidity and mortality. This hybrid approach has been extended prospectively in elderly, high-risk patients with aortic stenosis scheduled for elective minimally invasive aortic valve replacement (MI-AVR) who, on preoperative coronary angiography, were found to have moderate CAD amenable to PCI. In this prospective, observational series, 18 patients (mean age 76 years) underwent elective hybrid MI-AVR with PCI from May 2003 to February 2006.
View Article and Find Full Text PDFDiabetes mellitus (DM) increases the risk of clinically driven, repeat revascularization of the stented lesion in the first year after coronary stenting. The effect of DM on the risk of repeat revascularization of the stented lesion beyond 1 year, revascularization at other coronary sites, and clinical outcomes of cardiac death and myocardial infarction (MI) has not been reported. We pooled primary data from 4 multicenter trials of second-generation coronary stents that included 1,228 patients, 263 of whom (21%) had DM.
View Article and Find Full Text PDF