Purpose: Natural language processing (NLP) techniques have been adopted to reduce the curation costs of electronic health records. However, studies have questioned whether such techniques can be applied to data from previously unseen institutions. We investigated the performance of a common neural NLP algorithm on data from both known and heldout (ie, institutions whose data were withheld from the training set and only used for testing) hospitals.

View Article and Find Full Text PDF

Beginning with the advent of digital radiography systems in 1981, manufacturers of these systems provided indicators of detector exposure. These indicators were manufacturer-specific, and users in facilities with equipment from multiple manufacturers found it a challenge to monitor and manage variations in indicated exposure in routine clinical use. In 2008, a common definition of exposure index (EI) was realized in International Electrotechnical Commission (IEC) International Standard 62494-1 Ed.

View Article and Find Full Text PDF

Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP).

View Article and Find Full Text PDF

There is a clear need for established standards for medical physics residency training. The complexity of techniques in imaging, nuclear medicine, and radiation oncology continues to increase with each passing year. It is therefore imperative that training requirements and competencies are routinely reviewed and updated to reflect the changing environment in hospitals and clinics across the country.

View Article and Find Full Text PDF

Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data.

View Article and Find Full Text PDF

Reliable assessment of tumor growth in malignant glioma poses a common problem both clinically and when studying novel therapeutic agents. We aimed to evaluate two software-systems in their ability to estimate volume change of tumor and/or edema on magnetic resonance (MR) images of malignant gliomas. Twenty patients with malignant glioma were included from different sites.

View Article and Find Full Text PDF

The hypothesis that the human sodium-iodide symporter, NIS, can be used to detect NIS expression using standard radiological techniques was tested using adenoviral transduced NIS expression in human tumor xenografts grown in mice and in a naive dog prostate. Nonradioactive iodide was administered systemically to animals that 1-3 days previously had received a local injection of a replication-competent adenovirus expressing NIS under the control of the CMV promoter. The distribution of radiopacity was assessed in mouse tumors using micro-CT and a clinical X-ray machine and in the prostate of an anesthetized dog using a clinical spiral CT.

View Article and Find Full Text PDF

This study investigated the feasibility of imaging the migration and incorporation of magnetically-labeled sensitized splenocytes in an experimental 9L glioma brain tumor model. Splenocytes collected from tumor-bearing (sensitized splenocytes) or control (nonsensitized splenocytes) host rats were analyzed to determine the population of different cells, labeled with ferumoxides-protamine sulfate (FePro) and injected intravenously to recipient rats (N=4, for each group) bearing intracranial 9L tumors. Day 3 postinjection of splenocytes multiecho T2*-weighted and three-dimensional (3D) gradient echo MRI were obtained using a 7 Tesla MR system.

View Article and Find Full Text PDF

This paper presents a fast method for delineation of activated areas of the brain from functional magnetic resonance imaging (fMRI) time series data. The steps of the work accomplished are as follows. 1) It is shown that the detection performance evaluated by the area under the receiver operating characteristic curve is directly related to the signal-to-noise ratio (SNR) of the composite image generated in the detection process.

View Article and Find Full Text PDF