Publications by authors named "Donald Cutlip"

Article Synopsis
  • Patients who need oral anticoagulation and undergo coronary intervention can use a special stent (COBRA PzF) that may lower the need for long-term dual antiplatelet therapy (DAPT) while maintaining safety against blood clots.
  • In a study, 996 patients were randomized to receive either the COBRA PzF stent with a short 14-day DAPT or a regular stent with longer DAPT durations of 3 to 6 months.
  • Results showed that the COBRA stent did not significantly reduce bleeding compared to the control group and was not proven to maintain equivalent safety for thromboembolic events, indicating further investigation is needed.
View Article and Find Full Text PDF
Article Synopsis
  • * In the first trial (RCT-I), there were no significant differences in important health outcomes like cardiovascular mortality or stroke, while the second trial (RCT-II) showed a benefit in responder patients using shunts over a sham treatment.
  • * The atrial shunt treatment in responders led to fewer heart failure events and better health-related quality of life measured by KCCQ, but also had a higher rate of ischemic stroke and reduced worsening kidney dysfunction compared to sham treatment.
View Article and Find Full Text PDF
Article Synopsis
  • - The
  • REDUCE LAP-HF II
  • trial showed that the
  • Corvia Atrial Shunt
  • did not improve heart failure outcomes compared to a sham procedure, despite identifying "responders" who exhibited better exercise-related metrics after 12 months.
  • - This study aimed to assess the
  • long-term efficacy and safety
  • of the atrial shunt over 2 years, focusing on both overall patient outcomes and distinctions between responders and nonresponders.
  • - Results from
  • 621 patients
  • indicated no significant difference in major health events between the shunt and sham groups, but those with shunts experienced a higher rate of major adverse cardiac events and increased right ventricular volume; however, responders showed improved outcomes compared to the sham
View Article and Find Full Text PDF

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant.

View Article and Find Full Text PDF
Article Synopsis
  • The identification and management of patients at high bleeding risk (HBR) during transcatheter aortic valve implantation (TAVI) is critical, but inconsistent definitions complicate trials and clinical choices.
  • The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) involves global experts aiming to create a standard definition for HBR patients based on extensive research.
  • This initiative, led by the Cardiovascular European Research Center (CERC), seeks to enhance the safety and effectiveness of TAVI interventions and improve future clinical guidelines.
View Article and Find Full Text PDF

Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status.

Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status.

View Article and Find Full Text PDF

Aims: Obesity is causally related to the development of heart failure with preserved ejection fraction (HFpEF) but complicates the diagnosis and treatment of this disorder. We aimed to determine the relationship between severity of obesity and clinical, echocardiographic and haemodynamic parameters in a large cohort of patients with documented HFpEF.

Methods And Results: The REDUCE LAP-HF II trial randomized 626 patients with ejection fraction ≥40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mmHg to atrial shunt or sham procedure.

View Article and Find Full Text PDF

The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF).

Objectives: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden.

Methods: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days).

View Article and Find Full Text PDF

Background: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure.

Objectives: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH).

Methods: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc.

View Article and Find Full Text PDF

Objective: The Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial, a multicenter randomized controlled trial with 947 patients, concluded that there was no benefit of renal artery stenting (RAS) over medical therapy. However, patients with chronic kidney disease (CKD) were not analyzed separately in the CORAL trial. CKD is a risk factor for cardiovascular and renal morbidity.

View Article and Find Full Text PDF

Background: Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain.

Objectives: This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES).

View Article and Find Full Text PDF

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods.

View Article and Find Full Text PDF

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods.

View Article and Find Full Text PDF

Background: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD).

View Article and Find Full Text PDF

The clinical implications of hypertension in addition to a high prevalence of both uncontrolled blood pressure and medication nonadherence promote interest in developing device-based approaches to hypertension treatment. The expansion of device-based therapies and ongoing clinical trials underscores the need for consistency in trial design, conduct, and definitions of clinical study elements to permit trial comparability and data poolability. Standardizing methods of blood pressure assessment, effectiveness measures beyond blood pressure alone, and safety outcomes are paramount.

View Article and Find Full Text PDF

Background: Placement of an interatrial shunt device reduces pulmonary capillary wedge pressure during exercise in patients with heart failure and preserved or mildly reduced ejection fraction. We aimed to investigate whether an interatrial shunt can reduce heart failure events or improve health status in these patients.

Methods: In this randomised, international, blinded, sham-controlled trial performed at 89 health-care centres, we included patients (aged ≥40 years) with symptomatic heart failure, an ejection fraction of at least 40%, and pulmonary capillary wedge pressure during exercise of at least 25 mm Hg while exceeding right atrial pressure by at least 5 mm Hg.

View Article and Find Full Text PDF

Background/purpose: The COBRA Polyzene F™ NanoCoated Coronary Stent System (PzF coated stent) stent demonstrated favorable clinical outcomes at 9 months but late results have not been reported. We sought to assess the late safety and effectiveness of the PzF coated stent for treatment of de novo coronary artery lesions.

Methods: Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a non-randomized, prospective clinical trial and followed for 5 years.

View Article and Find Full Text PDF

Background: Guidelines recommend individualization of dual antiplatelet therapy (DAPT) duration. Whether to guide decisions based on bleeding risk, ischemic risk or a combination is not known.

Aims: To compare a bleeding prediction model, an ischemic prediction model, and the DAPT score in guiding DAPT duration.

View Article and Find Full Text PDF

Background: Ticagrelor is often administered to patients with acute coronary syndromes. However, when these patients require urgent or emergent cardiothoracic (CT) surgery the presence of ticagrelor significantly increases surgical bleeding. The goal of the current trial is to evaluate the effectiveness and safety of the DrugSorb-ATR hemoadsorption device for the intraoperative removal of ticagrelor to reduce postoperative bleeding in the above patient population.

View Article and Find Full Text PDF