Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant.
View Article and Find Full Text PDFImportance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status.
Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status.
Aims: Obesity is causally related to the development of heart failure with preserved ejection fraction (HFpEF) but complicates the diagnosis and treatment of this disorder. We aimed to determine the relationship between severity of obesity and clinical, echocardiographic and haemodynamic parameters in a large cohort of patients with documented HFpEF.
Methods And Results: The REDUCE LAP-HF II trial randomized 626 patients with ejection fraction ≥40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mmHg to atrial shunt or sham procedure.
The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials.
View Article and Find Full Text PDFBackground: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF).
Objectives: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden.
Methods: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days).
Background: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure.
Objectives: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH).
Methods: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc.
Objective: The Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial, a multicenter randomized controlled trial with 947 patients, concluded that there was no benefit of renal artery stenting (RAS) over medical therapy. However, patients with chronic kidney disease (CKD) were not analyzed separately in the CORAL trial. CKD is a risk factor for cardiovascular and renal morbidity.
View Article and Find Full Text PDFBackground: Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain.
Objectives: This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES).
The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods.
View Article and Find Full Text PDFThe Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods.
View Article and Find Full Text PDFBackground: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD).
View Article and Find Full Text PDFThe clinical implications of hypertension in addition to a high prevalence of both uncontrolled blood pressure and medication nonadherence promote interest in developing device-based approaches to hypertension treatment. The expansion of device-based therapies and ongoing clinical trials underscores the need for consistency in trial design, conduct, and definitions of clinical study elements to permit trial comparability and data poolability. Standardizing methods of blood pressure assessment, effectiveness measures beyond blood pressure alone, and safety outcomes are paramount.
View Article and Find Full Text PDFBackground: Placement of an interatrial shunt device reduces pulmonary capillary wedge pressure during exercise in patients with heart failure and preserved or mildly reduced ejection fraction. We aimed to investigate whether an interatrial shunt can reduce heart failure events or improve health status in these patients.
Methods: In this randomised, international, blinded, sham-controlled trial performed at 89 health-care centres, we included patients (aged ≥40 years) with symptomatic heart failure, an ejection fraction of at least 40%, and pulmonary capillary wedge pressure during exercise of at least 25 mm Hg while exceeding right atrial pressure by at least 5 mm Hg.
Cardiovasc Revasc Med
August 2022
Background/purpose: The COBRA Polyzene F™ NanoCoated Coronary Stent System (PzF coated stent) stent demonstrated favorable clinical outcomes at 9 months but late results have not been reported. We sought to assess the late safety and effectiveness of the PzF coated stent for treatment of de novo coronary artery lesions.
Methods: Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a non-randomized, prospective clinical trial and followed for 5 years.
Background: Guidelines recommend individualization of dual antiplatelet therapy (DAPT) duration. Whether to guide decisions based on bleeding risk, ischemic risk or a combination is not known.
Aims: To compare a bleeding prediction model, an ischemic prediction model, and the DAPT score in guiding DAPT duration.
Background: Ticagrelor is often administered to patients with acute coronary syndromes. However, when these patients require urgent or emergent cardiothoracic (CT) surgery the presence of ticagrelor significantly increases surgical bleeding. The goal of the current trial is to evaluate the effectiveness and safety of the DrugSorb-ATR hemoadsorption device for the intraoperative removal of ticagrelor to reduce postoperative bleeding in the above patient population.
View Article and Find Full Text PDF