Publications by authors named "Donald Benza"

Measuring chemical concentrations at the surface of implanted medical devices is important for elucidating the local biochemical environment, especially during implant infection. Although chemical indicator dyes enable chemical measurements in vitro, they are usually ineffective when measuring through tissue because the background obscures the dye signal and scattering dramatically reduces the spatial resolution. X-ray excited luminescent chemical imaging (XELCI) is a recent imaging modality which overcomes these limitations using a focused X-ray beam to excite a small spot of red light on scintillator-coated medical implants with well-defined location (because X-rays are minimally scattered) and low background.

View Article and Find Full Text PDF

The optical and chemical properties of gold and silver nanoparticles make them useful for many applications, including surface enhanced spectroscopy-based biosensors, photostable colorants, enhanced photovoltaics, and nanoscale optical elements. We report a simple technique to generate patterns of gold and silver nanoparticles with controlled shape and shape-dependent optical properties using metal stamps to impress them onto a glass substrate or flexible polymers. The pressure flattens the nanoparticles, converting initially spherical nanoparticles into discs with reduced height and increased diameter.

View Article and Find Full Text PDF

We describe a method to measure micron to millimeter displacement through tissue using an upconversion spectral ruler. Measuring stiffness (displacement under load) in muscles, bones, ligaments, and tendons is important for studying and monitoring healing of injuries. Optical displacement measurements are useful because they are sensitive and noninvasive.

View Article and Find Full Text PDF

We describe a pH-indicating material that can be directly implanted or coated on orthopedic implant surfaces to provide high-spatial-resolution pH mapping through tissue by X-ray excited luminescence chemical imaging (XELCI). This is especially useful for detecting local pH changes during treatment of implant-associated infections. The material has two layers: an X-ray scintillator layer with GdOS:Eu in epoxy, which emits 620 and 700 nm light when irradiated with X-rays, and a pH indicator dye layer, which absorbs some of the 620 nm light in a pH-dependent fashion.

View Article and Find Full Text PDF

A luminescent spectral ruler was developed to measure micrometer to millimeter displacements through tissue. The spectral ruler has two components: a luminescent encoder patterned with alternating stripes of two spectrally distinct luminescent materials and an analyzer mask with periodic transparent windows the same width as the encoder stripes. The analyzer mask is placed over the encoder and held so that only one type of luminescent stripe is visible through the window; sliding the analyzer over the encoder modulates the luminescence spectrum acquired through the analyzer windows, enabling detection of small displacements without imaging.

View Article and Find Full Text PDF

Implanted medical device-associated infections are a leading cause of fixation failure, and early diagnosis is the key to successful treatment. During infection, acidosis near the implant plays a role in antibiotic resistance and low pH is a potential infection indicator. Herein, we describe a pH sensor which attaches to the implants to noninvasively image local pH with high spatial resolution.

View Article and Find Full Text PDF

X-ray excited luminescent chemical imaging (XELCI) uses a combination of X-ray excitation to provide high resolution and optical detection to provide chemical sensing. A key application is to detect and study implant-associated infection. The implant is coated with a layer of X-ray scintillators which generate visible near infrared light when irradiated with an X-ray beam.

View Article and Find Full Text PDF

Current orthopaedic clinical methods do not provide an objective measure of fracture healing or weight bearing for lower extremity fractures. The following report describes a novel approach involving in-situ strain sensors to objectively measure fracture healing. The sensor uses a cantilevered indicator pin that responds to plate bending and an internal scale to demonstrate changes in the pin position on plain film radiographs.

View Article and Find Full Text PDF

We describe a simple technique to alter the shape of silver nanoparticles (AgNPs) by rolling a glass tube over them to mechanically compress them. The resulting shape change in turn induces a red-shift in the localized surface plasmon resonance (LSPR) scattering spectrum and exposes new surface area. The flattened particles were characterized by optical and electron microscopy, single nanoparticle scattering spectroscopy, and surface enhanced Raman spectroscopy (SERS).

View Article and Find Full Text PDF