Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius® 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
November 2013
Although much literature has been devoted to portal dosimetry with the Varian amorphous silicon (aSi) portal imager, the majority of the described methods are not routinely adopted because implementation procedures are cumbersome and not within easy reach of most radiotherapy centers. To make improved portal dosimetry solutions more generally available, we have investigated the possibility of converting optimized configurations into ready-to-use standardized datasets. Firstly, for all commonly used photon energies (6, 10, 15, 18, and 20 MV), basic beam data acquired on 20 aSi panels were used to assess the interpanel reproducibility.
View Article and Find Full Text PDFPurpose: With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution.
Methods: The program was developed and tested out for a Millennium120 MLC on iX Clinacs and a HighDefinition MLC on a Novalis TX, using a variety of measurement equipment including Gafchromic film, 2D ion chamber arrays (Seven29 and StarCheck, PTW, Freiburg, Germany) with inclinometer and Octavius phantom, the Delta4 systam (ScandiDos, Uppsala, Sweden) and the portal imager (EPID).
Introduction: EORTC trial 22991 was designed to evaluate the addition of concomitant and adjuvant short-term hormonal treatments to curative radiotherapy in terms of disease-free survival for patients with intermediate risk localized prostate cancer. In order to assess the compliance to the 3D conformal radiotherapy protocol guidelines, all participating centres were requested to participate in a dummy run procedure. An individual case review was performed for the largest recruiting centres as well.
View Article and Find Full Text PDFPurpose: This work describes the clinical validation of an automatic segmentation algorithm in CT-based radiotherapy planning for prostate cancer patients.
Material And Methods: The validated auto-segmentation algorithm (Smart Segmentation, version 1.0.
For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements.
View Article and Find Full Text PDFBackground And Purpose: To reduce the dose to the heart during left breast irradiation, a moderate deep breath hold technique (MDIBH) was introduced. Originally, verification of the MDIBH was performed with portal images acquired in movie loop during the treatment delivery. However, this verification method is not compatible with the use of dynamic MLC compensation, recently introduced because of its often superior dose distribution.
View Article and Find Full Text PDFThe analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source.
View Article and Find Full Text PDFBackground And Purpose: The aim of this work is to set-up mailed entrance in vivo dosimetry by means of thermoluminescence dosimeters (TLDs) in the form of LiF powder in order to assess the overall accuracy of patient treatment delivery by comparing the doses delivered to patients with the doses calculated by the treatment planning system (TPS) in different institutions.
Patients And Methods: Two millimeter thick copper (for 6 MV photon beams) and 1.3 mm thick aluminium (for (60)Co gamma beams) build-up caps are developed.
Background And Purpose: In parallel with the increased use of intensity modulated radiation treatment (IMRT) fields in radiation therapy, flat panel amorphous silicon (aSi) detectors are becoming the standard for online portal imaging at the linear accelerator. In order to minimise the workload related to the quality assurance of the IMRT fields, we have explored the possibility of using a commercially available aSi portal imager for absolute dosimetric verification of the delivery of dynamic IMRT fields.
Patients And Methods: We investigated the basic dosimetric characteristics of an aSi portal imager (aS500, Varian Medical Systems), using an acquisition mode especially developed for portal dose (PD) integration during delivery of a-static or dynamic-radiation field.
Background And Purpose: An increasing number of radiotherapy centres is now aiming for clinical implementation of intensity modulated radiotherapy (IMRT), but--in contrast to conventional treatment--no national or international guidelines for commissioning of the treatment planning system (TPS) and acceptance tests of treatment equipment have yet been developed. This paper bundles the experience of five radiotherapy departments that have introduced IMRT into their clinical routine.
Methods And Materials: The five radiotherapy departments are using similar configurations since they adopted the commercially available Varian solution for IMRT, regarding treatment planning as well as treatment delivery.
Background And Purpose: This study presents a technical description of the solid multipurpose phantom (MPP) 'OPERA' (operational phantom for external radiotherapy audit) for mailed dosimetry checks of photon beams in reference and non-reference conditions. The aim is to test the functionality of this phantom by comparing the results provided by the local treatment planning system (TPS) with the measurements by film and thermoluminescence dosimeters (TLDs) in a number of clinical conditions.
Material And Methods: The polystyrene MPP is constructed to check the following five irradiation conditions: square fields, asymmetrical fields, wedged beams, oblique incidence and influence of inhomogeneities in the field.
Background And Purpose: Although intensity modulated radiotherapy (IMRT) is a step forward in comparison to conventional, static beam delivery, quality assurance is more complex and labour intensive, demanding detailed two-dimensional dosimetric verification. Regardless of the technique used for measuring the dose distribution, what is essential to the implementation of routine verification of IMRT fields is the efficient and accurate comparison of the measured versus desired dose distribution. In order to achieve a fast, yet accurate quantitative measure of the correspondence between measured and calculated dose, the theoretical concept of the gamma evaluation method presented by Low et al.
View Article and Find Full Text PDFBackground And Purpose: Quality assurance (QA) in intensity modulated treatments is a complex and time-consuming process. In spite of intensive quality control procedures some types of errors still can go undetected through the course of a treatment. This study aims to develop an objective QA filter for fast, automatic detection of errors, based on the creation of a global platform monitoring treatment parameters by comparison with existing local standards.
View Article and Find Full Text PDF