Background: Sagittal spinopelvic translation (SSPT) is the horizontal distance from the hip center to the C7 plumb line (C7PL). SSPT is an important variable showing the overall patient balance in different functional positions which could affect the rate of hip instability. This study investigates the SSPT modification in patients who underwent total hip arthroplasty (THA).
View Article and Find Full Text PDFObjectives: Previous MRI studies showed that involvement of connective tissue in muscle injuries may prolong recovery times. The relevance of ultrasound assessment of connective tissue involvement as a prognostic factor is unknown. The aim was to test the hypothesis that ultrasound-detected connective tissue involvement in acute muscle injuries are related to longer recovery times.
View Article and Find Full Text PDFBackground: This study assessed the correlation among the patients' perception of the leg length discrepancy (LLD) after total hip arthroplasty (THA) and the anatomical and functional leg length, pelvic and knee alignments, and foot height.
Methods: Patients without significant spinal pathology or previous spine or lower extremity surgery who underwent primary THA (101 patients) were evaluated using EOS images obtained in standing position. All 3-dimensional measures were evaluated and compared for the repeatability and reproducibility and correlation with patients' perception of leg length.
Background: This study used EOS imaging of primary total hip arthroplasty (THA) patients, with and without predating spinal fusion, to investigate (1) the impact of spinal fusion on acetabular implant anteversion and inclination, and (2) whether more extensive spinal fusion (fusion starting above the thoracolumbar junction or extension of fusion to the sacrum) affects acetabular implant orientation differently than lumbar only spinal fusion.
Methods: Ninety-three patients had spinal fusion (case group), and 150 patients were without spinal fusion (controls). None of the patients experienced dislocation.
Background: Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement.
View Article and Find Full Text PDFLumbar stenosis is frequently observed and treated by spine surgeons. The extent of neurological decompression and the potential spinal fixation are the basic concerns when surgery is planned. But this segmented approach to the problem is sometimes insufficient due to the complex functional situations induced by a sagittal imbalance of the patient and the combination of pathologies known as hip-spine or knee-spine syndromes.
View Article and Find Full Text PDFMore total hip arthroplasty (THA) is performed worldwide and especially in younger and more active patients compared to earlier decades. One of the focuses of THA research in the future will be on optimizing the radiological follow-up of these patients using 2D and 3D measurements of implants position while reducing the radiation dose delivered. Low-dose EOS(®) imaging is an innovative slot-scanning radiograph system providing valuable information in patient functional positions (standing, sitting and even squatting positions).
View Article and Find Full Text PDFPurpose: Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images of the patient in the standing position possible. These two-dimensional (2D) images are equivalent to standard plane X-rays.
View Article and Find Full Text PDFObjectives: To calculate and compare the doses of ionizing radiation delivered to the organs by computed tomography (CT) and stereoradiography (SR) during measurements of lower limb torsion and anteversion.
Materials And Methods: A Rando anthropomorphic phantom (Alderson RANDO phantom, Alderson Research Laboratories Inc., Stanford, Conn) was used for the dose measurements.
Objective: Knee coronal alignment is routinely assessed on a full-length radiograph of the lower limbs. However, poor positioning of the knee during the procedure affects the accuracy of this kind of measurement, particularly in cases combining knee rotation and flexion. The purpose of this study was to assess the value of a three-dimensional assessment of the hip-knee-ankle (HKA) angle based on a biplanar radiographic system.
View Article and Find Full Text PDF