Publications by authors named "Dominik Peter"

Aim was to evaluate the influence of different quantum iterative reconstruction (QIR) levels on the image quality of femoral photon-counting CT angiographies (PCD-CTA).Ultra-high resolution PCD-CTA were obtained from both extremities of five extracorporeally-perfused cadavers using constant tube voltage and maximum radiation dose (71.2 ± 11.

View Article and Find Full Text PDF

This single-center study investigated the safety and efficacy of transarterial embolization of type II endoleaks for expanding aneurysm sacs following endovascular aortic repair (EVAR).36 patients (33 men, 75.9±6.

View Article and Find Full Text PDF

Background And Aims: The aim of this study was to investigate the imaging performance and quality differences of PCD-CT in standard resolution mode (SR) versus ultra-high resolution mode (UHR) in the lower extremity runoff of dose-matched CTAs in a human cadaveric model.

Methods: Extracorporeal perfusion of the upper leg was established in one fresh-frozen human cadaver via inguinal and popliteal accesses using a peristaltic pump. Seven peripheral stents were deployed in the SFA.

View Article and Find Full Text PDF
Article Synopsis
  • The study assesses the effectiveness and safety of a specific procedure (percutaneous rotational thrombectomy) used to treat acute blockages in the superior mesenteric artery, which can lead to bowel tissue damage.
  • In a retrospective analysis of 15 cases, technical success was achieved in 93.3% of instances, demonstrating significant improvement in blood flow after the treatment.
  • Despite its success, the procedure poses risks, including a 20% major complication rate and a concerning 30-day mortality rate of 40%, emphasizing the procedure's complexity and risks involved.
View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the usability of a recently developed extracorporeally-perfused cadaver model for training the angiographic management of acute arterial diseases and periprocedural complications that may occur during endovascular therapy of the lower extremity arterial runoff.

Materials And Methods: Continuous extracorporeal perfusion was established in three fresh-frozen body donors via inguinal and infragenicular access. Using digital subtraction angiography for guidance, both arterial embolization (e.

View Article and Find Full Text PDF

Background: With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies.

Methods: After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode.

View Article and Find Full Text PDF

With endovascular therapy becoming the first-line treatment for symptomatic chronic mesenteric ischemia, acute pancreatitis within the context of abdominal ischemia-reperfusion injury may be seen more often in cross-sectional imaging following this kind of interventions and should therefore be kept in mind by the reading physician.

View Article and Find Full Text PDF

Background And Aims: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff.

Methods: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty.

View Article and Find Full Text PDF

Objectives: We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS).

Methods: The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers.

View Article and Find Full Text PDF

Objectives: Detailed visualization of the arterial runoff is mandatory for the assessment of peripheral arterial occlusive disease. This study aims to compare the performance of a first-generation photon-counting detector computed tomography (PCD-CT) to a third-generation energy-integrating detector CT (EID-CT).

Materials And Methods: Computed tomography angiographies of 8 upper leg arterial runoffs were performed on human cadaveric models with continuous extracorporeal perfusion.

View Article and Find Full Text PDF

Developing new carbon dioxide (CO) fixing enzymes is a prerequisite to create new biocatalysts for diverse applications in chemistry, biotechnology and synthetic biology. Here we used bioinformatics to identify a "sleeping carboxylase function" in the superfamily of medium-chain dehydrogenases/reductases (MDR), i.e.

View Article and Find Full Text PDF

Cells must cope with toxic or reactive intermediates formed during metabolism. One coping strategy is to sequester reactions that produce such intermediates within specialized compartments or tunnels connecting different active sites. Here, we show that propionyl-CoA synthase (PCS), an ∼ 400-kDa homodimer, three-domain fusion protein and the key enzyme of the 3-hydroxypropionate bi-cycle for CO fixation, sequesters its reactive intermediate acrylyl-CoA.

View Article and Find Full Text PDF

A variety of biogas residues (BGRs) have been used as organic fertilizer in agriculture. The use of these residues affects the storage of soil organic matter (SOM). In most cases, SOM changes can only be determined in long-term observations.

View Article and Find Full Text PDF

Coenzyme A (CoA) is a ubiquitous cofactor present in every known organism. The thioesters of CoA are core intermediates in many metabolic processes, such as the citric acid cycle, fatty acid biosynthesis and secondary metabolism, including polyketide biosynthesis. Synthesis of CoA-thioesters is vital for the study of CoA-dependent enzymes and pathways, but also as standards for metabolomics studies.

View Article and Find Full Text PDF

Carboxylating enoyl-thioester reductases (ECRs) are a recently discovered class of enzymes. They catalyze the highly efficient addition of CO2 to the double bond of α,β-unsaturated CoA-thioesters and serve two biological functions. In primary metabolism of many bacteria they produce ethylmalonyl-CoA during assimilation of the central metabolite acetyl-CoA.

View Article and Find Full Text PDF

The pyridine nucleotides NADH and NADPH (NAD(P)H) are ubiquitous redox coenzymes that are present in all living cells. Although about 16% of all characterized enzymes use pyridine nucleotides as hydride donors or acceptors during catalysis, a detailed understanding of how the hydride is transferred between NAD(P)H and the corresponding substrate is lacking for many enzymes. Here we present evidence for a new mechanism that operates during enzymatic hydride transfers using crotonyl-CoA carboxylase/reductase (Ccr) as a case study.

View Article and Find Full Text PDF

Evidence exists that cAMP stabilizes the endothelial barrier, in part via activation of the small GTPase Rac1. However, despite the high medical relevance of this signaling pathway, the mechanistic effects on intercellular contacts on the ultrastructural level are largely unknown. In microvascular endothelial cell monolayers, in which increased cAMP strengthened barrier properties, similar to intact microvessels in vivo, both forskolin and rolipram (F/R) to increase cAMP and 8-(4-chlorophenylthio)-2'-O-methyladenosine-3',5'-cyclic monophosphorothioate (O-Me-cAMP) to stimulate exchange protein directly activated by cAMP/Ras proximate-1 (EPac/Rap 1) signaling enhanced transendothelial electrical resistance and induced activation of Rac1.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session0je2660mdi3atr1dira1g44hht7om1co): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once