Publications by authors named "Dominic Foley"

The pandemic readiness toolbox needs to be extended, targeting different biomolecules, using orthogonal experimental set-ups. Here, we build on our Cov-MS effort using LC-MS, adding SISCAPA technology to enrich proteotypic peptides of the SARS-CoV-2 nucleocapsid (N) protein from trypsin-digested patient samples. The CovMS assay is compatible with most matrices including nasopharyngeal swabs, saliva, and plasma and has increased sensitivity into the attomole range, a 1000-fold improvement compared to direct detection in a matrix.

View Article and Find Full Text PDF
Article Synopsis
  • The UK's Department of Health initiated the Moonshot programme in 2020 to enhance SARS-CoV-2 testing, exploring various diagnostic technologies, including mass spectrometry.
  • A targeted protein assay was developed using liquid chromatography tandem mass spectrometry (LC-MS/MS) to detect specific peptides from the virus in nasopharyngeal swabs, and its effectiveness was compared with the standard RT-qPCR method.
  • The LC-MS/MS method showed high sensitivity (92.4%) and specificity (97.4%) for detecting SARS-CoV-2, validating its potential for faster clinical application and setting a model for future diagnostic innovations.
View Article and Find Full Text PDF

Reliable, robust, large-scale molecular testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for monitoring the ongoing coronavirus disease 2019 (COVID-19) pandemic. We have developed a scalable analytical approach to detect viral proteins based on peptide immuno-affinity enrichment combined with liquid chromatography-mass spectrometry (LC-MS). This is a multiplexed strategy, based on targeted proteomics analysis and read-out by LC-MS, capable of precisely quantifying and confirming the presence of SARS-CoV-2 in phosphate-buffered saline (PBS) swab media from combined throat/nasopharynx/saliva samples.

View Article and Find Full Text PDF

Analytical scale active flow technology first generation silica monolithic columns kitted out in curtain flow mode of operation were studied for the first time. A series of tests were undertaken assessing the column efficiency, peak asymmetry and detection sensitivity. Two curtain flow columns were tested, one with a fixed outlet ratio of 10% through the central exit port, the other with 30%.

View Article and Find Full Text PDF

Active flow technology (AFT) columns are designed to minimise inefficient flow processes associated with the column wall and radial heterogeneity of the stationary phase bed. This study is the first to investigate AFT on an analytical scale 4.6mm internal diameter first-generation silica monolith.

View Article and Find Full Text PDF