This paper characterizes the correlation of simultaneous measurements with different fast-ion H-alpha (FIDA) spectroscopy sightlines on Wendelstein 7-X. Using a collisionless guiding-center code, it is shown that, for two investigated volumes in the bulk of the plasma, some regions of phase space are correlated and the magnetic configuration has little influence on this correlation. For the sightlines of the FIDA system, the correlation between these is explained well by the magnetic configuration.

View Article and Find Full Text PDF

This paper reports about a novel approach to the absolute intensity calibration of an electron cyclotron emission (ECE) spectroscopy system. Typically, an ECE radiometer consists of tens of separated frequency channels corresponding to different plasma locations. An absolute calibration of the overall diagnostic including near plasma optics and transmission line is achieved with blackbody sources at LN temperature and room temperature via a hot/cold calibration mirror unit.