Publications by authors named "Dmitriy D Karnaushenko"

Article Synopsis
  • Developing adaptive materials that can change shape and interact with their environment is a complex challenge in design.
  • This research introduces new strain-engineered materials that use micro-origami technology to create shapes that can change in response to stimuli like chemicals and electricity.
  • Two examples of their application include a foldable supercapacitor that boosts energy efficiency and a dynamic bio-adaptive device that could lead to advanced smart implants in healthcare.
View Article and Find Full Text PDF

Zn batteries show promise for microscale applications due to their compatibility with air fabrication but face challenges like dendrite growth and chemical corrosion, especially at the microscale. Despite previous attempts in electrolyte engineering, achieving successful patterning of electrolyte microscale devices has remained challenging. Here, successful patterning using photolithography is enabled by incorporating caffeine into a UV-crosslinked polyacrylamide hydrogel electrolyte.

View Article and Find Full Text PDF

To maintain the downscaling of microelectronic devices with footprints less than one square millimeter, next-generation microbatteries should occupy the same area and deliver adequate energy for running a new generation of multi-functional microautonomous systems. However, the current microbattery technology fails in accomplishing this task because the micrometer-sized electrodes are not compatible with on-chip integration protocols and technologies. To tackle this critical challenge, an on-chip Swiss-roll microelectrode architecture is employed that exploits the self-assembly of thin films into ultra-compact device architectures.

View Article and Find Full Text PDF

Magnetic sensors are widely used in our daily life for assessing the position and orientation of objects. Recently, the magnetic sensing modality has been introduced to electronic skins (e-skins), enabling remote perception of moving objects. However, the integration density of magnetic sensors is limited and the vector properties of the magnetic field cannot be fully explored since the sensors can only perceive field components in one or two dimensions.

View Article and Find Full Text PDF

Existing electronically integrated catheters rely on the manual assembly of separate components to integrate sensing and actuation capabilities. This strongly impedes their miniaturization and further integration. Here, we report an electronically integrated self-assembled microcatheter.

View Article and Find Full Text PDF

The functionality of a ferroic device is intimately coupled to the configuration of domains, domain boundaries, and the possibility for tailoring them. Exemplified with a ferromagnetic system, we present a novel approach which allows the creation of new, metastable multidomain patterns with tailored wall configurations through a self-assembled geometrical transformation. By preparing a magnetic layer system on a polymeric platform including swelling layer, a repeated self-assembled rolling into a multiwinding tubular structure and unrolling of the functional membrane is obtained.

View Article and Find Full Text PDF

Oscillations at several hertz are a key feature of dynamic behavior of various biological entities, such as the pulsating heart, firing neurons, or the sperm-beating flagellum. Inspired by nature’s fundamental self-oscillations, we use electroactive polymer microactuators and three-dimensional microswitches to create a synthetic electromechanical parametric relaxation oscillator (EMPRO) that relies on the shape change of micropatterned polypyrrole and generates a rhythmic motion at biologically relevant stroke frequencies of up to ~95 Hz. We incorporate an Ag-Mg electrochemical battery into the EMPRO for autonomous operation in a nontoxic environment.

View Article and Find Full Text PDF

Today's smallest energy storage devices for in-vivo applications are larger than 3 mm and lack the ability to continuously drive the complex functions of smart dust electronic and microrobotic systems. Here, we create a tubular biosupercapacitor occupying a mere volume of 1/1000 mm (=1 nanoliter), yet delivering up to 1.6 V in blood.

View Article and Find Full Text PDF

Many modern electronic applications rely on functional units arranged in an active-matrix integrated on a single chip. The active-matrix allows numerous identical device pixels to be addressed within a single system. However, next-generation electronics requires heterogeneous integration of dissimilar devices, where sensors, actuators, and display pixels sense and interact with the local environment.

View Article and Find Full Text PDF

Imperceptible electronics will make next-generation healthcare and biomedical systems thinner, lighter, and more flexible. While other components are thoroughly investigated, imperceptible energy storage devices lag behind because the decrease of thickness impairs the area-specific energy density. Imperceptible supercapacitors with high area-specific capacitance based on reduced graphene oxide/polyaniline (RGO/PANI) composite electrodes and polyvinyl alcohol (PVA)/H SO gel electrolyte are reported.

View Article and Find Full Text PDF
Article Synopsis
  • Analytical platforms using impedance spectroscopy offer a non-invasive way to study single cells and their environment, vital for understanding disease-related functions.
  • The newly developed "sensor-in-a-tube" combines rolled-up platinum microelectrodes to analyze human monocytes and their extracellular medium activated by liposaccharides (LPS).
  • This innovative sensor successfully detects the relationship between cell activation states and the electrical properties of their surroundings without needing any labeling or surface modifications, making it a valuable tool for diagnosing immune-related diseases.
View Article and Find Full Text PDF

Owing to their high safety and reversibility, aqueous microbatteries using zinc anodes and an acid electrolyte have emerged as promising candidates for wearable electronics. However, a critical limitation that prevents implementing zinc chemistry at the microscale lies in its spontaneous corrosion in an acidic electrolyte that causes a capacity loss of 40% after a ten-hour rest. Widespread anti-corrosion techniques, such as polymer coating, often retard the kinetics of zinc plating/stripping and lack spatial control at the microscale.

View Article and Find Full Text PDF

Embryo transfer (ET) is a decisive step in the in vitro fertilization process. In most cases, the embryo is transferred to the uterus after several days of in vitro culture. Although studies have identified the beneficial effects of ET on proper embryo development in the earlier stages, this strategy is compromised by the necessity to transfer early embryos (zygotes) back to the fallopian tube instead of the uterus, which requires a more invasive, laparoscopic procedure, termed zygote intrafallopian transfer (ZIFT).

View Article and Find Full Text PDF

Miniaturization of batteries lags behind the success of modern electronic devices. Neither the device volume nor the energy density of microbatteries meets the requirement of microscale electronic devices. The main limitation for pushing the energy density of microbatteries arises from the low mass loading of active materials.

View Article and Find Full Text PDF

Mechanical strain formed at the interfaces of thin films has been widely applied to self-assemble 3D microarchitectures. Among them, rolled-up microtubes possess a unique 3D geometry beneficial for working as photonic, electromagnetic, energy storage, and sensing devices. However, the yield and quality of microtubular architectures are often limited by the wet-release of lithographically patterned stacks of thin-film structures.

View Article and Find Full Text PDF

Novel robotic, bioelectronic, and diagnostic systems require a variety of compact and high-performance sensors. Among them, compact three-dimensional (3D) vector angular encoders are required to determine spatial position and orientation in a 3D environment. However, fabrication of 3D vector sensors is a challenging task associated with time-consuming and expensive, sequential processing needed for the orientation of individual sensor elements in 3D space.

View Article and Find Full Text PDF

Self-assembly of two-dimensional patterned nanomembranes into three-dimensional micro-architectures has been considered a powerful approach for parallel and scalable manufacturing of the next generation of micro-electronic devices. However, the formation pathway towards the final geometry into which two-dimensional nanomembranes can transform depends on many available degrees of freedom and is plagued by structural inaccuracies. Especially for high-aspect-ratio nanomembranes, the potential energy landscape gives way to a manifold of complex pathways towards misassembly.

View Article and Find Full Text PDF

Inspired by origami art, we demonstrate a tubular microsupercapacitor (TMSC) by self-assembling two-dimensional (2D) films into a "swiss roll" structure with greatly reduced footprint area. A polymeric framework consisting of swelling hydrogel and polyimide layers ensures excellent ion transport between poly(3,4-ethylenedioxythiophene) (PEDOT)-based electrodes and provides efficient self-protection of the TMSC against external compression up to about 30 MPa. Such TMSCs exhibit an areal capacitance of 82.

View Article and Find Full Text PDF

Electronic skins equipped with artificial receptors are able to extend our perception beyond the modalities that have naturally evolved. These synthetic receptors offer complimentary information on our surroundings and endow us with novel means of manipulating physical or even virtual objects. We realize highly compliant magnetosensitive skins with directional perception that enable magnetic cognition, body position tracking, and touchless object manipulation.

View Article and Find Full Text PDF

Information tagging and processing are vital in information-intensive applications, e.g., telecommunication and high-throughput drug screening.

View Article and Find Full Text PDF

We report an ultrasensitive label-free DNA biosensor with fully on-chip integrated rolled-up nanomembrane electrodes. The hybridization of complementary DNA strands (avian influenza virus subtype H1N1) is selectively detected down to attomolar concentrations, an unprecedented level for miniaturized sensors without amplification. Impedimetric DNA detection with such a rolled-up biosensor shows 4 orders of magnitude sensitivity improvement over its planar counterpart.

View Article and Find Full Text PDF

A novel method relying on strain engineering to realize arrays of on-chip-integrated giant magneto-impedance (GMI) sensors equipped with pick-up coils is put forth. The geometrical transformation of an initially planar layout into a tubular 3D architecture stabilizes favorable azimuthal magnetic domain patterns. This work creates a solid foundation for further development of CMOS compatible GMI sensorics for magnetoencephalography.

View Article and Find Full Text PDF

Smart biomimetics, a unique class of devices combining the mechanical adaptivity of soft actuators with the imperceptibility of microelectronics, is introduced. Due to their inherent ability to self-assemble, biomimetic microelectronics can firmly yet gently attach to an inorganic or biological tissue enabling enclosure of, for example, nervous fibers, or guide the growth of neuronal cells during regeneration.

View Article and Find Full Text PDF

High-performance giant magnetoresistive (GMR) sensorics are realized, which are printed at predefined locations on flexible circuitry. Remarkably, the printed magnetosensors remain fully operational over the complete consumer temperature range and reveal a giant magnetoresistance up to 37% and a sensitivity of 0.93 T(-1) at 130 mT.

View Article and Find Full Text PDF

Asymmetry of magnetic objects in a fluid under an oscillating magnetic field leads to a wealth of nonequilibrium dynamics phenomena including a novel ratchet effect without an asymmetric substrate. These nonlinear dynamics are explained in the framework of the Stokes' model by a drag coefficient, which depends on the direction of motion. This approach is general and is independent of the physical mechanism responsible for this directional dependence of the drag coefficient as well as the size of the object.

View Article and Find Full Text PDF