Frequency-degenerate pulsed type-I parametric downconversion is a widely used source of squeezed light for numerous quantum optical applications. However, this source is typically spectrally multimode, and the generated squeezing is distributed between many spectral modes with a limited degree of squeezing per mode. We show that in a nonlinear crystal, where the condition of complete group velocity matching (GVM) for the pump and the signal is satisfied, the number of generated modes may be as low as two or three modes.
View Article and Find Full Text PDFA simple method for designing spatiotemporal coherency vortices (STCVs) and spatiotemporal dislocation curves (STDCs) is introduced by means of coherent-mode representation and Fourier transforms. A partially coherent pulsed beam is represented by an incoherent superposition of a Gaussian and a Hermite-Gaussian pulsed beam with different waist positions. It well demonstrates that there exist STCVs and STDCs in the space-time plane.
View Article and Find Full Text PDFA time lens allows one to stretch or compress optical waveforms in time, similar to the conventional lens in space. However, a single-time-lens imaging system always imparts a residual temporal chirp on the image, which may be detrimental for quantum networks, where the temporal image interacts with other fields. We show that a two-time-lens imaging system satisfying the telescopic condition, a time telescope, is necessary and sufficient for creating a chirpless image.
View Article and Find Full Text PDFTemporal ghost imaging is based on the temporal correlations of two optical beams and aims at forming a temporal image of a temporal object with a resolution, fundamentally limited by the photodetector resolution time and reaching 55 ps in a recent experiment. For further improvement of the temporal resolution, it is suggested to form a spatial ghost image of a temporal object relying on strong temporal-spatial correlations of two optical beams. Such correlations are known to exist between two entangled beams generated in type-I parametric downconversion.
View Article and Find Full Text PDFA novel method to achieve the coherence control of spatiotemporal coherency vortices of spatially and temporally partially coherent pulsed vortex (STPCPV) beams is proposed. The influence of spatial and temporal coherence of the source on the phase distributions and the positions of spatiotemporal coherency vortices of the STPCPV beams propagating through fused silica is investigated in detail, for the first time to our knowledge. It is found that the coherence width and the coherence time of the incident beam can be regarded as a perfect tool for controlling the phase distribution and position of a spatiotemporal coherency vortex.
View Article and Find Full Text PDFWe present a single-pass source of broadband multimode squeezed light with potential application in quantum information and quantum metrology. The source is based on a type I parametric down-conversion (PDC) process inside a bulk nonlinear crystal in a non-collinear configuration. The generated squeezed light exhibits a spatio-temporal multimode behavior that is probed using a homodyne measurement with a local oscillator shaped both spatially and temporally.
View Article and Find Full Text PDFWe introduce a new distance-based measure for the nonclassicality of the states of a bosonic field, which outperforms the existing such measures in several ways. We define for that purpose the operator ordering sensitivity of the state which evaluates the sensitivity to operator ordering of the Renyi entropy of its quasiprobabilities and which measures the oscillations in its Wigner function. Through a sharp control on the operator ordering sensitivity of classical states we obtain a precise geometric image of their location in the density matrix space allowing us to introduce a distance-based measure of nonclassicality.
View Article and Find Full Text PDFWe report on the observation of broadband (40 THz) bright twin beams through high-gain parametric downconversion in an aperiodically poled lithium niobate crystal. The output photon number is shown to scale exponentially with the pump power and not with the pump amplitude, as in homogeneous crystals. Photon number correlations and the number of frequency/temporal modes are assessed by spectral covariance measurements.
View Article and Find Full Text PDF