Boron Neutron Capture Therapy (BNCT) represents a revolutionary approach in targeted radiation treatment for cancer. While the therapy's potential in precise targeting is well-recognized, a critical bottleneck remains in the accurate positioning of patients for treatment delivery. This study proposes a novel automated robotic-assisted patient positioning system specifically engineered for BNCT applications.
View Article and Find Full Text PDFThis study introduces the MKM_B model, an approach derived from the MKM model, designed to evaluate the biological effectiveness of Boron Neutron Capture Therapy (BNCT) in the face of challenges from varying microscopic boron distributions. The model introduces a boron compensation factor, allowing for the assessment of compound Biological Effectiveness (CBE) values for different boron distributions. Utilizing the TOPAS simulation platform, the lineal energy spectrum of particles in BNCT was simulated, and the sensitivity of the MKM_B model to parameter variations and the influence of cell size on the model were thoroughly investigated.
View Article and Find Full Text PDFBackground: Cherenkov luminescence imaging has shown potential for relative dose distribution and field verification in radiation therapy. However, to date, limited research utilizing Cherenkov luminescence for absolute dose calibration has been conducted owing to uncertainties arising from camera positioning and tissue surface optical properties.
Purpose: This paper introduces a novel approach to multispectral Cherenkov luminescence imaging combined with Fricke-xylenol orange gel (FXG) film, termed MCIFF, which can enable online full-field absolute dose measurement.
Prompt gamma monitoring for the prediction of boron concentration is valuable for the dose calculation of boron neutron capture therapy (BNCT). This work proposes to use generative adversarial network (GAN) to predict the boron distribution based on Compton camera (CC) imaging quickly and provide a scientific basis for its application in BNCT. The BNCT and Compton imaging process was simulated, then the image reconstructed from the simulation and the contour of skin from CT are used as input, and the distribution of boron concentration from PET data is set as the output to train the network.
View Article and Find Full Text PDFIn this study, we analyzed the performance of a PbF crystal-based detector at proton range monitoring with Monte Carlo simulations. The correlations between the depth-dose and Cherenkov profiles showed that the changes in the peak position in the Cherenkov profiles corresponded to the changes in the corresponding depth-dose profiles. Moreover, the deviations between the changes in the peak positions in the two curves were generally less than 2 mm.
View Article and Find Full Text PDFIn Boron Neutron Capture Therapy, the boronated drug plays a leading role in delivering a lethal dose to the tumour. The effectiveness depends on the boron macroscopic concentration and on its distribution at sub-cellular level. This work shows a way to colocalize alpha particles and lithium ions tracks with cells.
View Article and Find Full Text PDFThis study firstly explored the risks of secondary cancer in healthy organs of Chinese paediatric patients with brain tumours after boron neutron capture therapy (BNCT). Three neutron beam irradiation geometries (i.e.
View Article and Find Full Text PDFAustralas Phys Eng Sci Med
June 2019
Cerenkov luminescence imaging (CLI) is an emerging optical imaging technique, which has been widely investigated for biological imaging. In this study, we proposed to integrate the CLI technique with the radionuclide treatment as a "see-and-treat" approach, and evaluated the performance of the pinhole collimator-based CLI technique. The detection of Cerenkov luminescence during radionuclide therapy was simulated using the Monte Carlo technique for breast cancer treatment as an example.
View Article and Find Full Text PDFThis paper was aimed to explore the physics of Cherenkov radiation and its potential application in boron neutron capture therapy (BNCT). The Monte Carlo toolkit Geant4 was used to simulate the interaction between the epithermal neutron beam and the phantom containing boron-10. Results showed that Cherenkov photons can only be generated from secondary charged particles of gamma rays in BNCT, in which the 2.
View Article and Find Full Text PDFBackground: Magnetic resonance imaging (MRI)-guided radiotherapy is a promising image-guided cancer radiotherapy method. For MRI-guided radiotherapy, the proper energy of a therapeutic beam is important for beam-designing processes, and the magnetic-induced dose perturbation would be mainly influenced, especially the perturbation surrounding the tissue-air or air-tissue interfaces. Thus, it was necessary to investigate the impact of beam energy from photon, proton, and carbon ion beams on the magnetic-induced dose perturbations.
View Article and Find Full Text PDFAustralas Phys Eng Sci Med
September 2017
This work aims to determine the relationship between Cerenkov photon emission and radiation dose from internal radionuclide irradiation. Water and thyroid phantoms were used to simulate the distribution of Cerenkov photon emission and dose deposition through Monte Carlo method. The relationship between Cerenkov photon emission and dose deposition was quantitatively analyzed.
View Article and Find Full Text PDFPurpose: This work investigated whether the Bragg peak (BP) positions of proton beams can be modulated to produce uniform doses and cover a tumor under the magnetic fields inside cancer patients, and whether magnetic field modulated proton therapy (MMPT) is effective in vital organ protection.
Methods: The authors initially constructed an ideal water phantom comprising a central tumor surrounded by cuboid organ regions using GEANT4. Second, we designed the proton beams passing through the gap between two adjacent organ regions during beam configuration.
Optimization of the Compton camera for measuring prompt gamma rays (0.478MeV) emitted during boron neutron capture therapy (BNCT) was performed with Geant4. The parameters of the Compton camera were determined as follows: 3cm thick - 10cm wide scatter detector (Silicon), 10cm thick - 10cm wide absorber detector (Germanium), and 1cm distance between the scatter and absorber detectors.
View Article and Find Full Text PDFBoron Neutron Capture Therapy (BNCT) is a radiotherapy that combines biological targeting and high Linear Energy Transfer (LET). It is considered a potential therapeutic approach for non-small cell lung cancer (NSCLC). It could avoid the inaccurate treatment caused by the lung motion during radiotherapy, because the dose deposition mainly depends on the boron localization and neutron source.
View Article and Find Full Text PDFThe active shielding technique has great potential for radiation protection in space exploration because it has the advantage of a significant mass saving compared with the passive shielding technique. This paper demonstrates a Monte Carlo-based approach to evaluating the shielding effectiveness of the active shielding technique using confined magnetic fields (CMFs). The International Commission on Radiological Protection reference anthropomorphic phantom, as well as the toroidal CMF, was modeled using the Monte Carlo toolkit Geant4.
View Article and Find Full Text PDFThe S values for the thyroid as the radioiodine source organ to other target organs were investigated using Chinese hybrid reference phantoms and the Monte Carlo code MCNP5. Two radioiodine isotopes (125)I and (131)I uniformly distributed in the thyroid were investigated separately. We compared our S values for (131)I in Chinese phantoms with previous studies using other types of phantoms: Oak Ridge National Laboratory (ORNL) stylized phantoms, International Commission on Radiological Protection (ICRP) voxel phantoms, and University of Florida (UF) phantoms.
View Article and Find Full Text PDFThe purpose of this study is to verify the feasibility of applying GEANT4 (version 10.01) in neutron dose calculations in radiation protection by comparing the calculation results with MCNP5. The depth dose distributions are investigated in a homogeneous phantom, and the fluence-to-dose conversion coefficients are calculated for different organs in the Chinese hybrid male phantom for neutrons with energy ranging from 1 × 10(-9) to 10 MeV.
View Article and Find Full Text PDF