Introduction And Hypothesis: Midurethral sling procedures are the first surgical option in women undergoing surgery for stress urinary incontinence (SUI). Single-incision midurethral-slings (SIMS) were designed to provide similar efficacy to traditional midurethral slings but with reduced morbidity. In this international trial we compared the efficacy of a SIMS (MiniArc) and a transobturator standard midurethral sling (SMUS; Monarc) in the treatment of SUI in terms of subjective and objective cure rates and morbidity over a long-term follow-up.

View Article and Find Full Text PDF

Objectives: To evaluate the expression of the Rho/Rho-associated protein kinase (ROCK) pathway in the corpus cavernosum of patients with severe erectile dysfunction (ED) compared with healthy human corpus cavernosum, and to test the functional effects of two Rho kinase inhibitors (RKIs) on erectile tissue of patients with severe ED, which did not respond to phosphodiesterase type 5 inhibitors (PDE5Is).

Patients And Methods: Human corpus cavernosum samples were obtained after consent from men undergoing penile prosthesis implantation (n = 7 for organ bath experiments, n = 17 for quantitative PCR [qPCR]). Potent control subjects (n = 5) underwent penile needle biopsy.

View Article and Find Full Text PDF

Aims: To compare efficacy and safety of two commercially available single incision slings (SIS) and trans-obturator vaginal tapes (TOT), namely MiniArc™ and Monarc™ slings, and report the results at 5-year follow-up.

Methods: A retrospective-observational study of prospectively collected data was conducted on 381 women with primary stress urinary incontinence (SUI) in a single tertiary referral center. Patients treated with MiniArc™ and Monarc™ were compared.

View Article and Find Full Text PDF

Background: Midurethral sling procedures have become the prime surgical treatment for women with stress urinary incontinence (SUI). Single-incision mini-slings (SIMS) potentially offer similar efficacy with reduced morbidity. This international multicenter trial compared the efficacy and morbidity of a SIMS (MiniArc) and a transobturator standard midurethral sling (SMUS) (Monarc).

View Article and Find Full Text PDF

Context: The European Association of Urology (EAU) guidelines on urinary incontinence published in March 2012 have been rewritten based on an independent systematic review carried out by the EAU guidelines panel using a sustainable methodology.

Objective: We present a short version here of the full guidelines on the surgical treatment of patients with urinary incontinence, with the aim of dissemination to a wider audience.

Evidence Acquisition: Evidence appraisal included a pragmatic review of existing systematic reviews and independent new literature searches based on Population, Intervention, Comparator, Outcome (PICO) questions.

View Article and Find Full Text PDF

Context: The previous European Association of Urology (EAU) guidelines on urinary incontinence comprised a summary of sections of the 2009 International Consultation on Incontinence. A decision was made in 2010 to rewrite these guidelines based on an independent systematic review carried out by the EAU guidelines panel, using a sustainable methodology.

Objective: We present a short version of the full guidelines on assessment, diagnosis, and nonsurgical treatment of urinary incontinence, with the aim of increasing their dissemination.

View Article and Find Full Text PDF