Background And Purpose: TomoDirect (TD) can only operate in free-breathing. The purpose of this study is to compare TD with breath-hold 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) techniques for left breast treatments, and to determine if the lack of respiratory gating is a handicap for cardiac sparing.
Materials And Methods: 15 patients treated for left breast had two computed tomography simulation, in free breathing (FB) and in deep-inspiration breath-hold (DIBH).
Background And Purpose: To determine the optimum combination of treatment parameters between pitch, field width (FW) and modulation factor (MF) for extremity sarcomas in tomotherapy.
Materials And Methods: Six patients previously treated for extremity sarcomas (3 arms and 3 legs) with tomotherapy were included in this study. 288 treatment plans were recalculated, corresponding to all combinations between 2 FW (2.