Metal-organic framework composites have the advantages of large surface area, high porosity, strong catalytic efficiency and good stability, which provide a great possibility of finding excellent electrode materials for electrochemical sensors. However, MOF composites still face various challenges and difficulties, which limit their development and application. This paper reviews the application of MOF composites in electrochemical sensors, including MOF/carbon composites, MOF/metal nanoparticle composites, MOF/metal oxide composites and MOF/enzyme composites.
View Article and Find Full Text PDFAcute influenza infection has been reported to be associated with neurological symptoms such as influenza-associated encephalopathy (IAE). Although the pathophysiology of this condition remain unclear, neuroinflammation and associated alterations in the central nervous system (CNS) are usually induced. Microglia (MGs), CNS-resident macrophages, are generally the first cells to be activated in response to brain infection or damage.
View Article and Find Full Text PDFZhongguo Yi Liao Qi Xie Za Zhi
November 2021
A software platform for AI-ECG algorithm research is designed and implemented to better serve the research of ECG artificial intelligence classification algorithm and to solve the problem of subjects data information management. Matlab R2019b and MySQL Sever 8.0 are used to design the software platform.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
Premature ventricular contraction (PVC) is associated to the risk of ventricular dysfunction and cardiovascular events. Its diagnosis depends on a long-time monitoring, and computational tools for PVC recognition can provide significant assistance to specialists. For this purpose, we present an automatic algorithm for the recognition PVC beat based on long-term 12-lead ECG.
View Article and Find Full Text PDFA new electrochemical sensor was fabricated for the sensitive and selective detection of acetaminophen (AP), based on a bare glassy carbon electrode (GCE) modified with poly caffeic acid (PCA) and Zn/Ni-ZIF-8-800 using an electro-polymerization method. The carbon material of Zn/Ni-ZIF-8-800 derived from bimetal-organic framework was synthesized by one-step pyrolysis method. Then, the as-prepared materials and the corresponding fabricated sensors were fully characterized by XRD, FTIR, BET, SEM, TEM and XPS analyses.
View Article and Find Full Text PDFBing Du Xue Bao
September 2016
To explore the mechanisms of influenza H7N9 virus pathogenesis, influenza H7N9 virus and H1N1 influenza A virus(H1N1pdm09)-infected A549 cellular models were established, and differential protein expression in A549 cells infected with the two strains were investigated.A549 cells were infected with H7N9 and H1N1pdm09influenza virus at a multiplicity of infection(MOI)of 0.001.
View Article and Find Full Text PDFA newly emerged H7N9 influenza virus poses high risk to human beings. However, the pathogenic mechanism of the virus remains unclear. The temporal response of primary human alveolar adenocarcinoma epithelial cells (A549) infected with H7N9 influenza virus and H1N1 influenza A virus (H1N1, pdm09) were evaluated using the proteomics approaches (2D-DIGE combined with MALDI-TOF-MS/MS) at 24, 48 and 72 hours post of the infection (hpi).
View Article and Find Full Text PDFZhonghua Fu Chan Ke Za Zhi
January 2005
Objective: To determine the correlative factors with recurrence of endometriosis after conservative surgery.
Methods: A cohort study was performed on 285 patients who had a minimum of 36 months of follow-up after conservative surgery for endometriosis. All patients underwent clinical interview, physical examination and ultrasonography.
Objective: To evaluate the surgery in simple ovarian cysts.
Methods: From Jan. 1994 to Dec.