Commercially available hyaluronic acid dermal fillers used as a scaffold in regenerative endodontic procedures (REPs) have demonstrated attractive potentials. This study aimed to histologically evaluate the outcome of REPs using Restylane Lyft (HA) as a scaffold. REPs were performed on pulpless, immature roots in dogs (n = 69).
View Article and Find Full Text PDFScaffolds are crucial elements for dental pulp regeneration. Most of the currently used scaffolds in regenerative endodontic procedures (REPs) are unsuitable for chairside clinical use. This study aimed to evaluate the effect of an injectable synthetic scaffold (Restylane Lyft) on human bone marrow mesenchymal stem cell (hBMSC) viability, proliferation, and osteo/dentinogenic differentiation in a regenerative endodontic organotype model (REM).
View Article and Find Full Text PDFTruNatomy (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) is a newly released system that was not tested in any previous studies. The objective of this work is to evaluate cyclic fatigue resistance of the new file and compare it with the Twisted Files (TF) and ProTaper Next (PTN). Forty-five files were distributed into 3 groups: PTN X2 (size 25 and taper 0.
View Article and Find Full Text PDFBackground: The aim of this study was to evaluate the incidence and the location of fenestrations in a young Italian population by using CBCT.
Materials And Methods: Fifty patients who had previously performed CBCT for planning third molar extraction or orthodontic therapy were selected for the study. No previous dental treatment had been performed on these patients.
Objectives: The aim of the present study was to investigate the incidence of deformation and fracture of twisted file adaptive nickel-titanium instruments after repeated clinical use and to identify and check whether the three instruments within the small/medium sequence showed similar or different visible signs of metal fatigue.
Material And Methods: One-hundred twenty twisted file adaptive (TFA) packs were collected after clinically used to prepare three molars and were inspected for deformations and fracture.
Results: The overall incidence of deformation was 22.
Aim: The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.
Materials And Methods: Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .
Aim: To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite.
Methods: Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.
Aim: To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use.
Methods: 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy.
Objectives: The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary.
Material And Methods: 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively TFA motor (SybronEndo, Glendora, CA, USA) and Silver motor (VDW, Munich, Germany). The device used for the cutting test consisted on a mainframe to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested.
J Int Oral Health
January 2015
Background: The multiple uses of HyFlex(®) controlled memory (CM) rotary instruments (Coltene-Whaledent, Allstetten, Switzerland) have been recommended after sterilization. The purpose of this study was to analyze the surface defects on HyFlex(®) instruments after use and to determine their ability to return to their original shape after autoclaving.
Materials And Methods: Twenty-four new HyFlex(®) files were scanned using micro-computed tomography before the initial use, after use until defects were visible and after autoclaving.
Purpose: The purpose of the present study was to investigate and compare the effect of different reciprocating movements and angles on the shaping ability of the WaveOne and the single-fle ProTaper F2 using cone beam computed tomography (CBCT).
Materials And Methods: The mesiobuccal canals of 40 extracted maxillary molars, with curvatures of 20 to 45° were coded and randomly divided into 4 equal experimental groups according to the instrument used (ProTaper F2 fle and Wa-veOne) and the reciprocation range, for both instruments, a 150° angle was used for cutting and a 30° angle was used for release. Group 1 - WaveOne primary 150° CCW rotation angle and 30° CW rotation angle; Group 2 - WaveOne 90° CCW rotation angle and 30° CW rotation angle; Group 3 - ProTaper F2 150° CW rotation angle and 30° CCW rotation angle; Group 4 - ProTaper F2 90° CW rotation angle and 30° CCW rotation angle.
The aim of the present study was to compare the cutting efficiency of Twisted File instruments used in continuous rotation or TF Adaptive motion and evaluate if prolonged use significantly affected their cutting ability. 20 new NiTi instruments were used in the present study (TF tip size 35, 0.06 taper; Sybron-Endo, Orange, CA, USA), divided into 2 subgroups of 10 instruments each, depending on which movement was selected on the endodontic motor.
View Article and Find Full Text PDFAim: The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography.
Study Design: Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to micro-computed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments.
Aim: The manual files are still widely used for initial canal negotiation prior the use of nickel-titanium shaping instruments, to determine working length and to verify patency. A mechanical glide path can be performed using manual files with handpieces, such as M4 Handpiece (SybronEndo, USA) that allows a 30°/30° reciprocating motion. The Pathfinders (SybronEndo, USA) are hand files designed to negotiate complex canals, made from stainless steel (SS) or carbon steel (CS) alloys.
View Article and Find Full Text PDFBackground: The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments.
Material And Methods: Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested.
Endodontic glide path is the creation of a smooth patency from canal orifice to apex, which can be performed manually or with small tapered NiTi rotary instruments. The use of stainless steel (SS) hand K-files inserted in a reciprocating handpiece can be a possible alternative to create a mechanical glide path. The aim of this study was to compare the cyclic fatigue resistance between SS K-files used in a reciprocating motion and NiTi rotary instruments in artificial curved canals.
View Article and Find Full Text PDFObjectives: The purpose of the study was to investigate and evaluate the professional attitudes and behaviors acquired by students and recently graduated dentists during undergraduate education at King Saud University.
Methods: This cross-sectional survey used a 27-item questionnaire covering four cumulative theoretical dimensions of professionalism. Questionnaires were distributed to fifth-year students, interns, and demonstrators in the College of Dentistry during the academic year 2010-2011, and 203 completed questionnaires were used in analyses.
Aims: Apical extrusion of infected debris to the periradicular tissues is one of the principal causes of postoperative pain and discomfort. Recent researches have shown that reciprocating instrumentation techniques seem to significantly increase the amount of debris extruded beyond the apex and, consequently, the risk of postoperative pain. The goal of the present study was to evaluate and compare postoperative pain using three different nickel-titanium instrumentation techniques: a rotary crown-down technique using TF instruments (SybronEndo, Orange, Ca), a reciprocating single-file technique using WaveOne instruments (Maillefer DEntsply, Baillagues, CH), and a novel instrumentation technique (TF Adaptive, SybronEndo, Orange, Ca), using a unique, proprietary movement, combining reciprocation and continuous rotation.
View Article and Find Full Text PDFAim: The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test.
View Article and Find Full Text PDFObjectives: The aims of this study were to conduct a morphometric analysis on the buccal furcation grooves in freshly extracted bifurcated maxillary first premolars (MFPs) and to correlate all anatomical measurements using microcomputed tomography.
Materials And Methods: Twenty-three human MFPs with bifurcated canals were selected for this study. The specimens were analyzed with microcomputed tomography.
The aim of this study was to investigate whether cyclic fatigue resistance is increased for Controlled Memory (CM) Nickel-Titanium (NiTi) instruments, compared to instruments produced using traditional NiTi and instruments produced using M-Wire alloy. Two groups of NiTi endodontic instruments consisting of identical instrument sizes (constant 0.06 taper and 0.
View Article and Find Full Text PDFIntroduction: The purpose of this study was to evaluate cyclic fatigue fracture resistance of engine-driven nickel-titanium (K3XF) instruments under reciprocating movement in various angles.
Methods: Fifty K3XF size 40 taper 0.06 nickel-titanium instruments were divided randomly into 5 groups of 10 each.
Introduction: The goal of the present study was to test the fatigue resistance of nickel-titanium rotary files in a double curvature (S-shaped) artificial root canal and to compare those results with single curvature artificial root canals.
Methods: Two nickel-titanium endodontic instruments consisting of identical instrument sizes (constant .06 taper and 0.
Background: The aim of the present study was to evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments after clinical use by 1 experienced and 1 novice operator.
Material/methods: Cyclic fatigue testing of instruments was performed on tapered artificial canals with a 5 mm radius of curvature and 60° angle of curvature. Twenty Mtwo instruments for each size were selected and divided into 2 groups: group A consisted of 10 instruments of each size used for shaping 10 root canals in molar teeth of patients by an experienced operator; group B consisted of 10 instruments of each size used for shaping 10 root canals in molar teeth of patients by a novice operator.