Publications by authors named "Dimorvan Bordin"

The present short-term retrospective study evaluated the implant survival rate and peri-implant bone loss around additive-manufactured titanium implants placed in sinuses grafted with Plenum Osshp (Plenum Bioengenharia, Jundia, SP, Brazil) (70HA:30β-TCP) material. A total of 39 implants were inserted after 23 sinus floor elevation procedures in 16 consecutive patients. Prosthetic rehabilitation included fixed partial prostheses (three units), single crowns (eleven units), and fixed full arches (three units).

View Article and Find Full Text PDF

This study aimed to evaluate the influence of material and crown design on the biomechanical behavior of implant-supported crowns with hybrid abutment (HA) through three-dimensional (3D) finite element analysis. The study factors were the type of material used as the mesostructure or crown (zirconia, lithium disilicate, and hybrid ceramic) and the crown design cemented to the titanium base (mesostructure cemented to the titanium base and a crown cemented on it (HaC); hybrid crown-abutment, the abutment and crown are manufactured as a single piece and cemented to the titanium base (HC); monolithic crown cemented on the titanium base and screwed to the implant (CS); and monolithic crown cemented on the titanium base (CC). Four 3D models were constructed using an implant with an internal connection, and an oblique load of 130 N was applied at 45° to the long axis of the implant.

View Article and Find Full Text PDF

Introduction: This study aimed to evaluate the effectiveness of dental bleaching with hydrogen peroxide 35% on the surface below the attachments.

Methods: Twenty-four blocks of bovine incisors were equally divided into 2 groups. The control group comprises the enamel surface free of attachments, whereas the attachment group comprises the enamel surface with attachment.

View Article and Find Full Text PDF

Unlabelled: Glass ceramics' fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness.

Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments.

View Article and Find Full Text PDF

Objectives: To characterize the mechanical and biological properties of three commercially available resins, which are currently used for provisional restorations and to compare them to an experimental resin intended for definitive fixed dental prostheses.

Materials And Methods: Three commercially available resins: Crowntec (CT, Saremco), Temporary C&B (FL, Formlabs), C&B MFH (ND, Nextdent), and the experimental resin: Permanent Bridge (PB, Saremco) were printed and subjected to biaxial flexural strength test, finite element analysis, Weibull analysis, scanning electron microscopy, cell proliferation, immunohistochemistry and cytotoxicity assays. Samples from CT, PB, and ND were provided directly from the manufacturers ensuring ideal workflow.

View Article and Find Full Text PDF

Purpose: This study evaluated the effect of different tightening protocols on the probability of survival of screw-retained implant-supported anterior crowns.

Materials And Methods: Seventy-two implants with internal conical connections (4.0 × 10mm, Ti-6Al-4V, Colosso, Emfils) were divided into four groups (n = 18 each): 1) Manufacturer's recommendations torque (25 N.

View Article and Find Full Text PDF

The objective of this study was to compare the biomechanical behavior of peri-implant bone tissue and prosthetic components in two modalities of treatment for posterior region of the maxilla, using short implants or standard-length implants associated with bone graft in the maxillary sinus. Four 3D models of a crown supported by an implant fixed in the posterior maxilla were constructed. The type of implant: short implant (S) or standard-length implant with the presence of sinus graft (L) and type of crown retention: cemented (C) or screwed (S) were the study factors.

View Article and Find Full Text PDF

A recently developed orthodontic wire alloy known as GUMMETAL® is claimed to deliver more physiological forces to correct dental mispositioning. However, its mechanical characteristics have not been fully characterized yet. This study aimed to determine and compare the elastic properties of different wire alloys, such as nickel-titanium (NiTi), stainless steel (SS), and GUMMETAL®, and assess their unloading forces when combined with either conventional or self-ligating brackets (CL and SL) when correcting dental crowding.

View Article and Find Full Text PDF

Objectives: This animal study was conducted to evaluate the osteocyte index in the peri-implant bone around immediately restored implants under static lateral overload.

Material And Methods: Seven mongrel dogs received three implants on each side of the mandible. Forty-two implants were distributed into three groups (14 implants per group); each animal received two implants connected to a 4.

View Article and Find Full Text PDF

Objectives: to evaluate the probability of survival and failure modes of lithium-disilicate, feldspathic-ceramic, and resin-nanoceramic anterior veneers cemented on dentin analog substrates after sliding-contact step-stress accelerated life testing (SSALT).

Methods: A virtual incisor tooth preparation was produced with a reduction of 1.5mm at the incisal edge and of 0.

View Article and Find Full Text PDF

Observational studies have indicated that crestal bone level changes at implants are typically associated with clinical signs of inflammation, but still mechanical overload has been described as possible factor leading to hard-tissue deficiencies at implant sites without mucosal inflammation. The aim of this paper was systematically review the literature regarding the possible effect of traumatic occlusal forces on the peri-implant bone levels. Literature search was conducted using PubMed, Scielo and Lilacs, including the following terms: oral OR dental AND implant$ AND (load OR overload OR excessive load OR force$ OR bruxism) AND (bone loss OR bone resorption OR implant failure$).

View Article and Find Full Text PDF

This in silico study evaluated the influence of the abutment collar height and implants length on the biomechanical behavior of morse taper single dental implants with different crown-to-implant ratio. Six virtual models were constructed (S11, M11, L11, S13, M13 and L13) by combining short (S: 2.5 mm), medium (M: 3.

View Article and Find Full Text PDF

Objective: To evaluate the reliability and failure mode of zirconia-reinforced lithium silicate (ZLS) molar crowns of different thicknesses.

Methods: Monolithic ZLS molar crowns (0.5mm, 1.

View Article and Find Full Text PDF

Objective: To compare hard-tissue healing after 3 exodontia approaches.

Materials And Methods: Premolars of dogs were extracted: (1) flapless, (2) flap, and (3) flap + socket coverage with polytetrafluoroethylene (dPTFE) nonresorbable membrane (flap + dPTFE). Animals were euthanized at 1 and 4 weeks.

View Article and Find Full Text PDF

Objectives: This randomized split-mouth clinical trial investigated the influence of implant macrogeometry on bone properties and peri-implant health parameters during the healing process.

Material And Methods: Ninety-nine implants were placed bilaterally in posterior mandibles of 23 patients that received at least four dental implant macrogeometries: standard geometry, Integra (IN) and three geometries inducing "healing chamber": Duo (D), Compact (C), and Infra (IF). Insertion torque (IT) and implant stability quotient (ISQ) were measured.

View Article and Find Full Text PDF

Objective: To characterize the mechanical properties of different coating methods of DLC (diamond-like carbon) onto dental implant abutment screws, and their effect on the probability of survival (reliability).

Methods: Seventy-five abutment screws were allocated into three groups according to the coating method: control (no coating); UMS - DLC applied through unbalanced magnetron sputtering; RFPA-DLC applied through radio frequency plasma-activated (n=25/group). Twelve screws (n=4) were used to determine the hardness and Young's modulus (YM).

View Article and Find Full Text PDF

This study evaluated the influence of polishing protocols on the surface roughness of flowable and regular bulk fill composites. Five bulk fill composites were tested: SureFil SDR Flow (SDR), Tetric EvoFlow Bulk fill (TEF), Filtek Bulk Fill Flowable (FIF), Tetric EvoCeram Bulk Fill (TEC), and Filtek Bulk Fill Posterior (FIP). Two polishing protocols were tested: Sof-Lex and Astropol.

View Article and Find Full Text PDF

Objective: To evaluate the residual stress (nanoindentation based on hardness) of fatigued porcelain-fused to zirconia 3-unit fixed dental prostheses (FDP) with different framework designs.

Methods: Twenty maxillary 3-unit FDP replacing second-premolar (pontic) were fabricated with conventional framework-design (even-thickness of 0.5mm and 9mm connector area) and modified framework-design (thickness of 0.

View Article and Find Full Text PDF

Purpose: To evaluate the influence of implant diameter in the reliability and failure mode of extra-short dental implants.

Materials And Methods: Sixty-three extra-short implants (5mm-length) were allocated into three groups according to platform diameter: Ø4.0-mm, Ø5.

View Article and Find Full Text PDF

Objective: In this study, marginal and internal misfit and fracture load with and without thermal-mechanical aging (TMA) of monolithic ZLS and lithium disilicate (LDS) crowns were evaluated.

Material And Methods: Crowns were milled using a computer-aided design/computer-aided manufacturing system. Marginal gaps (MGs), absolute marginal discrepancy (AMD), axial gaps, and occlusal gaps were measured by X-ray microtomography (n=8).

View Article and Find Full Text PDF

The use of analogs could reduce the cost of mechanical tests involving implant-supported crowns, but it is unclear if it would negatively affect the data accuracy. This study evaluated the substitution of the implant by implants analogs or abutment analogs as a support for crowns in mechanical tests, taking into account stress distribution and fracture load of monolithic lithium disilicate crowns. Thirty lithium disilicate monolithic crowns were randomized into three groups according to the set: Implant+abutment (IA); implant analog+abutment (IAA); abutment analog (AA).

View Article and Find Full Text PDF

Purpose: To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters.

Materials And Methods: For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the influence of implant macrodesign when using different types of collar and thread designs on stress/strain distributions in a maxillary bone site.

Materials And Methods: Six groups were obtained from the combination of two collar designs (smooth and microthread) and three thread shapes (square, trapezoidal, and triangular) in external hexagon implants (4 × 10 mm) supporting a single zirconia crown in the maxillary first molar region. A 200-N axial occlusal load was applied to the crown, and measurements were made of the von Mises stress (σ) for the implant, and tensile stress (σ), shear stress (τ), and strain (ε) for the surrounding bone using tridimensional finite element analysis.

View Article and Find Full Text PDF

Purpose: To evaluate the reliability of narrow diameter dental implants (NDIs) with similar macrogeometry and 3 implant-abutment connection designs.

Materials And Methods: Eighty-four NDIs (3.5 × 10 mm) were selected and divided into 4 groups (n = 21/group) according to implant-abutment connection design, as follows: EH - external hexagon, IH - internal hexagon, IC - internal conical, and IC-M - internal conical connected to a monolithic titanium abutment.

View Article and Find Full Text PDF

Purpose: Evaluate the influence of abutment's material and geometry on stress distribution in a single implant-supported prosthesis.

Materials And Methods: Three-dimensional models were made based on tomographic slices of the upper middle incisor area, in which a morse taper implant was positioned and a titanium (Ti) or zirconia (ZrN) universal abutments was installed. The commercially available geometry of titanium (T) and zirconia (Z) abutments were used to draw two models, TM1 and ZM1 respectively, which served as control groups.

View Article and Find Full Text PDF