Aim: The traditional hinge axis theory of temporomandibular joint (TMJ) dynamics is increasingly being replaced by the theory of instantaneous centers of rotation (ICR). Typically, ICR determinations are based on theoretical calculations or three-dimensional approximations of finite element models.
Materials And Methods: With the advent of real-time magnetic resonance imaging (MRI), natural physiologic movements of the TMJ may be visualized with 15 frames per second.
Purpose: The aim of this study was to examine possible parameters correlating to the shape of the curve of Spee (COS) by analyzing multiple setups of the same Angle class I patient case.
Methods: In all, 65 setups of the same Angle class I patient case were constructed. We measured the depth of the COS, length and width of the dental arch, steps, rotations, spaces and symmetry of the constructed setups.
Background: Elongated styloid processes may display clinical signs that can easily be confused with symptoms associated with temporomandibular disorders (TMD). Thus, the present study aimed to investigate alterations of the styloid process in patients with TMD.
Methods: Temporomandibular joint (TMJ) X-ray images of 192 patients with RDC/TMD diagnoses were examined retrospectively.
Purpose: The kinematical properties of C5/C6 segments in axial rotation are evaluated before and after total disc arthroplasty (TDA) with PRESTIGE-and BRYAN Cervical Disc (Medtronic) under flexion/extension as parameters and compared with those of C3/C4.
Methods: Eight human segments were stimulated by triangularly varying, axially directed torque (T (t)) under compressing static axial preloads. Using a 6D-measuring device with high resolution, the response of segmental motion was characterized by the instantaneous helical axis (IHA).
Purpose: We investigate the dependence of the kinematics of the human knee on its anatomy. The idea of describing the kinematics of the knee in the sagittal plane using four-bar linkage is almost as old as kinematics as an independent discipline. We start with a comparison of known four-bar linkage constructions.
View Article and Find Full Text PDFPurpose: The curvature morphology of the articulating surfaces determines the physiological movement pattern. We quantitatively examined the curvature morphology of the tibiotalar articulating surfaces and specified their geometric contact patterns.
Methods: Geometrically equivalent cartographic nets were marked on the talar and tibial articulating surfaces of true-to-scale moldings of 20 human ankle joints (intervals of 5 mm) to relate corresponding articulating units of the surfaces.
Purpose: The purpose is to present a mathematical model of the function of the thumb carpometacarpal joint (TCMCJ) based on measurements of human joints. In the TCMCJ both articulating surfaces are saddle-shaped. The aim was to geometrically survey the shapes of the articulating surfaces using precise replicas of 28 TCMCJs.
View Article and Find Full Text PDFPurpose: In comparative examinations of kinematics of the knees of humans and pigs in flexional/extensional motion under compressive loads, the significant differential geometric essentials of articular guidance are elaborated to criticise the shaping of the articular surfaces of conventional knee-endoprostheses and to suggest constructional outlines that allow the endoprosthesis to adopt natural knee kinematics. Implantation is discussed with regard to the remaining ligamentous apparatus.
Methods: Twelve fresh pig knee joints and 19 preserved human knee joints were moved into several flexional/extensional positions.
Purpose: We present a novel method to process kinematical data typically coming from measurements of joints. This method will be illustrated through two examples.
Methods: We adopt theoretical kinematics together with the principle of least action.
The center of resistance is a concept in theoretical orthodontics used to describe tooth movement under loads. It is commonly used to qualitatively predict tooth movement without recourse to complex equations or simulations. We start with a survey of the historical origin of the technical term.
View Article and Find Full Text PDFWe analyze how kinematic properties of C3/C4-segments are modified after total disc arthroplasty (TDA) with PRESTIGE(®) and BRYAN(®) Cervical Discs. The measurements were focused on small ranges of axial rotation (<0.8°) in order to investigate physiologic rotations, which frequently occur in vivo.
View Article and Find Full Text PDFObjective: Methionine is an essential amino acid and pivotal for normal growth and development. However, previous animal studies have shown that excessive maternal intake of methionine causes growth restrictions, organ damages, and abnormal growth of the mandible in newborn animals. However, the effect of excessive methionine on the development of the cranial growth plate is unknown.
View Article and Find Full Text PDFThe mathematical approach presented allows main features of kinematics and force transfer in the loaded natural tibiofemoral joint (TFJ) or in loaded knee endoprostheses with asymmetric condyles to be deduced from the spatial curvature morphology of the articulating surfaces. The mathematical considerations provide the theoretical background for the development of total knee replacements (TKR) which closely reproduce biomechanical features of the natural TFJ. The model demonstrates that in flexion/extension such kinematic features as centrodes or slip ratios can be implemented in distinct curvature designs of the contact trajectories in such a way that they conform to the kinematics of the natural TFJ in close approximation.
View Article and Find Full Text PDFFirstly, the way of implementing approximatively the initial rollback of the natural tibiofemoral joint (TFJ) in a total knee replacement (AEQUOS G1 TKR) is discussed. By configuration of the curvatures of the medial and lateral articulating surfaces a cam gear mechanism with positive drive can be installed, which works under force closure of the femoral and tibial surfaces. Briefly the geometric design features in flexion/extension are described and construction-conditioned kinematical and functional properties that arise are discussed.
View Article and Find Full Text PDFBackground And Objective: Six-base retainers are often used to prevent tertiary crowding. To minimize shear stress on the retainer, these should be fitted as precisely as possible. The aim of this study was to compare the accuracy of fit of 6-base retainers after adhesive fixation using a neodymium-iron-boron (NdFeB) magnet chain or a resin positioning aid.
View Article and Find Full Text PDFObjective: To conduct a pilot study to investigate the potentiality to determine the midpalatal sutural width radiographically with a flat-panel volume computed tomography (fpVCT) in a porcine model.
Materials And Methods: Bone samples from the midpalatal suture of five young (16 weeks) and five old (200 weeks) sus scrofa domestica were gathered. The midpalatal suture width was measured via fpVCT and compared to respective histological preparations.
Objective: To determine the forces and moments delivered to a maxillary central incisor during rotation with aligners when a simulated occlusal force generated during swallowing acts on the appliance.
Materials And Methods: Five identical appliances were manufactured from four different starting materials (Erkodur 0.8 mm and 1.
A novel class of total knee replacement (AEQUOS G1) is introduced which features a unique design of the articular surfaces. Based on the anatomy of the human knee and differing from all other prostheses, the lateral tibial "plateau" is convexly curved and the lateral femoral condyle is posteriorly shifted in relation to the medial femoral condyle. Under compressive forces the configuration of the articular surfaces of human knees constrains the relative motion of femur and tibia in flexion/extension.
View Article and Find Full Text PDFAfter total knee replacement the persistence of pain represents a significant problem. In this study, a novel knee arthroplasty (Aequos G1 knee arthroplasty) is investigated that was designed to replicate main features of human knee morphology to reduce the periodically occurring pain after knee replacement. Previous work showed theoretically that this arthroplasty design may reconstruct the four-bar linkage mechanism as it occurs in human knee by contriving a convex lateral tibial compartment and a sagittal offset of the centre of the medial and lateral femur condyles - inducing a roll-back mechanism as it exists in human.
View Article and Find Full Text PDFThe aim of the study was to establish whether juveniles with a Class II malocclusion change the neuromuscular control of mandibular movements during the course of orthodontic treatment with removable functional appliances (RFAs). Neuromuscular control can be indirectly evaluated by recording cyclic planar mandibular movements which were freely carried out by the patients (28 girls, 14 boys, aged 11.1 ± 1.
View Article and Find Full Text PDFObjective: To evaluate impulse debonding compared to three conventional methods for bracket removal in relation to the damage caused to the enamel surface.
Materials And Methods: Ninety-six osteotomed third molars were randomly assigned to two study groups (n = 48) for bracket bonding with either a composite adhesive system (CAS) or a glass-ionomeric cement (GIC). These two groups were then each randomly divided into four subgroups (n = 12) according to the method of debonding using (1) bracket removal pliers, (2) a side-cutter, (3) a lift-off debracketing instrument, or (4) an air pressure pulse device.
Aim: To test the null hypothesis that there are no significant differences in the reusability of debonded brackets with regard to debonding technique and adhesive used.
Method: Ninety-six osteotomed third molars were randomly assigned to two study groups (n = 48) for bonding of a 0.018-inch bracket (Ormesh, Ormco) with either a composite adhesive (Mono-Lok2; RMO) or a glass ionomer cement (GIC; Fuji Ortho LC;GC).
The forces delivered by aligners during torquing have still not been investigated. The purpose of this study was to measure the forces delivered to an upper central incisor during torquing with three different materials of the same thickness, and to describe the biomechanical principles of torquing with aligners. Five identical appliances were manufactured from each of three materials, all with a thickness of 1.
View Article and Find Full Text PDFThe biomechanical role of the zygapophysial joints was investigated for axial rotations of lumbar segments by recording the positions of the instantaneous helical axis (IHA) against the axial rotational angle and by relating these IHA-positions to anatomical landmarks. Cyclically varying pure axial moments were applied to 3 L1/L2, 7 L3/L4 and 3 L4/L5 segments. There were 800 segment positions per cycle taken by a custom-made high precision 3D-position measuring system.
View Article and Find Full Text PDFObjective: To determine the forces and moments delivered to a maxillary central incisor during rotation by three different thermoplastic appliances with identical thickness.
Materials And Methods: Five identical appliances were manufactured from each of three materials (Ideal Clear 1.0 mm, Erkodur 1.