The alveolar ridge splitting technique enables reconstruction of atrophied alveolar ridges prior implantation. However, in cases of severe atrophy, there is an unpredictable risk of fracturing the buccal lamella during the expansion. Currently, there is no preoperative assessment to predict the maximum distraction of the lamella.
View Article and Find Full Text PDFBackground: Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal.
View Article and Find Full Text PDFBackground: Arthrodesis of the medial column (navicular, cuneiform I and metatarsal I) is performed for reasons such as Charcot arthropathy, arthritis, posttraumatic reconstruction or severe pes planus. However, the complication rate is still high and mainly resulting from inadequate fixation. Special plates, designed for medial column arthrodesis, seem to offer potential to reduce the complication rate.
View Article and Find Full Text PDFPolyaxial locking screws are increasingly applied in fracture fixation. To investigate the durability of the head-locking mechanism, the removal torque of variable angle (VA) and fixed angle (FA) stainless steel and titanium locking screws was investigated without and after a cyclic loading test. Stainless steel (St) and titanium (Ti) 2.
View Article and Find Full Text PDFIntroduction: Treatment of posterior pelvic ring injuries is frequently associated with pain or/and high mortality rates. Percutaneous sacro-iliac (SI) screw fixation has proved to be one of the methods of choice, providing minimal operative time, blood loss and wound-related morbidity. However, fixation failures due to secondary fracture dislocation or screw backing out have been reported.
View Article and Find Full Text PDFLateral talar process fragment excision may be followed by hindfoot instability and altered biomechanics. There is controversy regarding the ideal fragment size for internal fixation versus excision and a concern that excision of a large fragment may lead to significant instability. The aim of this study was to assess the effect of a simulated large lateral talar process excision on ankle and subtalar joint stability.
View Article and Find Full Text PDFApplications for fracture-adapted screw positioning offered by variable angle locking screws are increasing. The locking strength of the variable angle locking mechanism at different insertion angles was compared to conventional fixed angle locking screws. Stainless steel (S) and titanium (Ti) variable and fixed angle 2.
View Article and Find Full Text PDFPurpose: The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS).
View Article and Find Full Text PDFA lot of new implant devices for spine surgery are coming onto the market, in which vertebral screws play a fundamental role. The new screws developed for surgery of spine deformities have to be compared to established systems. A biomechanical in vitro study was designed to assess the bone-screw interface fixation strength of seven different screws used for correction of scoliosis in spine surgery.
View Article and Find Full Text PDFIn 1997, the proximal femoral nail was introduced for treatment of peritrochanteric femoral fractures. Treatment results show a low complication rate. The most serious complication is cutout of the hip pin and femoral neck screw.
View Article and Find Full Text PDFObjective: To compare the mechanical properties of 2 configurations of a veterinary fixation system (VFS) for large animal long bones with dynamic compression plating (DCP).
Sample Population: Eighteen pairs of Canevasit tubes (Canevasit; Amsler und Frei, Schinznach Dorf, Switzerland) (length, 170 mm; diameter, 47.5 mm; cortex thickness, 10 mm), aligned with a 10-mm gap, and stabilized with 2 DCP or 2 VFS implants.