Shack-Hartmann wave-front sensing has been successfully applied to many fields of optical testing including the human eye itself. We propose wave-front measurement for testing protective eye wear for production control and investigation of aberrations. Refractive power data is derived from the wave-front data and compared to a subjective measurement technique based on a focimeter.
View Article and Find Full Text PDFWe describe and characterize a straightforward test setup for characterizing temporal and spectral dynamics of photochromic spectacle materials. Three measurement examples of contemporary silicate and organic photochromic spectacles are provided. The setup showed a good absolute accuracy of ≤5% of the luminous transmittance (τ(v)) and repeatability of better than 3%.
View Article and Find Full Text PDF