Objectives: The present parallel randomized clinical trial aimed to assess, after a 3-year follow-up period, whether the choice of surgical technique-either manual or guided-and of the operator - non-expert operator or skilled - can affect the stability of peri‑implant marginal bone levels in implants placed 1 mm sub-crestal.
Materials And Methods: Patients received platform-switched implants (Anyridge, MegaGen Implant Co., Gyeongbuk, South Korea) featuring a 5-degree internal conical connection and supporting single screw-retained fixed crowns.
Objective: To carry out a systematic review and meta-analysis of randomized controlled clinical trials (RCTs) and controlled clinical trials (CCTs) comparing scaling and root planing (SRP) or placebo with subgingival application of xanthan-based CHX (chlorhexidine) gel as adjunct to SRP.
Materials And Methods: The literature search was carried out in PubMed/MEDLINE, EMBASE, and SCOPUS; primary outcomes were probing pocket depth (PPD) reduction and gain in clinical attachment level (CAL).
Results: Overall, 15 studies were included.
Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments.
View Article and Find Full Text PDFBackground: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles.
Methods: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle (EA) measured at 3 years of follow-up visits (t1) were calculated for two different groups: Group 1 (153 implants) for restorations with angle between implant axis and prosthetic emergence angle from ≥30°, and Group 2 (67 implants) for those with angle ≤30°, respectively.
The aim of the present retrospective study was to assess marginal bone changes around implants restored with different prosthetic emergence profile angles. Patients were treated with implants supporting fixed dentures and were followed for 3 years. Marginal bone levels (MBL) measured at the prosthesis installation (t0) and at the 3-year follow-up visit (t1) were considered.
View Article and Find Full Text PDFThe esthetic success of a case requiring implant therapy mainly depends on both the correct planning and the surgical-prosthetic execution. However, planning and surgical implementation according to prosthetically guided criteria are not always possible due to contingent anatomical limitations. When this is further complicated by the presence of mucogingival deficiencies in a highly visible esthetic area, the management of the case can become very complex.
View Article and Find Full Text PDFTo verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed.
View Article and Find Full Text PDFImpression accuracy is fundamental to achieve a passive fit between implants and the superstructure. Three transfer types were tested to evaluate the differences in impression accuracy and their efficiency in case of different implant angles. A master model with four implant analogues placed at 0°, 15° and 35° was used.
View Article and Find Full Text PDFBackground: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal 5° conical connection placed in a subcrestal position.
Materials And Methods: Patients treated with fixed prostheses supported by implants placed at a subcrestal level between 2012 and 2018 were recalled for a follow-up examination.
This retrospective study evaluated hard and soft tissue response and reported mechanical and technical complications around computer-aided design/computer-assisted manufactured (CAD/CAM) abutments. A total of 123 patients restored with titanium, gold-hue titanium, and zirconia CAD/CAM abutments were included (N = 291). Each patient was followed up for at least 2 years.
View Article and Find Full Text PDFInt J Oral Implantol (Berl)
October 2019
Purpose: To evaluate the reliability of a conometric system for fixed retention of complete prostheses (CPs) on four implants after 5 years of function.
Materials And Methods: Twenty-five patients with a completely edentulous mandible received four implants supporting a CP. A total of 100 implants were immediately loaded with CPs on conometric abutments.
Int J Periodontics Restorative Dent
September 2018
The conometric retention system was proposed and described as a predictable alternative to retain fixed implant-supported complete dentures and, more recently, to retain fixed partial restorations. Currently available studies describe a technique based on the Ankylos (Dentsply) implant system and stock conic coupling abutments. The purpose of this case series study is therefore to demonstrate the possibility of using Atlantis computer-aided design/computer-assisted manufacture technology to produce Conus abutments (Dentsply) and using the fixed conometric retention with other implant brands for which appropriate stock conic coupling abutments are not available.
View Article and Find Full Text PDFPurpose: The aim of this in vitro study was to verify whether or not stock and computer-aided design/computer-aided manufacturing (CAD/CAM) abutments show similar precision in the connection with the respective implants.
Materials And Methods: Ten CAD/CAM titanium abutments were compared with 10 stock titanium abutments. Each abutment fit a regular-platform implant (Institute Straumann).
Objective: To evaluate in vitro the sealing capability at the prosthetic connection interface of 2 conometric systems.
Materials And Methods: Two conometric systems with the same design and different material were used, for a total of 24 samples. Each sample was assembled by a tapered abutment and respective coping.
Unlabelled: The aim of this study was to compare the interproximal papilla stability of restorations supported by computer-aided design/computer-assisted manufacture (CAD/CAM) abutments to those supported by prefabricated stock abutments in anterior areas over a 2-year follow-up. Abutments were selected depending on implant inclination and thickness of buccal peri-implant soft tissues from the following: zirconia stock, titanium stock, zirconia CAD/CAM and titanium CAD/CAM. Differences between the height of the papilla tip were measured (REC).
View Article and Find Full Text PDFAims: To evaluate the ridge dimensions of posterior sextant in totally edentulous mandibles.
Material And Methods: Cone beam computed tomography scans of 136 patients were retrospectively included for analysis. At sites corresponding to the second premolar (site a) and the mesial and distal root of first molar (sites b and c, respectively), bone height (BH) and bone width (BW) were measured.
Background And Objective: Subepithelial connective tissue grafts (SeCTG) in conjunction with a coronally advanced flap (CAF) or with tunneling technique (TT) are common periodontal procedures with similar indications for the treatment of a denuded root surface; however, it is unclear whether patient discomfort and postoperative morbidity are comparable in both approaches. The aim of this randomized controlled clinical trial was to compare the patient morbidity and root coverage outcomes of a SeCTG used in combination with a CAF or TT.
Materials And Methods: For this single-center, randomized, clinical trial, patients were randomly assigned to receive SeCTG + CAF (control group) or SeCTG + TT (test group).
Purpose: The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue in patients with thin gingival biotype.
Material And Methods: Thirty-seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all-ceramic crown has been tried on gold, titanium and zirconia abutment.
Objectives: Subgingival margin placement is sometimes required due to different reasons and is often associated with adverse periodontal reactions. The purpose of this study was to determine if a single restoration with subgingival margin on a tooth, in the maxillary anterior zone, would affect its periodontal soft tissue parameters, and whether or not a deep chamfer preparation has a different influence in the periodontium when compared to a feather edge preparation.
Material And Methods: Plaque and gingival indexes, periodontal probing depth, bleeding on probing, and patient's biotype were registered.
Purpose: The aim of this study was to transfer the provisional restoration emergence profile to the final implant-supported restoration and to buccal gingival margin (BGM) stability after 2 years of function.
Materials And Methods: A total of 33 patients were recruited for treatment of single gaps by means of 33 implant-supported restorations. Fixed provisional crowns were screwed to the fixture and adjusted until the complete peri-implant soft tissue maturation was achieved.
Purpose: The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years.
Material And Methods: Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever.
Int J Periodontics Restorative Dent
December 2016
The aim of this prospective randomized clinical study was to evaluate, by means of an image analysis system, the efficacy of two different surgical procedures for the treatment of Miller Class I and II maxillary gingival recession. Patients treated for maxillary gingival recession were recruited and randomly divided into two groups: patients who received a coronally advanced flap with connective tissue graft (CAF + CTG) or CAF alone. Outcome parameters included complete root coverage, recession reduction, and keratinized tissue amount.
View Article and Find Full Text PDFAim: Aim of this study was to verify if the type of implant abutment manufacturing, stock or cad-cam, could influence the maintenance of stable gingival margins around single restorations in anterior areas.
Methods: After 16 weeks of healing, implants (Osseospeed, Astra Tech Dental Implant) were positioned. Depending on the different fixture inclination and the thickness of buccal peri-implant soft tissue, abutment selection resulted in four groups: Group 1 (patients with zirconia ZirDesign(®) stock abutments), Group 2 (titanium stock TiDesign(®) abutments), Group 3 (zirconia cad-cam abutments), and Group 4 (titanium cad-cam abutments).
Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses.
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
May 2014
Purpose: The purpose of this study was to evaluate the three-dimensional radiographic changes of 100% anorganic bovine bone xenograft volume in a grafted maxillary sinus, based on a computerized analysis of cone-beam computed tomography (CBCT) scan.
Materials And Methods: A maxillary sinus augmentation procedure done with a lateral approach using 100% anorganic bovine bone was performed in 20 patients. A CBCT scan of the grafted area was taken immediately after the procedure (T1) and 8 to 9 months later (T2).