Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated.
View Article and Find Full Text PDFBackground: Left ventricular aneurysms (LVA) are serious complications of myocardial infarction, being divided into true and false type. The false one-pseudoaneurysm (PA), is a life-threatening condition that requires urgent treatment due to the high risk of rupture.
Case Presentation: An 84-year-old female presented with progressive heart failure symptoms.
Circulation
January 2021
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR.
Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry.
Objective: To evaluate the hemodynamic performance (i.e., gradients and paravalvular leakage [PVL]) of the new and experimental Braile Inovare® Proseal.
View Article and Find Full Text PDFObjectives: This study sought to evaluate SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) positioning using different strategies.
Background: Aortic valve-in-valve (ViV) is associated with high risk of elevated gradients.
Methods: S3 aortic ViV procedures in stented bioprostheses were studied.
Background: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS).
Objective: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before.
Objectives: Reoperative procedure for the treatment of a failed mitral bioprosthesis is associated with considerable risk. In some cases, mortality is high and might contraindicate the benefit of the procedure. The minimally invasive valve-in-valve (ViV) transcatheter mitral valve implant offers an alternative less-invasive approach, reducing morbidity and mortality.
View Article and Find Full Text PDFAims: Transcatheter aortic valve implantation has emerged as an alternative to conventional aortic valve replacement in high-risk patients. Diverse prostheses are currently under investigation. The aim of this study was the clinical, safety and efficacy assessment of Braile Inovare Transcatheter Aortic Prosthesis usage.
View Article and Find Full Text PDFDespite recent advances in acute heart failure treatment, actual results remain limited in refractory cardiogenic shock. Temporary ventricular assist devices have emerged as an alternative in this serious and challenging medical. The purpose of this communication is to present a case of refractory cardiogenic shock, underwent temporary left ventricular assistance device implantation, progressing to right ventricular failure and conversion to biventricular support.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
December 2013
A 60-year old male patient with multiple risk factors and two previous interventions over the mitral valve was admitted to the emergency unit with symptoms of cardiac failure. Initial examination revealed a competent mitral bioprosthesis with severe perivalvular mitral insufficiency. Based on previous experiences with transapical procedures, a transapical transcatheter closure of the perivalvular leak was performed.
View Article and Find Full Text PDFObjective: Heart failure is currently one of the most common hospitalization causes. Several chronic circulatory assist devices have been tested and are highly complex. The objective is the description of a pulsatile endoprosthesis capable of applying a chronic pulse within the descending aorta, similar to that produced by intra-aortic balloon.
View Article and Find Full Text PDFIntroduction: The cardiac bioprostheses are related to thromboembolic events, infectious and degenerative diseases. Wear is mainly attributed to the denaturation of collagen. Glutaraldehyde, the predominant method of preservation of bioprostheses, favors the calcification process and limits their durability.
View Article and Find Full Text PDFObjective: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure. Minimally invasive transcatheter aortic "valve-in-valve" implant appears to be an alternative, reducing morbidity and mortality.
View Article and Find Full Text PDFTricuspid valve disease is not uncommon. Some patients with tricuspid valve disease require tricuspid replacement with bioprosthesis and, over time, may require re-interventions. Transcatheter tricuspid valve-in-valve approach has emerged as an alternative to treat dysfunctional bioprosthesis.
View Article and Find Full Text PDFObjectives: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative.
View Article and Find Full Text PDFIntroduction: Patients with congenital heart disease who underwent pulmonary valvotomy or surgery to open the pulmonary valve ring are prone to develop residual pulmonary insufficiency or stenosis that may lead to right heart failure with clinical deterioration. These children require multiple interventions throughout their lives, which impose a high rate of morbidity and mortality.
Objective: To develop a less invasive technique for implantation of a valved prosthesis through the right ventricle.
Objective: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication. Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment.
View Article and Find Full Text PDFObjective: The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant.
View Article and Find Full Text PDFCoronary artery bypass graft (CABG) is a well established procedure with current precise indications. The advent and spread of this technique was possible after the introduction of the coronary angiogram. Although many evaluation methods have been developed in the past years, to date, none have been able to replace the invasive coronary angiogram as a pre-operative exam.
View Article and Find Full Text PDFObjective: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality.
View Article and Find Full Text PDFObjectives: To assess efficacy and safety of videothoracoscopic pericardial drainage in the treatment and diagnostic of pericardial effusion through 26 cases review.
Methods: From April 2005 to December 2007, 26 patients with pericardial effusion underwent a video-thoracoscopic pericardial window. Median age was 48.
Neoplasms are among the most common solid-organ transplant complications, occurring in 11.7% of all transplant recipients and in 6% to 15% of heart transplant recipients, according to early studies. The skin and lips are the most common sites for neoplasms, but they also appear in the setting of post-transplant lymphoproliferative disease.
View Article and Find Full Text PDF