Objective: To show the experience of a Latin American public hospital, with SNM in the management of either OAB, NOUR or FI, reporting feasibility, short to medium-term success rates, and complications.
Methods: A retrospective cohort was conducted using data collected prospectively from patients with urogynecological conditions and referred from colorectal surgery and urology services between 2015 and 2022.
Results: Advanced or basic trial phases were performed on 35 patients, 33 (94%) of which were successful and opted to move on Implantable Pulse Generator (GG) implantation.
Introduction: Both detrusor underactivity (DU) and bladder outlet obstruction (BOO) can coexist in patients with overactive bladder. Definitions of both DU and BOO are based on pressure-flow study (PFS) data. However, invasive urodynamics study can differ from a natural micturition, in fact, discrepancies between free uroflowmetry (UFM) and PFS have been largely described.
View Article and Find Full Text PDF