Background: A review of the literature revealed that only 9 total knee replacements were performed on patients with osteogenesis imperfecta (OI), with one being a revision procedure of a periprosthetic fracture. Of the 9 primary procedures, all used cemented prostheses, and 3 patients had an osteotomy at the same procedure. Our patient required a hinged prosthesis because of collateral ligament incompetence and is the first such case reported in the literature.
View Article and Find Full Text PDF»: Osteogenesis imperfecta (OI) is a rare congenital disorder that affects connective tissue.
»: Modern medicine has mitigated the mortality that is associated with OI, allowing patients to live a near-normal life span.
»: The degenerative process in OI is probably accelerated because of subclinical intra-articular fractures, joint laxity, and distorted femoral and acetabular anatomy.
This article serves to review the existing clinical guidelines, and highlight the most recent medical and surgical recommendations, for the management of displaced femoral neck fractures (FNFs). It stresses the need for multi-disciplinary intervention to potentially improve mortality rates, limit adverse events and prevent further economic liability.Globally, the incidence of FNFs continues to rise as the general population ages and becomes more active.
View Article and Find Full Text PDFBackground: Patients with HIV are more likely to require a total hip arthroplasty (THA) because of an increase in life expectancy and complications with HIV. The purpose of this study is to describe the mid-term outcomes of THA in HIV-positive patients and risk factors for postoperative infections and poor outcomes.
Methods: This is a single-center retrospective review of nonhemophiliac HIV-positive patients who underwent THA.
Background: Activity monitors have added a new dimension to our ability to objectively measure physical activity in patients undergoing total knee arthroplasty (TKA). The aim of the study is to assess whether changes in the time spent sitting, standing, and stepping were associated with changes in patient-reported outcome measures (PROMs) before and after TKA.
Methods: Valid activPAL data (>3 days) and PROMs were obtained from 49 men and women (mean [SD] age, 62.
Background: Modern management of human immunodeficiency virus (HIV) infection has afforded patients longevity while increasing the burden of arthroplasty procedures because of the increased risk of osteonecrosis, fragility fractures, and degenerative joint disease. Early publications on hip and knee arthroplasty in HIV-positive patients reported a high risk of complications, although some more recent publications demonstrated acceptable outcomes. Despite the widespread nature of the HIV pandemic, there is a paucity of literature addressing outcomes following joint arthroplasty in infected patients.
View Article and Find Full Text PDFBackground: Physical activity levels are decreased and sedentary behaviour levels are increased in patients with knee osteoarthritis (OA). However, previous studies have shown that following total knee arthroplasty (TKA), objectively measured physical activity levels do not change compared to before the surgery. Very few studies have objectively assessed sedentary behaviour following TKA.
View Article and Find Full Text PDFIn a randomized prospective study, we compared the use of tibial screws with screwless tibial baseplate fixation in uncemented total knee arthroplasty and report the results of 154 prostheses at a mean follow-up of 5 years. Patients were mobilized within 24 hours and continued with partial weight-bearing for up to 6 weeks postoperatively. There were no significant differences in radiologic results and revision rates.
View Article and Find Full Text PDFThe performance of novel ceramic-on-metal bearing couples has been compared with metal-on-metal and ceramic-on-ceramic bearing couples in laboratory and short-term clinical studies. Laboratory studies compared ceramic-on-metal with metal-on-metal and ceramic-on-ceramic bearings with diameters of 28 and 36 mm under standard conditions and under adverse conditions with head loading on the rim of the cup. Clinical studies compared metal ion levels in ceramic-on-metal with metal-on-metal, ceramic-on-ceramic, and ceramic-on-polyethylene bearings in a randomized prospective study.
View Article and Find Full Text PDF