Purpose: To determine the accuracy of a surface guided radiotherapy (SGRT) system for positioning of breast cancer patients in breath-hold (BH) with respect to cone-beam computed tomography (CBCT). Secondly, to evaluate the thorax position stability during BHs with SGRT, when using an air-volume guidance system.
Methods And Materials: Eighteen left-sided breast cancer patients were monitored with SGRT during CBCT and treatment, both in BH.
In 2005, we introduced hypofractionated 3-dimensional conformal radiotherapy with a simultaneous integrated boost (3D-CRT-SIB) technique after breast conserving surgery. In a consecutive series of 752 consecutive female invasive breast cancer patients (stages I-III) the 5-year actuarial rate for local control was 98.9%.
View Article and Find Full Text PDFPurpose: To evaluate toxicity and cosmetic outcome (CO) in breast cancer survivors treated with three-dimensional conformal radiotherapy with a hypofractionated, simultaneous integrated boost (3D-CRT-SIB) and to identify risk factors for toxicity, with special focus on the impact of age.
Methods And Materials: Included were 940 consecutive disease-free patients treated for breast cancer (Stage 0-III) with 3D-CRT-SIB, after breast-conserving surgery, from 2005 to 2010. Physician-rated toxicity (Common Terminology Criteria for Adverse Events version 3.
Purpose: To report on local control and survival after breast conserving therapy (BCT) including three-dimensional conformal simultaneous integrated boost irradiation (3D-CRT-SIB) and on the influence of age on outcome.
Patient And Methods: For this study, 752 consecutive female breast cancer patients (stages I-III), treated with 3D-CRT-SIB at the University Medical Center Groningen from 2005 to 2008, were retrospectively identified. Median age was 58.
Background And Purpose: To determine the consequences of target volume (TV) modifications, based on the additional use of PET information, on radiation planning, assuming PET/CT-imaging represents the true extent of the tumour.
Materials And Methods: For 21 patients with esophageal cancer, two separate TV's were retrospectively defined based on CT (CT-TV) and co-registered PET/CT images (PET/CT-TV). Two 3D-CRT plans (prescribed dose 50.