Deep Learning (DL) is becoming an increasingly popular technology being employed in life sciences research due to its ability to perform complex and time-consuming tasks with significantly greater speed, accuracy, and reproducibility than human researchers - allowing them to dedicate their time to more complex tasks. One potential application of DL is to analyze cell images taken by microscopes. Quantitative analysis of cell microscopy images remain a challenge - with manual cell characterization requiring excessive amounts of time and effort.

View Article and Find Full Text PDF

Introduction: A quantifiable, automated standard of analyzing heart rhythm has long eluded cardiologists due, in part, to the limitations in technology and the ability to analyze large electrogram datasets. In this proof-of-concept study, we propose new measures to quantify plane activity in atrial fibrillation (AF) using our Representation of Electrical Tracking of Origin (RETRO)-Mapping software.

Methods: We recorded 30 s segments of electrograms at the lower posterior wall of the left atrium using a 20-pole double loop catheter (AFocusII).

View Article and Find Full Text PDF

Tissue Doppler imaging is an essential echocardiographic technique for the non-invasive assessment of myocardial blood velocity. Image acquisition and interpretation are performed by trained operators who visually localise landmarks representing Doppler peak velocities. Current clinical guidelines recommend averaging measurements over several heartbeats.

View Article and Find Full Text PDF

Arterial stiffness and wave reflection are important components of the ventricular afterload. Therefore, we aimed to assess the arterial wave characteristics and mechanical properties of the proximal pulmonary arteries (PAs) in the hypoxic pulmonary hypertensive rat model. After 21 days in normoxic or hypoxic chambers (24 animals/group), animals underwent transthoracic echocardiography and PA catheterization with a dual-tipped pressure and Doppler flow sensor wire.

View Article and Find Full Text PDF

Aims: Measurements with superior reproducibility are useful clinically and research purposes. Previous reproducibility studies of Doppler assessment of aortic stenosis (AS) have compared only a pair of observers and have not explored the mechanism by which disagreement between operators occurs. Using custom-designed software which stored operators' traces, we investigated the reproducibility of peak and velocity time integral (VTI) measurements across a much larger group of operators and explored the mechanisms by which disagreement arose.

View Article and Find Full Text PDF

Background: Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain.

Methods And Results: We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames.

View Article and Find Full Text PDF

Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of ~8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers.

View Article and Find Full Text PDF

Objectives: To determine the optimal frame rate at which reliable heart walls velocities can be assessed by speckle tracking.

Background: Assessing left ventricular function with speckle tracking is useful in patient diagnosis but requires a temporal resolution that can follow myocardial motion. In this study we investigated the effect of different frame rates on the accuracy of speckle tracking results, highlighting the temporal resolution where reliable results can be obtained.

View Article and Find Full Text PDF

Background: Head-up tilt (HUT) is used for diagnosis of vasovagal syncope (VVS), and can provoke cardioinhibition. VVS is usually considered benign, however pacemaker insertion may be indicated in some patients. We sought to characterize the long-term outcomes of patients with prolonged asystole (>15s) on HUT.

View Article and Find Full Text PDF

Background: Cardiopulmonary exercise testing allows for assessment of cardiac and respiratory limitation, but is often affected by patient effort. Indices of oxygen kinetics, including the oxygen uptake efficiency slope (OUES), oxygen uptake-work-rate slope (VO-WR slope) and the heart rate-oxygen uptake slope (HR-VO slope) are relatively effort independent but may be affected by patient characteristics. The objective of this study is to identify the impact of factors, such as age, gender, body size, respiratory function, smoking and beta-blockade on these parameters, as well as generate predictive equations.

View Article and Find Full Text PDF

Obtaining a "correct" view in echocardiography is a subjective process in which an operator attempts to obtain images conforming to consensus standard views. Real-time objective quantification of image alignment may assist less experienced operators, but no reliable index yet exists. We present a fully automated algorithm for detecting incorrect medial/lateral translation of an ultrasound probe by image analysis.

View Article and Find Full Text PDF

Left ventricular function can be evaluated by qualitative grading and by eyeball estimation of ejection fraction (EF). We sought to define the reproducibility of these techniques, and how they are affected by image quality, experience and accreditation. Twenty apical four-chamber echocardiographic cine loops (Online Resource 1-20) of varying image quality and left ventricular function were anonymized and presented to 35 operators.

View Article and Find Full Text PDF

Objective: Aortic reservoir pressure indices independently predict cardiovascular events and mortality. Despite this, there has never been a study in humans to determine whether the theoretical principles of the mathematically derived aortic reservoir pressure (RP(derived)) and excess pressure (XP(derived)) model have a real physiological basis. This study aimed to directly measure the aortic reservoir (AR(direct); by cyclic change in aortic volume) and determine its relationship with RP(derived), XP(derived), and aortic blood pressure (BP).

View Article and Find Full Text PDF

In clinical practice, echocardiographers are often unkeen to make the significant time investment to make additional multiple measurements of Doppler velocity. Main hurdle to obtaining multiple measurements is the time required to manually trace a series of Doppler traces. To make it easier to analyze more beats, we present the description of an application system for automated aortic Doppler envelope quantification, compatible with a range of hardware platforms.

View Article and Find Full Text PDF

Background: Variability has been described between different echo machines and different modalities when measuring tissue velocities. We assessed the consistency of tissue velocity measurements across different modalities and different manufacturers in an in vitro model and in patients. Furthermore, we present freely available software tools to repeat these evaluations.

View Article and Find Full Text PDF

Background: The test-retest reliability for multiple cardiopulmonary exercise test (CPX) variables has not been compared in a single study and the influence of different diseases on test-retest reliability has not been examined. We investigated different measures of test-retest reliability for multiple variables and compared them by category of cardiac or respiratory disease.

Methods: Patients with chronic obstructive airways disease (n = 24), heart failure (n = 43), or severe mitral valve disease (n = 26) were recruited into a prospective study.

View Article and Find Full Text PDF

Background: Effective regurgitant orifice area (EROA) in mitral regurgitation (MR) is difficult to quantify. Clinically it is measured using the proximal isovelocity surface area (PISA) method, which is intrinsically not automatable, because it requires the operator to manually identify the mitral valve orifice. We introduce a new fully automated algorithm, ("AQURO"), which calculates EROA directly from echocardiographic colour M-mode data, without requiring operator input.

View Article and Find Full Text PDF

Background: Transmitral pulse wave (PW) Doppler and annular tissue Doppler velocity measurements provide valuable diagnostic and prognostic information. However, they depend on an echocardiographer manually selecting positions to make the measurements. This is time-consuming and open to variability, especially by less experienced operators.