Semmes-Weinstein monofilament (SWM) evaluation for protective sensation in diabetic feet is a widely used tool to guide patient care. Little evidence is available for alternative testing modalities for use when monofilament is not available or is deformed. Multiple varieties of intravenous angiocatheter tubing were subjected to biomechanical testing on a digital scale to assess the force generated once bending was observed by five independently tested raters.
View Article and Find Full Text PDFThis article summarizes the results of a comprehensive review of the literature on the use of negative pressure wound therapy with reticulated open cell foam (NPWT/ROCF) as delivered by V.A.C.